15
Views
10
CrossRef citations to date
0
Altmetric
Biomedical Essay

Tandem mass spectrometry: the tool of choice for diagnosing inborn errors of metabolism?

Pages 42-46 | Accepted 20 Sep 2001, Published online: 27 Oct 2016

References

  • Anon. Neonatal screening for inborn errors of metabolism: cost, yield and outcome Health Technol Assess 1997; 1(7): iii-iv.
  • Scriver CR, Beaudet AL, Sly WS, Valle D. The metabolic and molecular bases of inherited disease. 7th ed. New York; McGraw-Hill, 1995.
  • Anon. Neonatal screening for inborn errors of metabolism: a systematic review. Health Technol Assess 1997; 1(11): 9–36.
  • Guthrie R, Susi A. A simple phenylalanine method for detecting PKU in large populations of newborn infants. Pediatrics 1963; 32: 338–43.
  • Guthrie R. Screening for inborn errors of metabolism in the newborn infant – a multiple test program. Birth Defects (Orig Art Ser) 1968; 4: 92–8.
  • Dussault JH, Laberge C. Thyroxine determination in dried blood by radioimmunoassay: a screening method for neonatal hypothyroidism? Union Med Can 1973; 102: 2062.
  • Xu YY, Pettersson K et al. Simultaneous quadruple label fluorimetric immunoassay of thyroid stimulating hormone, 17 alpha progesterone, immunoreactive trypsin, and creatine kinase MM isoenzyme in dried blood spots. Clin Chem 1992; 38: 2038–43.
  • Dobrowolski SF, Banas RA, Naylor EW et al. DNA microarray technology for neonatal screening. Acta Paediatr (Suppl) 1999; 432: 61–4.
  • Shoemaker JD, Elliott W Automated screening of urine samples for carbohydrate, organic and amino acids after treatment with urease. J Chromatol 1991; 562: 125–38.
  • Bennett MJ, Green A, Pollitt RJ et al. The routine investigation of urinary organic acids in selected paediatric patients: results over 2.5 year period Ann Clin Biochem 1984; 21: 45–50.
  • Sweetman L. Newborn screening by tandem mass spectrometry (MS-MS). Clin Chem 1996; 42: 345–6.
  • Levy HL. Newborn screening by tandem mass spectrometry: a new era. Clin Chem 1998; 44: 2401–2.
  • Seashore MR Tandem spectrometry in newborn screening. Curr Opin Pediatr 1998; 10: 609–14.
  • Tanaka K, Budd MA, Effron ML et al. Isovaleric acidaemia. A new defect of leucine metabolism. Proc Natl Acad Sci USA 1966; 56: 236–42.
  • Chalmers RA, Lawson AM. Organic acids in man. London: Chapman and Hall, 1982.
  • Engel AG, Angelini C. Carnitine deficiency: human skeletal muscle and lipid storage myopathy. Science 1973; 179: 899.
  • Hunt DF, Giordani ABB, Rhodes G et al. Mixture analysis by triple quadrupole mass spectrometry: metabolic profiling of urinary carboxylic acids. Clin Chem 1982; 28: 2387–92.
  • Yergev AL, Liberato DJ, Millington DS. Thermospray liquid chromatography for the analysis of L-carnitine and its shortchain acyl derivatives. Ann Clin Biochem 1984; 139: 278–83.
  • Millington DS, Kodo N, Norwood DL et al. Tandem mass spectrometry: a new method for acylcarnitine profiling with potential for neonatal screening for inborn errors of metabolism. J Inherit Metab Dis 1990; 13: 321–4.
  • Chace DH, Hillman SL, Millington DS et al. Rapid diagnosis of maple syrup urine disease in bloodspots from newborns by tandem mass spectrometry. Clin Chem 1995; 41: 62–8.
  • Chace DH, Hillman SL, Millington DS et al. Rapid diagnosis of homocystinuria and other hypermethioninaemias from newborn’s bloodspots by tandem mass spectrometry. Clin Chem 1996; 42: 349–55.
  • Rashed MS, Ozand PT, Harrison ME et al. Electrospray tandem mass spectrometry in the diagnosis of organic acidaemias. Rapid Commun Mass Spectrom 1994; 8: 129–33.
  • Rashed MS, Ozand PT, Bucknall MP. Diagnosis of inborn errors of metabolism from bloodspots by acylcarnitines and amino acid profiling using automated electrospray tandem mass spectrometry. Paediatr Res 1995; 38: 324–31.
  • Rashed MS, Rahbeeni Z, Ozand PT. Applications of electrospray tandem mass spectrometry to neonatal screening. Semin Perinatol 1999; 2: 183–93.
  • Chace DH, DiPierna JC, Naylor EW. Laboratory integration and utilisation of tandem mass spectrometry in neonatal screening: a model for clinical mass spectrometry in the next millennium Acta Paediatr (Suppl) 1999; 432: 45–7.
  • Chace DH, Millington DS et al. Rapid diagnosis of phenylketonuria by quantitative analysis of phenylalanine and tyrosine in neonatal blood spots by tandem mass spectrometry. Clin Chem 1993; 39: 287–90.
  • Chace DH, Sherwin JE et al. Use of phenylalanine to tyrosine ratio determined by tandem mass spectrometry to improve newborn screening for phenylketonuria of early discharge specimens collected in the first 24 hours. Clin Chem 1998: 44: 2405–9.
  • Shigematsu Y, Hata I, Kikawa Y et al. Modifications in electrospray tandem mass spectrometry for a neonatal screening pilot study in Japan J Chromatogr B Biomed Sci Appl 1999; 731: 97–103.
  • Chace DH, Hillman SL, Van Hove JK, Naylor EW. Rapid diagnosis of MCAD deficiency. Quantitation of octanoylcarnitine and other acylcarnitines by MS/MS. Clin Chem 1997; 43: 2106.
  • Rashed MS, Bucknall MP et al. Screening blood spots for inborn errors of metabolism by electrospray tandem mass spectrometry with a microplate batch process and a computer algorithm for automated flagging of abnormal profiles. Clin Chem 1997; 43: 1129–41.
  • Iles V. Really managing healthcare. Open University Press: 1997.
  • Pollitt RJ. Principles and performance: assessing the evidence. Acta Paediatr (Suppl) 1999; 432: 110–4.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.