- Barber , C.B. , Dobkin , D.P. and Huhdanpaa , H.T. 1996 . The quickhull algorithm for convex hulls . ACM Trans. Math. Software , 22 ( 4 ) : 469 – 483 .
- Cootes , T.F. , Taylor , C.J. , Cooper , D.H. and Graham , J. 1995 . Active shape models—their training and application . Comput. Vision Image Und. , 61 ( 1 ) : 38 – 59 .
- R.H. Davies, “Learning shape: optimal models for analysing natural variability”, Dissertation University of Manchester, 2002.
- Davies , R.H. , Twining , C.J. , Cootes , T.F. , Waterton , J. and Taylor , C.J. 2002 . A minimum description length approach to statistical shape modelling . IEEE Trans. Med. Imaging , 21 : 525 – 537 .
- Hieu , L.C. , Bohez , E. , Vander Sloten , J. , Vatcharaporn , E. , Binh , P.H. , An , P.V. and Oris , P. 2003 . Design for medical rapid prototyping of cranioplasty implant . Rapid Prototyping J. , 9 ( 3 ) : 175 – 186 .
- Jans , G. , Vander Sloten , J. , Gobin , R. , Van der Perre , G. , Van Audekercke , R. and Mommaerts , M. 1999 . Computer-aided craniofacial surgical planning implemented in CAD software . Comput. Aided Surg. , 4 : 117 – 128 .
- Kass , M. , Witkin , A. and Terzopoulos , D. 1987 . Snakes: active contour models . Int. J. Comput. Vision , 1 ( 4 ) : 321 – 331 .
- Kaus , M.R. , Lorenz , C. , Truyen , R. , Lobregt , S. and Weese , J. 2003 . Automated 3D PDM construction from segmented images using deformable model . IEEE Trans. Med. Imaging , 22 ( 8 ) : 1005 – 1013 .
- Kozak , J. , Nesper , M. , Fischer , M. , Göggelmann , A. , Hassfeld , S. and Wetter , T. 2002 . Semiautomated registration using new markers for assessing the accuracy of a navigation system . Comput. Aided Eng. , 7 : 11 – 24 .
- Lorensen , W.E. and Cline , H.E. 1987 . Marching cubes: a high resolution 3D surface construction algorithm . Comput. Graph. , 21 ( 4 ) : 163 – 169 .
- McInerney , T. and Terzopoulos , D. 1996 . Deformable models in medical image analysis: a survey . Med. Image Anal. , 1 ( 2 ) : 91 – 108 .
- Mulier , J.C. , Mulier , M. , Brady , L.P. , Steenhoudt , H. , Cauwe , Y. , Goossens , M. and Elloy , M. 1989 . A new system to produce intraoperatively custom femoral prosthesis from measurements taken during the surgical procedure . Clin. Orthop. Relat. Res. , 249 : 97 – 112 .
- Pattijn , V. , Samson , I. , Vander Sloten , J. , Van Audekercke , R. , Swaelens , B. and De Buck , V. 2002 . Medical image based, preformed titanium membranes for bone reconstructions: design study and first clinical evaluation . Proc. Inst. Mech. Eng. H—J. Eng. Med. , 216 : 13 – 21 .
- Rajamani , K.T. , Joshi , S.C. and Styner , M.A. 2004 . “ Bone model morphing for enhanced surgical visualization ” . In IEEE Int. Symp. Biomed. Imaging 1255 – 1258 .
- Saxena , R. , Zachariah , S.G. and Sanders , J.E. 2002 . Processing computer tomography bone data for prosthetic finite element modeling . J. Rehabil. Res. Dev. , 39 ( 5 ) : 609 – 614 .
- Styner , M.A. , Rajamani , K.T. , Nolte , L-P. , Zsemlye , G. , Székely , G. , Taylor , C.J. and Davies , R.H. 2004 . Evaluation of 3D correspondence methods for model building . Inf. Process. Med. Imaging 2003 , : 63 – 75 .
- H. Van Oosterwyck, “Study of biomechanical determinants of bone adaptation around functionally loaded oral implants”. PhD thesis, Katholieke Universiteit Leuven, 2000.