References
- Alderliesten T, Konings MK, Niessen WJ. 2007. Modeling friction, intrinsic curvature, and rotation of guide wires for simulation of minimally invasive vascular interventions. IEEE Trans Biomed Eng. 54(1):29–38. doi:10.1109/TBME.2006.886659.
- Cotin S, Duriez C, Lenoir J, Neumann P, Dawson S. 2005. New approaches to catheter navigation for interventional radiology simulation. In: Proceedings of medical image computing and computer-assisted intervention. 2005 Oct 26–30, Palm Springs (USA), MICCAI; p. 534–542.
- Doyley MM. 2012. Model-based elastography: a survey of approaches to the inverse elasticity problem. Phys Med Biol. 57(3):R35–R73. doi:10.1088/0031-9155/57/3/R35.
- Fabbri R, Costa LF, Torelli JC, Bruno OM. 2008. 2d euclidean distance transform algorithms. ACM Comp Surv. 40(1):1–44. doi:10.1145/1322432.1322434.
- Fuster V, Kelly BB. 2010. Promoting cardiovascular health in the developing world: a critical challenge to achieve global health. Institute of Medicine (US) Committee on Preventing the Global Epidemic of Cardiovascular Disease: Meeting the Challenges in Developing Countries. Washington (DC): National Academies Press.
- Ganji Y, Janabi-Sharifi F. 2009. Catheter kinematics for intracardiac navigation. IEEE Trans Biomed Eng. 56(3):621–632. doi:10.1109/TBME.2009.2013134.
- Konings MK, Van de Kraats EB, Alderliesten T, Niessen WJ. 2003. Analytical guide wire motion algorithm for simulation of endovascular interventions. Med Biol Imag Comput. 41(6):689–700. doi:10.1007/BF02349977.
- Lenoir J, Cotin S, Duriez C, Neumann P. 2006. Interactive physically-based simulation of catheter and guidewire. Comput Graph. 30(3):416–422. doi:10.1016/j.cag.2006.02.013.
- Lobregt S, Viergever MA. 1995. A discrete dynamic contour model. IEEE Trans Med Imag. 14(1):12–24. doi:10.1109/42.370398.
- Luboz V, Zhai J, Littler P, Gould D, Hot T, Bello F. 2011. Simulation of endovascular guidewire behaviour and experimental validation. Comput Methods Biomec Biomed Eng. 14(6):515–520. doi:10.1080/10255842.2010.484003.
- Luo M, Xie H, Xie L, Cai P, Gu L. 2014. A robust and real-time vascular intervention simulation based on Kirchhoff elastic rod. Comput Med Imag Graph. 38(8):735–743. doi:10.1016/j.compmedimag.2014.08.002.
- Moraes MC, Furuie SS. 2011. Automatic coronary wall segmentation in intravascular ultrasound images using binary morphological reconstruction. Ultrasound Med Biol. 37(9):1486–1499. doi:10.1016/j.ultrasmedbio.2011.05.018.
- Schafer S, Singh V, Noël PB, Walczak AM, Xu J, Hoffmann KR. 2009. Real-time endovascular guidewire position simulation using shortest path algorithms. Int J Comput Assist Radiol Surg. 4(6):597–608. doi:10.1007/s11548-009-0385-z.
- Tang W, Wan TR, How T, John NW. 2012. A stable and real-time nonlinear elastic approach to simulating guidewire and catheter insertions based on Cosserat rod. IEEE Trans Biomed Eng. 59(8):2211–2218. doi:10.1109/TBME.2012.2199319.
- Terzopoulos D, Fleischer K. 1988. Deformable models. Visual Comput. 4(6):306–331. doi:10.1007/BF01908877.
- Wahle A, Prause G, Dejong S, Sonka M. 1999. Geometrically correct 3-D reconstruction of intravascular ultrasound images by fusion with biplane angiography-methods and validation. IEEE Trans Med Imag. 18(8):686–699. doi:10.1109/42.796282.