References
- Ao J, Li T, Liu Y, Ding Y, Wu G, Hu K, Kong L. 2010. Optimal design of thread height and width on an immediately loaded cylinder implant: a finite element analysis. Comput Biol Med. 40:681–686.10.1016/j.compbiomed.2009.10.007
- Brunski JB, Puleo DA, Nanci A. 2000. Biomaterials and biomechanics of oral and maxillofacial implants: current status and future developments. Int J Oral Maxillofac Implants. 15:15–46.
- Figliuzzi M, Mangano F, Mangano C. 2012. A novel root analogue dental implant using CT scan and CAD/CAM: selective laser melting technology. Int J Oral Maxillofac Surg. 41:858–862.10.1016/j.ijom.2012.01.014
- Grant JA, Bishop NE, Gotzen N, Sprecher C. 2007. Artificial composite bone as a model of human trabecular bone: the implant–bone interface. J Biomech. 40:1158–1164.
- Hasan I, Bourauel C, Keilig L, Reimann S, Heinemann F. 2011. The influence of implant number and abutment design on the biomechanical behaviour of bone for an implant-supported fixed prosthesis: a finite element study in the upper anterior region. Comput Method Biomech Biomed Eng. 14:1113–1116.10.1080/10255842.2010.515212
- Huang HL, Hsu JT, Fuh LJ, Tu MG, Ko CC, Shen YW. 2008. Bone stress and interfacial sliding analysis of implant designs on an immediately loaded maxillary implant: a non-linear finite element study. J Dent. 36:409–417.10.1016/j.jdent.2008.02.015
- Javed F, Romanos GE. 2010. The role of primary stability for successful immediate loading of dental implants. a literature review. J Dent. 38:612–620.
- Joo-Ho Choi BL, Han JS. 2001. Boundary integral method for shape optimization of interface problems and its application to implant design in dentistry. Comput Methods Appl Mech Eng. 190:6906–6926.
- Kim JH, Lee JG, Han DH, Kim HJ. 2011. Morphometric analysis of the anterior region of the maxillary bone for immediate implant placement using micro-CT. Clin Anat. 24:462–468.10.1002/ca.v24.4
- Koh RU, Rudek I, Wang HL. 2010. Immediate implant placement: positives and negatives. Implant Dent. 19:98–108.10.1097/ID.0b013e3181d47eaf
- Kohal RJ, Klaus G, Strub JR. 2002. Clinical investigation of a new dental immediate implant sysytem. The reimplant®-system. Dtsche Zahnärztl Z. 5:495–497.
- Lundgren D, Rylander H, Anderssong M, Johansson C, Albrektsson T. 1992. Healing-in of root analogue titanium implants placed in extraction sockets. An experimental study in the beagle dog. Clin Oral Implants Res. 3:136–144.10.1034/j.1600-0501.1992.030306.x
- Mangano FG, Cirotti B, Sammons RL, Mangano C. 2012. Custom-made, root-analogue direct laser metal forming implant: a case report. Lasers Med Sci. 27:1241–1245.10.1007/s10103-012-1134-z
- Mangano FG, De Franco M, Caprioglio A, Macchi A, Piattelli A, Mangano C. 2013. Immediate, non-submerged, root-analogue direct laser metal sintering (DLMS) implants: a 1-year prospective study on 15 patients. Lasers Med Sci. 29:1321–1328.
- Nakano YYYI. 2012. Influences of implant neck design and implant-abutment joint type on peri-implant bone stress and abutment micromovement: three-dimensional finite element analysis. Dent Mater. 28:1126–1133.
- Nowzari H, Molayem S, Chiu CH, Rich SK. 2010. Cone beam computed tomographic measurement of maxillary central incisors to determine prevalence of facial alveolar bone width ≥2 mm. Clin Implant Dent Relat Res. 14:595–602.10.1111/j.1708-8208.2010.00287.x
- Oshida Y, Tuna EB, Aktören O, Gençay K. 2010. Dental implant systems. Int J Mol Sci. 11:1580–1678.10.3390/ijms11041580
- Pirker W, Kocher A. 2008. Immediate, non-submerged, root-analogue zirconia implant in single tooth replacement. Int J Oral Maxillofac Surg. 37:293–295.10.1016/j.ijom.2007.11.008
- Pirker W, Kocher A. 2009. Immediate, non-submerged, root-analogue zirconia implants placed into single-rooted extraction sockets: 2-year follow-up of a clinical study. Int J Oral Maxillofac Surg. 38:1127–1132.10.1016/j.ijom.2009.07.008
- Pirker W, Kocher A. 2011. Root analog zirconia implants: true anatomical design for molar replacement–a case report. Int J Periodontics Restorative Dent. 31:663–668.
- Pirker W, Wiedemann D, Lidauer A, Kocher AA. 2011. Immediate, single stage, truly anatomic zirconia implant in lower molar replacement: a case report with 2.5 years follow-up. Int J Oral Maxillofac Surg. 40:212–216.10.1016/j.ijom.2010.08.003
- Razzouk S. 2010. Bone remodeling and individual-based implant therapy. N Y State Dent J. 76:39–41.
- Sadrimanesh R, Siadat H, Sadr-Eshkevari P, Monzavi A, Maurer P, Rashad A. 2012. Alveolar bone stress around implants with different abutment angulation: an FE-analysis of anterior maxilla. Implant Dent. 21:196–201.10.1097/ID.0b013e31824c302e
- Steigenga JT, al-Shammari KF, Nociti FH, Misch CE, Wang HL. 2003. Dental implant design and its relationship to long-term implant success. Implant Dent. 12:306–317.10.1097/01.ID.0000091140.76130.A1
- Strub JR, Jurdzik BA, Tuna T. 2012. Prognosis of immediately loaded implants and their restorations: a systematic literature review. J Oral Rehabil. 39:704–717.10.1111/joor.2012.39.issue-9
- Xianshuai Chen LX, Jianyu Chen RD, Deng F. 2012. Design and fabrication of custom-made dental implants. J Mech Sci Technol. 26:1–6.
- Yongki Yoon XS, Jen-Kuang Huang GH, Rechowicz K. 2013. Designing natural-tooth-shaped dental implants based on soft-kill option optimization. Comput Aided Des Appl. 10:59–72.10.3722/cadaps.2013.59-72