715
Views
154
CrossRef citations to date
0
Altmetric
Original Articles

Analytical Applications of Solid and Paste Amalgam Electrodes

&
Pages 189-203 | Published online: 08 Jul 2009

REFERENCES

  • Yosypchuk , B. and Novotný , L. 2002 . Nontoxic electrodes of solid amalgams . Crit. Rev. Anal. Chem. , 32 : 141 – 151 .
  • Cooper , W. C. 1955 . The polarographic behavior of dropping tin amalgam electrodes . J. Am. Chem. Soc. , 77 : 2074 – 2076 .
  • Stojek , Z. and Kublik , Z. 1975 . Silver based mercury film electrode: I. General characteristics and stability of the electrode . J. Electroanal. Chem. , 60 : 349 – 358 .
  • Ciszkowska , M. , Donten , M. and Stojek , Z. 1994 . Preparation of a mercury disk microelectrode based on solid silver amalgam . Anal. Chem. , 66 : 4112 – 4115 .
  • Kapturski , P. and Bobrowski , A. 2007 . Silver amalgam film electrode of prolonged application in stripping chronopotentiometry . Electroanalysis , 19 : 1863 – 1868 .
  • Piech , R. , Bas , B. , Niewiara , E. and Kubiak , W. W. 2008 . Renewable copper and silver amalgam film electrodes of prolonged application for the determination of elemental sulfur using stripping voltammetry . Electroanalysis , 20 : 809 – 815 .
  • Novotný , L. , Havran , L. , Josypchuk , B. and Fojta , M. 2000 . Adsorptive stripping voltammetry of denatured DNA on Hg/Ag Electrode . Electroanalysis , 12 : 960 – 962 .
  • O'Shea , T. J. and Lunte , S. M. 1993 . Selective detection of free thiols by capillary electrophoresis-electrochemistry using a gold/mercury amalgam microelectrode . Anal. Chem. , 65 : 247 – 250 .
  • Bjorefors , F. and Nyholm , L. 1996 . Stripping voltammetry at preplated mercury coated microelectrodes in flowing solutions . Anal. Chim. Acta , 325 : 11 – 24 .
  • Baranski , A. S. 1987 . Rapid anodic stripping analysis with ultramicroelectrodes . Anal. Chem. , 59 : 662 – 666 .
  • Kounaves , S. P. and Buffle , J. 1987 . An iridium-based mercury-film electrode: Part I. Selection of substrate and preparation . J. Electroanal. Chem. , 216 : 53 – 69 .
  • Kounaves , S. P. and Buffle , J. 1988 . An iridium based mercury film electrode: Part II. Comparison of mercury-film electrode behaviors: Theory versus reality . J. Electroanal. Chem. , 239 : 113 – 123 .
  • Donten , M. and Kublik , Z. 1986 . Application of a copper-based mercury film electrode in cathodic stripping voltammetry . Anal. Chim. Acta. , 185 : 209 – 218 .
  • Donten , M. and Kublik , Z. 1985 . General characteristics of the copper-based mercury film electrode . J. Electroanal. Chem. , 196 : 275 – 290 .
  • Acciari , H. A. , Codaro , E. N. and Guastaldi , A. C. 1998 . A comparative study of the corrosion of high copper dental amalgams . Materials Letters , 36 : 148 – 151 .
  • Mikkelsen , Ø. and Schrøder , K. H. 2002 . Voltammetry using a dental amalgam electrode for heavy metal monitoring of wines and spirits . Anal. Chim. Acta , 458 : 249 – 256 .
  • Yosypchuk , B. , Heyrovský , M. , Palecek , E. and Novotný , L. 2002 . Use of solid amalgam electrodes in nucleic acid analysis . Electroanalysis , 14 : 1488 – 1493 .
  • Yosypchuk , B. and Novotný , L. 2002 . Electrodes of non-toxic solid amalgams for electrochemical measurements . Electroanalysis , 14 : 1733 – 1738 .
  • Yosypchuk , B. , Navratil , T. , Barek , J. , Peckova , K. and Fischer , J. 2008 . “ Amalgam electrodes as sensors in the analysis of aquatic systems ” . In Progress on Drinking Water Research , Edited by: Lefebvre , M. H. and Roux , M. M. New York, USA : Nova Publishers .
  • Fadrná , R. 2005 . Polished silver solid amalgam electrode: Further characterization and applications in voltammetric measurements . Anal. Let. , 37 : 3251 – 3266 .
  • Wang , J. 1985 . Stripping Analysis , Deerfield Beach, USA : VCH .
  • Yosypchuk , B. Preparation and properties of mercury films on solid amalgam surface . Modern Electroanalytical Methods. 28th International Conference . Jetřichovice, Czech Republic. pp. 130 – 136 .
  • Yosypchuk , B. and Fojta , M. 2009 . Preparation and properties of mercury film electrodes on solid amalgam surface . Electroanalysis , submitted
  • Vries , W. T. D. and v. Dalen , E. 1967 . Linear potential-sweep voltammetry at a plane mercury-film electrode . J. Electroanal. Chem. , 14 : 315 – 327 .
  • Petersen , S. L. and Tallman , D. E. 1988 . Silver composite electrode for voltammetry . Anal. Chem. , 60 : 82 – 86 .
  • Navratil , T. and Kopanica , M. 2002 . Analytical application of silver composite electrode . Crit. Rev. Anal. Chem. , 32 : 153 – 166 .
  • Navratil , T. , Senholdova , Z. , Shanmugam , K. and Barek , J. 2006 . Voltammetric determination of phenylglyoxylic acid in urine using graphite composite electrode . Electroanalysis , 18 : 201 – 206 .
  • Navratil , T. and Barek , J. 2009 . Analytical applications of composite solid electrodes . Crit. Rev. Anal. Chem. , in press
  • Yosypchuk , B. , Navrátil , T. , Lukina , A. N. , Pecková , K. and Barek , J. 2007 . Solid amalgam composite electrode as a new sensor for the determination of biologically active compounds . Chem. Anal. (Warsaw) , 52 : 897 – 910 .
  • Navrátil , T. , Yosypchuk , B. and Barek , J. 2008 . “ The use of composite electrodes in the analysis of drinking water ” . In Progress on Drinking Water Research , Edited by: Lefebvre , M. H. and Roux , M. M. New York, USA : Nova Publishers .
  • Da[nbreve]hel , A. , Yosypchuk , B. , Vyskočil , V. and Barek , J. New silver solid amalgam paste electrode for environmental application . 6th Spring Meeting of the International Society of Electrochemistry . Foz do Iguaçu, Brazil. pp. 131
  • Da[nbreve]hel , A. , Barek , J. , Yosypchuk , B. and Vyskočil , V. Voltammetric determination of genotoxic nitrocompounds using silver amalgam electrodes . 11th International Conference “Chemistry, Environment & Human Activity in Civilization Development,” . Toruń, Poland. pp. 138
  • Švancara , I. , Vytřas , K. , Barek , J. and Zima , J. 2001 . Carbon paste electrodes in modern electroanalysis . Crit. Rev. Anal. Chem. , 31 : 311 – 345 .
  • Yosypchuk , B. Working electrodes from paste amalgams . Modern Electroanalytical Methods. 27th International Conference . Jetřichovice, Czech Republic. pp. 181 – 185 .
  • Yosypchuk , B. and Šestáková , I. 2008 . Working electrodes from amalgam paste for electrochemical measurements . Electroanalysis , 20 : 426 – 433 .
  • Niaz , A. , Fischer , J. , Barek , J. , Yosypchuk , B. , Sirajuddin and Bhanger , M. I. Voltammetric determination of 4-nitrophenol using novel type of silver amalgam paste electrode . Electroanalysis , in press
  • Yosypchuk , B. , Barek , J. and Fojta , M. 2006 . Carbon powder based films on traditional solid electrodes as an alternative to disposable electrodes . Electroanalysis , 18 : 1126 – 1130 .
  • Jiránek , I. , Barek , J. and Yosypchuk , B. 2008 . The use of non-traditional carbon film electrode for voltammetric determination of 8-aminoquinoline . Chem. Listy , 102 : 101 – 102 .
  • Yosypchuk , B. and Novotný , L. 2004 . Reference electrodes based on solid amalgams . Electroanalysis , 16 : 238 – 241 .
  • Yosypchuk , B. and Novotný , L. 2003 . Mercurous sulfate reference electrode based on solid silver amalgam . Chem. Listy , 97 : 1083 – 1086 .
  • Yosypchuk , B. and Novotný , L. 2002 . The arrangement of a combined voltammetric-potentiometric sensor with the solid silver amalgam bridge . Chem. Listy , 96 : 886 – 888 .
  • Yosypchuk , B. and Novotný , L. 2002 . Combined voltammetric-potentiometric sensor with silver solid amalgam link for electroanalytical measurements . Electroanalysis , 14 : 1739 – 1741 .
  • Yosypchuk , B. and Novotný , L. 2002 . Determination of iodates using silver solid amalgam electrodes . Electroanalysis , 14 : 1138 – 1142 .
  • Yosypchuk , B. and Novotný , L. 2002 . Voltammetric determination of Cu, Pb, Cd, Zn and Tl using silver solid amalgam electrode . Chem. Listy , 96 : 756 – 760 .
  • Yosypchuk , B. and Novotný , L. 2003 . Copper solid amalgam electrodes . Electroanalysis , 15 : 121 – 125 .
  • Yosypchuk , B. , Šestáková , I. and Novotný , L. 2003 . Voltammetric determination of phytochelatins using copper solid amalgam electrode . Talanta , 59 : 1253 – 1258 .
  • Yosypchuk , B. 2003 . Electrodes of non-toxic solid amalgams for electrochemical measurements , Ph.D. Thesis Pardubice, Czech Republic : University of Pardubice .
  • Yosypchuk , B. and Novotný , L. Anodic stripping voltammetry of iron on polished silver solid amalgam electrode . Modern Electroanalytical Methods. 24th International Conference . Jetřichovice, Czech Republic. pp. 68
  • Lesven , L. , Skogvold , S. M. , Mikkelsen , Ø. and Billona , G. 2009 . Determination of manganese in natural media by anodic stripping voltammetry using a rotating solid silver amalgam electrode . Electroanalysis , 21 : 274 – 279 .
  • Fadrná , R. , Yosypchuk , B. , Fojta , M. , Navrátil , T. and Novotný , L. 2004 . Voltammetric determination of adenine, guanine, and DNA using liquid mercury free polished silver solid amalgam electrode . Anal. Let. , 37 : 399 – 413 .
  • Haso[nbreve] , S. , Simonaho , S.-P. , Silvennoinen , R. and Vetterl , V. 2004 . Detection of phase transients in two-dimensional adlayers of adenosine at the solid amalgam electrode surfaces . J. Electroanal. Chem. , 568 : 65 – 77 .
  • Haso[nbreve] , S. and Vetterl , V. 2004 . Application of thin film mercury electrodes and solid amalgam electrodes in electrochemical analysis of the nucleic acids components: Detection of the two-dimensional phase transients of adenosine . Bioelectrochemistry , 63 : 37 – 41 .
  • Haso[nbreve] , S. and Vetterl , V. 2006 . Microanalysis of oligodeoxynucleotides by cathodic stripping voltammetry at amalgam-alloy surfaces in the presence of copper ions . Talanta , 69 : 572 – 580 .
  • Haso[nbreve] , S. and Vetterl , V. 2006 . Detection of synthetic oligonucleotides by alternating current voltammetry at solid amalgam surfaces . Electrochim. Acta , 51 : 5199 – 5205 .
  • Jelen , F. , Yosypchuk , B. , Kourilova , A. , Novotný , L. and Paleček , E. 2002 . Label-free determination of picogram quantities of DNA by stripping voltammetry with solid copper amalgam or mercury electrodes in the presence of copper . Anal. Chem. , 74 : 4788 – 4793 .
  • Yosypchuk , B. , Fojta , M. , Havran , L. , Heyrovský , M. and Paleček , E. 2006 . Voltammetric behavior of osmium-labeled DNA at mercury meniscus-modified solid amalgam electrodes. Detecting DNA hybridization . Electroanalysis , 18 : 186 – 194 .
  • Fadrná , R. , Cahová-Kuchaříková , K. , Havran , L. , Yosypchuk , B. and Fojta , M. 2005 . Use of polished and mercury film-modified silver solid amalgam electrodes in electrochemical analysis of DNA . Electroanalysis , 17 : 452 – 459 .
  • Kuchaříková , K. , Novotný , L. , Yosypchuk , B. and Fojta , M. 2004 . Detecting DNA damage with a silver solid amalgam electrode . Electroanalysis , 16 : 410 – 414 .
  • Yosypchuk , B. and Novotný , L. 2002 . Cathodic stripping voltammetry of cysteine using silver and copper solid amalgam electrodes . Talanta , 56 : 971 – 976 .
  • Šelešovská-Fadrná , R. , Fojta , M. , Navrátil , T. and Chýlková , J. 2007 . Brdička-type processes of cysteine and cysteine-containing peptides on silver amalgam electrodes . Anal. Chim. Acta , 582 : 344 – 352 .
  • Yosypchuk , B. and Barek , J. 2009 . Properties of solid and paste amalgam electrodes which are different from metal mercury electrodes . Chem. Listy , 103 : 284 – 290 .
  • Pecková , K. 2006 . A contribution to the determination of nitro, amino, and hydroxy derivatives of naphthalene using electrochemical methods , Ph.D. Thesis Prague : Charles University in Prague, Faculty of Science, Department of Analytical Chemistry .
  • Daňhel , A. , Pecková , K. , Čížek , K. , Barek , J. , Zíma , J. , Yosypchuk , B. and Navrátil , T. 2007 . Voltammetric determination of genotoxic dinitronaphthalenes with mercury meniscus-modified silver solid amalgam electrode . Chem. Listy , 101 : 144 – 149 .
  • Vaňková , L. , Maixnerová , L. , Čížek , K. , Fischer , J. , Barek , J. , Navrátil , T. and Yosypchuk , B. 2006 . Voltammetric determination of submicromolar concentrations of 3-nitrofluoranthene and pendimethalin at silver solid amalgam electrode . Chem. Listy , 100 : 1105 – 1110 .
  • Barek , J. , Fischer , J. , Navratil , T. , Peckova , K. and Yosypchuk , B. 2006 . Silver solid amalgam electrodes as sensors for chemical carcinogens . Sensors , 6 : 445 – 452 .
  • Jirák , J. 2008 . Voltammetric determination of genotoxic 2-nitrofluorene at mercury meniscus modified silver solid amalgam electrode , B.Sc. Thesis Prague : Charles University in Prague .
  • Fischer , J. , Vanourkova , L. , Danhel , A. , Vyskocil , V. , Cizek , K. , Barek , J. , Peckova , K. , Yosypchuk , B. and Navratil , T. 2007 . Voltammetric determination of nitrophenols at a silver solid amalgam electrode . Int. J. Electrochem. Sci. , 2 : 226 – 234 .
  • Danhel , A. , Shiu , K. K. , Yosypchuk , B. , Barek , J. , Peckova , K. and Vyskocil , V. 2009 . The Use of silver solid amalgam working electrode for determination of nitrophenols by HPLC with electrochemical detection . Electroanalysis , 21 : 303 – 308 .
  • Fischer , J. , Va[nbreve]ourková , L. , Barek , J. , Navrátil , T. , Novotný , L. , Yosypchuk , B. and Zima , J. 2004 . Voltammetric determination of selected agrochemicals on silver solid amalgam electrode . Chem. Listy , 98 : 612 – 613 .
  • Jiranek , I. , Peckova , K. , Kralova , Z. , Moreira , J. C. and Barek , J. 2009 . The use of silver solid amalgam electrode for voltammetric and amperometric determination of nitroquinolines . Electrochim Acta , 54 : 1939 – 1947 .
  • Charvátová , M. 2007 . Voltammetric determination of 2-methoxy-5-nitrofenol on silver solid amalgam electrode , B. S. Thesis Prague : Charles University in Prague .
  • Fischer , J. , Barek , J. , Yosypchuk , B. and Navrátil , T. 2006 . Voltammetric determination of trace amounts of 2-methyl-4,6-dinitrophenol at a silver solid amalgam electrode . Electroanalysis , 18 : 127 – 130 .
  • Novotný , V. 2008 . Voltammetric and amperometric determination of acilfluorfen, nitrofen and oxyfluorfen , Diploma Thesis Prague : Charles University in Prague .
  • Cabalková , D. 2008 . Voltammetric determination of bifenox with silver solid amalgam electrode , Diploma Thesis Prague : Charles University in Prague .
  • De Souza , D. , de Toledo , R. A. , Mazo , L. H. and Machado , S. A. S. 2005 . Utilization of a copper solid amalgam electrode for the analytical determination of atrazine . Electroanalysis , 17 : 2090 – 2094 .
  • De Souza , D. , de Toledo , R. A. , Galli , A. , Salazar-Banda , G. R. , Silva , M. R. C. , Garbellini , G. S. , Mazo , L. H. , Avaca , L. A. and Machado , S. A. S. 2007 . Determination of triazine herbicides: development of an electroanalytical method utilizing a solid amalgam electrode that minimizes toxic waste residues, and a comparative study between voltammetric and chromatographic techniques . Anal. Bioanal. Chem. , 387 : 2245 – 2253 .
  • De Souza , D. , de Toledo , R. A. , Suffredini , H. B. , Mazo , L. H. and Machado , S. A. S. 2006 . Characterization and use of copper solid amalgam electrode for electroanalytical determination of triazines-based herbicides . Electroanalysis , 18 : 605 – 612 .
  • Konečná , B. 2005 . Voltammetric determination of doxorubicin at silver solid amalgam electrode , Diploma Thesis Prague : Charles University in Prague .
  • Vrzalová , L. 2007 . Voltammetric determination of carmustin at silver solid amalgam electrode , B. S. Thesis Prague : Charles University in Prague .
  • Radová , J. 2008 . Voltammetric determination of flutamid at silver solid amalgam electrode , B. S. Thesis Prague : Charles University in Prague .
  • Fultnerová , Z. 2008 . Voltammetric determination of antitumor drug lomustine at silver solid amalgam electrode , B. S. Thesis Prague : Charles University in Prague .
  • Čížková , P. , Navrátil , T. , Šestáková , I. and Yosypchuk , B. 2007 . Verification of applicability of solid amalgam electrode for determination of heavy metals in plant matrices . Electroanalysis , 19 : 161 – 171 .
  • Fojta , M. 2002 . Electrochemical sensors for DNA interaction and damage . Electroanalysis , 14 : 1449 – 1463 .
  • Ostatná , V. , Jelen , F. , Hianik , T. and Palecek , E. 2005 . Electrochemical responses of thiolated oligodeoxynucleotides in cobalt-containing solutions . Electroanalysis , 17 : 1413 – 1420 .
  • Fadrná , R. 2003 . Study of the interactions between hydroxyl radicals and purine DNA bases . Chem. Listy , 97 : 964 – 969 .
  • Kizek , R. , Havran , L. , Kubičárová , T. , Yosypchuk , B. and Heyrovský , M. 2002 . Voltammetry of two single-stranded isomeric end-labeled -SH deoxyoligonucleotides on mercury electrodes . Talanta , 56 : 915 – 918 .
  • Heyrovsky , M. 2005 . “ Catalytic hydrogen evolution at mercury electrodes from solutions of peptides and proteins ” . In Electrochemistry of Nucleic Acids and Proteins. Towards Electrochemical Sensors for Genomics and Proteomics , Edited by: Palecek , E. , Scheller , F. and Wang , J. 657 – 687 . Amsterdam : Elsevier .
  • Finklea , H. O. 1996 . “ Electrochemistry of organic monolayers of thiols and related molecules on electrodes ” . In Electroanalytical Chemistry , Edited by: Bard , A. J. and Rubinstein , I. 109 – 335 . New York : Marcel Dekker .
  • Barek , J. , Fischer , J. , Navrátil , T. , Pecková , K. , Yosypchuk , B. and Zima , J. 2007 . Nontraditional electrode materials in environmental analysis of biologically active organic compounds . Electroanalysis , 19 : 2003 – 2014 .
  • Barek , J. , Peckova , K. and Vyskocil , V. 2008 . Adsorptive stripping voltammetry of environmental carcinogens . Current Analytical Chemistry , 4 : 242 – 249 .
  • Pecková , K. , Barek , J. , Čížek , K. , Jiránek , I. and Zima , J. 2007 . “ Amperometric determination of genotoxic substances in flowing systems using novel electrode materials ” . In Sensing in Electroanalysis , Edited by: Vyt[rbreve]as , K. and Kalcher , K. 209 – 216 . Pardubice, Czech Republic : University of Pardubice .
  • Danhel , A. , Yosypchuk , B. and Barek , J. Single crystal silver amalgam microelectrodes . Modern Electroanalytical Methods. 29th International Conference . Jet[rbreve]ichovice, Czech Republic. pp. 15 – 16 .

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.