References
- Chang T MSC. Blood substitutes: Principles, Methods, Products and Clinical Trials. S Karger AG. 1997; Vol. 1
- Feola M, Simoni J, Canizaro P C, Tran R, Raschbaum G, Behal F J. Toxicity of polymerized hemoglobin solutions. Surg Gynec Obstet 1988; 166: 211–222
- White C T, Murray A J, Greene J R, Smith D J, Medina F, Makovec G T, Martin E J, Bolin R B. Toxicity of human hemoglobin solution infused into rabbits. J Lab Clin Med 1986; 108: 121–131
- Vogel W M, Lieberthal W, Apstein C S, Levinsky N, Valeri C R. Effects of stroma-free hemoglobin solutions on isolated perfused rabbit hearts and isolated perfused rat kidneys. Blood Substitutes, T M S Chang, R P Geyer. Marcel Dekker, Inc., New York, NY 1988; 227–236
- DeVenuto F. Hemoglobin solutions as oxygen-delivering resuscitation fluids. Crit Care Med 1982; 10: 238–245
- Weinstein M B, Segal H L. Uptake of free hemoglobin by rat liver parenchymal cells. Biochem Biophys Res Commun 1984; 123: 489–496
- Devenuto F, Friedman H I, Neville J R, Peck C C. Appraisal of hemoglobin solution as a blood substitute. Surg Gynec Obstet 1979; 149: 417–436
- Greenburg A G, Peskin G W, Hoyt D B, Moores W Y. Is it necessary to improve the intravascular retention of hemoglobin solutions?. Crit Care Med 1982; 10: 266–269
- Kahn R A, Allen R W, Baldassare J. Alternate sources and substitutes for therapeutic blood components. Blood 1985; 66: 1–12
- Blakney G B, Dinwoodie A J. A spectrophotometric scanning technique for the rapid determination of plasma hemoglobin. Clin Biochem 1975; 8: 96–102
- Bunn H F, Esham W T, Bull R W. The renal handling of hemoglobin. I. Glomerular filtration. J Exp Med 1969; 129: 909–924
- DeVenuto F, Moores W Y, Zegna A I, Zuck T F. Total and partial blood exchange in the rat with hemoglobin prepared by crystallization. Transfusion 1977; 17: 555–562
- DeVenuto F, Zegna A. Blood exchange with pyridoxalated and polymerized hemoglobin solution. Surg Gynec Obstet 1982; 155: 342–346
- Keipert P E, Chang T M S. Effects of partial and total isovolemic exchange transfusion in fully conscious rats using pyridoxylated polyhemoglobin solution as a colloidal oxygen-delivering blood replacement fluid. Vox Sang 1987; 53: 7–14
- Hess J, Fadare S, Tolentino L, Bengal N. The intravascular persistence of DBBF-hemoglobin. Seventh International Conference on Red Cells. Metabolism and Function, Ann Arbor, MI, 1988, (Abstract 19)
- Velky T S, Jr., Lee E S, Maffuid P W, Robinson G T, Yang J C, Greenburg A G. Peritoneal accumulation of infused stroma-free hemoglobin. Arch Surg 1987; 122: 355–357
- Bleeker W K, van der Plas J, Feitsma R I J, Agterberg J, Rigter G, de Vriesvan Rossen A, Pauwels E K J, Bakker J C. In vivo distribution and elimination of hemoglobin modified by intramolecular cross-linking with 2-nor-2-formylpyridoxal 5′-phosphate. J Lab Clin Med 1989; 113: 151–161
- Harper H A, Rodwell V W, Mayer P A. Review of physiological chemistry17th edition. Lange Medical Publications, Los Altos 1979
- Rothschild M A, Bauman A, Yalow R S, Berson S A. Tissue distribution of I131 labeled human serum albumin following intravenous administration. J Clin Invest 1955; 34: 1354–1358
- Feola M, Gonzalez H, Canizaro P C, Bingham D, Periman P. Development of a bovine stroma-free hemoglobin solution as a blood substitute. Surg Gynec Obstet 1983; 157: 399–408
- Marks D H, Brown D R. Antibody response to transfusion with pyridoxalated polymerized hemoglobin solution. Milit Med 1987; 152: 473–477