References
- Fan, X. D.; Yun, S. H. The Potential of Optofluidic Biolasers. Nat. Methods 2014, 11, 141–147. DOI: https://doi.org/10.1038/NMETH.2805.
- Dervisevic, E.; Voelcker, N. H.; Risbridger, G. K.; Tuck, L.; Cadarso, V. J. High-Aspect-Ratio SU-8-Based Optofluidic Device for Ammonia Detection in Cell Culture Media. ACS Sens. 2020, 5, 2523–2539. DOI: https://doi.org/10.1021/acssensors.0c00821.
- Gupta, R.; Labella, E.; Goddard, N. J. An Optofluidic Young Interferometer Sensor for Real-Time Imaging of Refractive Index in μTAS Applications. Sensor. Actuat. B Chem. 2020, 321, 128491. DOI: https://doi.org/10.1016/j.snb.2020.128491.
- Li, L.; Tang, D. W.; Song, Y. C.; Jiang, B. Dual-Film Optofluidic Microreactor with Enhanced Light-Harvesting for Photocatalytic Applications. Chem. Eng. J. 2018, 339, 71–77. DOI: https://doi.org/10.1016/j.cej.2018.01.074.
- Liu, J.; Xu, W.; Zhu, A.; Kang, H.; Cao, Y.; Long, F. Reusable Optofluidic Point-of-Care Testing Platform with Lyophilized Specific Antibody for Fluorescence Detection of Cholylglycine in Serum. Mikrochim. Acta 2020, 187, 439. DOI: https://doi.org/10.1007/s00604-020-04424-2.
- Sarkar, A.; Shivakiran Bhaktha, B. N.; Khastgir, S. P. Optofluidic Two-Dimensional Grating Volume Refractive Index Sensor. Appl. Opt. 2016, 55, 7247–7251. DOI: https://doi.org/10.1364/AO.55.007247.
- Zhu, X.; Zhan, Z.; Li, J.; Li, M.; Song, Y. High-Sensitivity Temperature Sensor Based on Fano Resonance in an Optofluidic Microcapillary Resonator. Appl. Opt. 2020, 59, 1259–1262. DOI: https://doi.org/10.1364/AO.383288.
- Chen, R.; Li, L.; Zhu, X.; Wang, H.; Liao, Q.; Zhang, M. Highly-Durable Optofluidic Microreactor for Photocatalytic Water Splitting. Energy 2015, 83, 797–804. DOI: https://doi.org/10.1016/j.energy.2015.02.097.
- Marazuela, D.; Moreno-Bondi, M. C. Fiber-Optic Biosensors—An Overview. Anal. Bioanal. Chem. 2002, 372, 664–682. DOI: https://doi.org/10.1007/s00216-002-1235-9.
- Ateya, D. A.; Erickson, J. S.; Howell, P. B.; Hilliard, L. R.; Golden, J. P.; Ligler, F. S. The Good, the Bad, and the Tiny: A Review of Microflow Cytometry. Anal. Bioanal. Chem. 2008, 391, 1485–1498. DOI: https://doi.org/10.1007/s00216-007-1827-5.
- Argyros, A. Microstructured Polymer Optical Fibers. J. Lightwave Technol. 2009, 27, 1571–1579. DOI: https://doi.org/10.1109/JLT.2009.2020609.
- Cao, K.; Liu, Y.; Han, Z.; Xu, Q.; Zhao, Y.; Lang, C. Photocontrol of a Microbubble in a Fiber-Based Hollow Microstructure. Opt. Express 2020, 28, 15090–15100. DOI: https://doi.org/10.1364/OE.390732.
- Arrospide, E.; Bikandi, I.; Larranaga, I.; Cearsolo, X.; Zubia, J.; Durana, G. Harnessing Deep-Hole Drilling to Fabricate Air-Structured Polymer Optical Fibres. Polymers-Basel 2019, 11, 1739. DOI: https://doi.org/10.3390/polym11111739.
- Woyessa, G.; Pedersen, J. K. M.; Nielsen, K.; Bang, O. Enhanced Pressure and Thermal Sensitivity of Polymer Optical Fiber Bragg Grating Sensors. Opt. Laser Technol. 2020, 130, 106357. DOI: https://doi.org/10.1016/j.optlastec.2020.106357.
- Chen, C. Y.; Guo, C. C.; Wang, L.; Jiang, W. Rapid Determination of Minocycline in Pharmaceutical Formulations and Human Urine/Serum Samples Based on the Minocycline-Europium-Sodium Dodecylbenzene Sulfonate Luminescence System. Anal. Lett. 2009, 42, 228–242. DOI: https://doi.org/10.1080/00032710802585741.
- Dutta, K.; Kumawat, K. L.; Nazmi, A.; Mishra, M. K.; Basu, A. Minocycline Differentially Modulates Viral Infection and Persistence in an Experimental Model of Japanese Encephalitis. J. Neuroimmune Pharmacol. 2010, 5, 553–565. DOI: https://doi.org/10.1007/s11481-010-9233-8.
- Wu, D.; Jackson-Lewis, V.; Vila, M.; Tieu, K.; Teismann, P.; Vadseth, C.; Choi, D.; Ischiropoulos, H.; Przedborski, S. Blockade of Microglial Activation is Neuroprotective in the 1-Methyl-4-Phenyl-1,2,3,6-Tetrahydropyridine Mouse Model of Parkinson Disease. J. Neurosci. 2002, 22, 1763–1771. DOI: https://doi.org/10.1523/JNEUROSCI.22-05-01763.2002.
- Tikka, T.; Fiebich, B. L.; Goldsteins, G.; Keinanen, R.; Koistinaho, J. Minocycline, a Tetracycline Derivative, Is Neuroprotective against Excitotoxicity by Inhibiting Activation and Proliferation of Microglia. J. Neurosci. 2001, 21, 2580–2588. DOI: https://doi.org/10.1523/JNEUROSCI.21-08-02580.2001.
- Lin, L.; Wang, X.; Wang, W.; Zhou, X.; Hargreaves, J. R. Cleaning up China's Medical Cabinet-An Antibiotic Take-Back Programme to Reduce Household Antibiotic Storage for Unsupervised Use in Rural China: A Mixed-Methods Feasibility Study. Antibiotics-Basel 2020, 9, 212. DOI: https://doi.org/10.3390/antibiotics.
- Wencewicz, T. A. Crossroads of Antibiotic Resistance and Biosynthesis. J. Mol. Biol. 2019, 431, 3370–3399. DOI: https://doi.org/10.1016/j.jmb.2019.06.033.
- Watkins, R. R.; Bonomo, R. A. Overview: Global and Local Impact of Antibiotic Resistance. Infect. Dis. Clin. North Am. 2016, 30, 313–322. DOI: https://doi.org/10.1016/j.idc.2016.02.001.
- Meseguer-Lloret, S.; Torres-Cartas, S.; Catala-Icardo, M.; Gomez-Benito, C. Selective and Sensitive Chemiluminescence Determination of MCPB: Flow Injection and Liquid Chromatography. Appl. Spectrosc. 2016, 70, 312–321. DOI: https://doi.org/10.1177/0003702815620133.
- Chen, X. Y.; Liu, C.; Xu, Z.; Pan, Y. Z.; Liu, J. S.; Du, L. Q. An Effective PDMS Microfluidic Chip for Chemiluminescence Detection of Cobalt (II) in Water. Microsyst. Technol. 2013, 19, 99–103. DOI: https://doi.org/10.1007/s00542-012-1551-8.
- Chen, X. Y.; Zeng, H.; Wei, X.; Yang, J. C. Chemiluminescence Detection for Cu (II) Based on 1,10-Phenanthroline-Hydrogen Peroxide Reaction on a PDMS Microfluidic Chip. Microsyst. Technol. 2014, 20, 209–213. DOI: https://doi.org/10.1007/s00542-013-1779-y.
- Chu, W.; Chen, Y.; Liu, W.; Zhao, M.; Li, H. Paper-Based Chemiluminescence Immunodevice with Temporal Controls of Reagent Transport Technique. Sensor. Actuat. B Chem. 2017, 250, 324–332. DOI: https://doi.org/10.1016/j.snb.2017.04.126.
- Amjadi, M.; Abolghasemi-Fakhri, Z. Gold Nanostar-Enhanced Chemiluminescence Probe for Highly Sensitive Detection of Cu(II) Ions. Sensor. Actuat. B Chem. 2018, 257, 629–634. DOI: https://doi.org/10.1016/j.snb.2017.11.013.
- Sun, Y.; Han, R.; Dai, Y.; Zhu, X.; Liu, H.; Gao, D.; Luo, C.; Wang, X.; Wei, Q. Highly Selective and Sensitive Streptomycin Chemiluminescence Sensor Based on Aptamer and G-Quadruplex DNAzyme Modified Three-Dimensional Graphene Composite. Sensor. Actuat. B Chem. 2019, 301, 127122. DOI: https://doi.org/10.1016/j.snb.
- Guo, C.; Zeng, H.; Ding, X.; He, D.; Li, J.; Yang, R.; Qu, L. Enhanced Chemiluminescence of the Luminol-K3Fe(CN)6 System by ZnSe Quantum Dots and Its Application. J. Lumin. 2013, 134, 888–892. DOI: https://doi.org/10.1016/j.jlumin.2012.06.022.
- Yue, L.; Liu, Y. Mechanistic Insight into pH-Dependent Luminol Chemiluminescence in Aqueous Solution. J. Phys. Chem. B. 2020, 124, 7682–7693. DOI: https://doi.org/10.1021/acs.jpcb.0c06301.
- Kładna, A.; Michalska, T.; Berczyński, P.; Kruk, I.; Aboul-Enein, H. Y. Evaluation of the Antioxidant Activity of Tetracycline Antibiotics in Vitro. Luminescence 2012, 27, 249–255. DOI: https://doi.org/10.1002/bio.1339.
- Orti, V.; Audran, M.; Gibert, P.; Bougard, G.; Bressolle, F. High-Performance Liquid Chromatographic Assay for Minocycline in Human Plasma and Parotid Saliva. J. Chromatogr. B 2000, 738, 357–365. DOI: https://doi.org/10.1016/S0378-4347(99)00547-2.
- Kong, B. Y.; Cao, Y. J.; Yu, Y. L.; Zhao, S. Synthesis of Sodium Thiosulfate-Reduced Copper Nanoclusters Using Bovine Serum Albumin as a Template and Their Applications in the Fluorometric Detection of Minocycline. Microchem. J. 2020, 159, 105388. DOI: https://doi.org/10.1016/j.microc.2020.105388.
- Souza, M. R. S.; Aragao, D. M.; Santos, R. H. T.; Garcia, C. A. B.; Alves, J. P. H.; Arguelho, M. Electrochemical Behavior of the Antibiotic Minocycline and Its Voltammetric Determination in Pharmaceutical Formulations at Carbon Paste Electrode. ECS Trans. 2012, 43, 289–296. DOI: https://doi.org/10.1149/1.4704969.
- Mascher, H. J. Determination of Minocycline in Human Plasma by High-Performance Liquid Chromatography with UV Detection after Liquid-Liquid Extraction. J. Chromatogr. A 1998, 812, 339–342. DOI: https://doi.org/10.1016/S0021-9673(98)00402-6.