276
Views
28
CrossRef citations to date
0
Altmetric
Original Articles

Transient Characteristics of Split Air-Conditioning Systems Using R-22 and R-410A as Refrigerants

, &
Pages 617-649 | Received 06 Oct 2007, Accepted 14 Jul 2008, Published online: 22 Feb 2011

REFERENCES

  • ARI . 2006 . ARI 210–240-2006: Performance rating of unitary air-conditioning and air-source heat pump equipment. Arlington, VA : Air-Conditioning, Heating, and Refrigeration Institute. .
  • Bansal , P. K. and Rupasinghe , A. S. 1998 . An homogeneous model for adiabatic capillary tubes . Applied Thermal Engineering , 18 ( 3–4 ) : 207 – 19 .
  • Bendapudi , S. and Braun , J. E. 2002 . A review of literature on dynamic models of vapour compression equipment. Atlanta : American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. . Report 4036–5
  • Browne , M. W. and Bansal , P. K. 2002 . Transient simulation of vapour-compression packaged liquid chillers . Int. J. Refrig. , 25 ( 5 ) : 597 – 610 .
  • Calm , J. M. and Domanski , P. K. 2004 . R-22 replacement status . ASHRAE Journal , 46 ( 8 ) : 29 – 39 .
  • Cavallini , A. , Del Col , D. , Doretti , L. , Longo , G. A. and Rossetto , L. 2000 . Heat transfer and pressure drop during condensation of refrigerants inside horizontal enhanced tube . Int. J. Refrig. , 23 ( 1 ) : 4 – 25 .
  • Chi , J. and Didion , D. 1982 . A simulation model of the transient performance of a heat pump . Int. J. Refrig. , 5 ( 3 ) : 176 – 84 .
  • Churchill , S. W. 1977 . Frictional equation spans all fluid flow regimes . Chemical Engineering , 84 ( 24 ) : 91 – 92 .
  • Devotta , S. , Waghmare , A. V. , Sawant , N. N. and Domkundwar , B. M. 2001 . Alternatives to HCFC-22 for air-conditioners . Applied Thermal Engineering , 21 ( 6 ) : 703 – 15 .
  • Dhar , M. and Soedel , W. Transient analysis of a vapor compression refrigeration system . Proceedings of 25th International Congress of Refrigeration . Venice, Ital. pp. 1031 – 67 .
  • Ding , G. 2007 . Recent development in simulation techniques for vapour-compression refrigeration systems . Int J Refrig. , 30 ( 7 ) : 1119 – 33 .
  • Domanski , P. A. and Didion , D. A. 1993 . Thermodynamic evaluation of alternative refrigerants and refrigerant mixtures . ASHRAE Transactions , 99 ( 2 ) : 636 – 48 .
  • F-Chart Software . 2004 . Engineering Equation Solver Madison, WI : F-Chart Software. .
  • Fu , L. , Ding , G. and Zhang , C. 2003 . Dynamic simulation of air-to-water dual-mode heat pump with screw compressor . Applied Thermal Engineering , 23 : 1629 – 45 .
  • Gado, Amr El-Sayed Alaa El-Din . 2006 . Development of a dynamic test facility for environmental control systems , PhD dissertation College Park, MD : University of Maryland. .
  • Goto , M. , Inoue , N. and Ishiwatari , N. 2001 . Condensation and evaporation heat transfer of R410A inside internally grooved horizontal tubes . Int J Refrig. , 24 : 628 – 38 .
  • Grald , E. W. and MacArthur , J. W. 1992 . A moving-boundary formulation for modeling time-dependent two-phase flow . Int J Heat and Fluid Flow , 13 ( 3 ) : 266 – 72 .
  • Haberschill , P. , Gay , L. , Auboin , P. and Lallemand , M. 2003 . Dynamic model of a vapor-compression refrigerating machine using R-407C . HVAC&R Research , 9 ( 4 ) : 451 – 66 .
  • Jabardo , J. M. S. , Bandarra Filho , E. P. and Barbieri , P. E. L. 2004 . Convective boiling pressure drop of refrigerant R-134a in horizontal smooth and microfin tubes . Int. J. Refrig. , 27 ( 8 ) : 895 – 903 .
  • Janssen , M. J. P. , De Wit , J. A. and Kuijpers , L. J. M. 1992 . Cyclic losses in domestic appliances: an experimental and theoretical analysis . Int J Refrig. , 15 ( 3 ) : 152 – 58 .
  • Jia , X. , Tso , C. P. , Jolly , P. G. and Chia , P. K. 1995 . A distributed model for prediction of the transient response of an evaporator . Int. J. Refrig. , 18 ( 5 ) : 336 – 42 .
  • Jia , X. , Tso , C. P. , Jolly , P. G. and Wong , Y. W. 1996 . Distributed study of air temperature inside a dry-expansion evaporator . Applied Thermal Engineering , 16 ( 4 ) : 305 – 11 .
  • Jia , X. , Tso , C. P. , Jolly , P. G. and Wong , Y. W. 1999 . Distributed steady and dynamic modelling of dry-expansion evaporators . Int. J. Refrig. , 22 ( 2 ) : 126 – 36 .
  • Judge , J. F. and Radermacher , R. 1997 . A heat exchanger model for mixture and pure refrigerant cycle simulation . Int. J. Refrig. , 20 ( 4 ) : 244 – 55 .
  • Judge , J. F. , Hwang , Yunho and Radermacher , R. 1996 . A transient and steady state study of pure and mixed refrigerants in a residential heat pump Washington, DC : U. S. Environmental Protection Agency. . Final Report, EPA Cooperative Agreement CR 822356, prepared for
  • Kim , M-H. and Bullard , C. W. 2001 . Dynamic characteristics of a R-410A split air-conditioning system . Int. J. Refrig. , 24 ( 7 ) : 652 – 59 .
  • Kim , Y. , Yun , R. , Seo , K. and Kim , H. Y. 2002 . A generalized correlation for evaporation heat transfer of refrigerants in micro-fin tubes . Int. J. Heat and Mass Transfer , 45 ( 10 ) : 2003 – 10 .
  • Koury , R. N. N. , Machado , L. and Ismail , K. A. R. 2001 . Numerical simulation of a variable speed refrigeration system . Int. J. Refrig. , 24 ( 2 ) : 192 – 200 .
  • Koyama , S. , Lee , J. and Yonemoto , R. 2004 . An investigation on void fraction of vapor–liquid two-phase flow for smooth and microfin tubes with R134a at adiabatic condition . Int. J. Multiphase Flow , 30 ( 3 ) : 291 – 310 .
  • Lin , S. , Kwok , C. C. K. , Li , R. Y. , Chen , Z. H. and Chen , Z. Y. 1991 . Local frictional pressure drop during vaporization of R-12 through capillary tubes . Int. J. Multiphase Flow , 17 ( 1 ) : 95 – 102 .
  • MacArthur , J. W. 1984a . Analytical representation of the transient energy interactions in vapour compression heat pumps . ASHRAE Transactions , 90 ( 1 ) : 982 – 96 .
  • MacArthur , J. W. 1984b . Theoretical analysis of the dynamic interactions of vapour compression heat pumps . Energy Conservation and Management , 24 ( 1 ) : 49 – 66 .
  • MacArthur , J. W. 1984c . Transient heat pump behaviour: a theoretical investigation . Int. J. Refrig. , 7 ( 2 ) : 123 – 32 .
  • MacArthur , J. W. and Grald , E. W. 1989 . Unsteady compressible two-phase flow model for predicting cyclic heat pump performance and a comparison with experimental data . Int. J. Refrig. , 12 ( 1 ) : 29 – 41 .
  • Mathworks . 2004 . MATLAB Version 7.0, (R14) Natick, MA : The Mathworks Inc. .
  • Mulroy , W. and Didion , D. 1983 . Refrigerant migration in a split unit air conditioner . ASHRAE Transactions , 91 ( 1A ) : 193 – 206 .
  • Murphy , W. and Goldschmidt , V. 1979 . The degradation coefficient of a field tested self-contained 3-ton air-conditioner . ASHRAE Transactions , 85 ( 2 ) : 396 – 405 .
  • Murphy , W. and Goldschmidt , V. 1984 . Transient response of air-conditioners—a qualitative interpretation through a sample case . ASHRAE Transactions , 90 ( 1B ) : 997 – 1008 .
  • Murphy , W. and Goldschmidt , V. 1985 . Cyclic characteristics of a typical residential air-conditioner – modeling of start-up transients . ASHRAE Transactions , 91 ( 2A ) : 427 – 44 .
  • Murphy , W. and Goldschmidt , V. 1986 . Cyclic characteristics of a residential air-conditioner—modeling of shut-down transients . ASHRAE Transactions , 92 ( 1A ) : 186 – 202 .
  • NIST . 2002 . REFPROP—Thermodynamic and transport properties of refrigerants and refrigerant mixtures, Standard Reference Database 23—Version 7.0 Gaithersburg, MD : National Institute of Standards and Technology. .
  • Nyers , J. and Stoyan , G. 1994 . A dynamical model adequate for controlling the evaporator of a heat pump . Int. J. Refrig. , 17 ( 2 ) : 101 – 108 .
  • Sami , S. M. and Comeau , M. A. 1991 . Experimental study of the dynamic behaviour of non-azeotropic binary mixtures in heat pumps . Heat Recovery Systems & CHP , 11 ( 6 ) : 505 – 15 .
  • Sami , S. M. and Dahmani , A. 1996 . Numerical prediction of dynamic performance of vapour compression heat pump using new HFC alternatives to HCFC-22 . Applied Thermal Engineering , 16 ( 8/9 ) : 691 – 705 .
  • Sami , S. M. and Tribes , C. 1998 . Numerical prediction of capillary tube behaviour with pure and binary alternative refrigerants . Applied Thermal Engineering. , 18 ( 6 ) : 491 – 502 .
  • Sami , S. M. , Duong , T. , Mercadier , Y. and Galanis , N. 1987 . Prediction of the transient response of heat pumps . ASHRAE Transactions , 93 ( 2 ) : 471 – 90 .
  • Tanaka , N. , Ikeuchi , M. and Yamanaka , G. 1982 . Experimental study on the dynamic characteristics of a heat pump . ASHRAE Transactions , 88 ( 2 ) : 323 – 31 .
  • Turaga , M. , Lin , S. and Fazio , P. P. 1988 . Correlation for heat transfer and pressure drop factors for direct expansion air cooling and dehumidifying coils . ASHRAE Transactions , 94 ( 2 ) : 616 – 29 .
  • Votsis , P. P. , Tassou , S. A. , Wilson , D. R. and Marquand , C. J. 1992 . Dynamic characteristics of an air-to-water heat-pump system . Int. J. Refrig. , 15 ( 2 ) : 89 – 94 .
  • Wang , H. and Touber , S. 1991 . Distributed and non-steady-state modelling of an air-cooler . Int. J. Refrig. , 12 : 98 – 111 .
  • Wang , J. and Wu , Y. 1990 . Start-up and shut-down operation in a reciprocating compressor refrigeration system with capillary tubes . Int. J. Refrig. , 13 ( 3 ) : 187 – 90 .
  • Wang , C. C. , Chiou , C. B. and Lu , D. C. 1996 . Single-phase heat transfer and flow friction correlations for microfin tubes . Int. J. Heat and Fluid Flow , 17 ( 5 ) : 500 – 506 .
  • Welsby , P. , Pezzane , M. , Devotta , S. , Diggory , P. J. and Guy , J. J. 1988 . Steady- and dynamic-state simulations of heat-pumps. Part II: Modelling of a motor driven water-to-water heat-pump . Applied Energy , 31 : 239 – 62 .
  • Williatzen , M. , Petit , N. B. O. L. and Ploug-Sorensen , L. 1998a . A general dynamic simulation model for evaporators and condenser in refrigeration: Part I—moving boundary formulation of two-phase flows with heat exchange . Int. J. Refrig. , 21 ( 5 ) : 398 – 403 .
  • Williatzen , M. , Petit , N. B. O. L. and Ploug-Sorensen , L. 1998b . A general dynamic simulation model for evaporators and condenser in refrigeration: Part II—simulation and control of an evaporator . Int. J. Refrig. , 21 ( 5 ) : 404 – 14 .
  • WINDIG . 1996 . Data Digitzer Version 2.5 Washington State Department of Natural Resources. .
  • Wongwises , S. and Pirompak , W. 2001 . Flow characteristics of pure refrigerants and refrigerant mixtures in adiabatic capillary tube . Applied Thermal Engineering. , 21 : 845 – 61 .
  • Yashar , D. A. , Wilson , M. J. , Kopke , H. R. , Graham , D. M. , Chato , J. C. and Newell , T. A. 2001 . An investigation of refrigerant void fraction in horizontal, micro-fin tubes . HVAC&R Research , 107 ( 2 ) : 173 – 88 .

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.