References
- Reubsaet , J. L.E. and Vieskar , R. 1999 . Characterisation of π‐π interactions which determine retention of aromatic compounds in reversed‐phase liquid chromatography . J. Chromatogr. A. , 841 ( 2 ) : 147 – 154 .
- Marchand , D. H. , Croes , K. , Dolan , J. W. , Snyder , L. R. , Henry , R. A. , Kallury , K. M.R. , Waite , S. and Carr , P. W. 2005 . Column selectivity in reversed‐phase liquid chromatography VIII. Phenylalkyl and fluoro‐substituted columns . J. Chromatogr. A. , 1062 ( 1 ) : 65 – 78 .
- Horak , J. , Maier , N. M. and Lindner , W. J. 2004 . Investigations on the chromatographic behavior of hybrid reversed‐phase materials containing electron donor–acceptor systems II. Contribution of π‐π aromatic interactions . J. Chromatogr. A. , 1045 ( 1–2 ) : 43 – 58 .
- Tanaka , N. , Tokuda , Y. , Iwaguchi , K. and Araki , M. 1982 . Effect of stationary phase structure on retention and selectivity in reversed‐phase liquid chromatography . J. Chromatogr. , 239 : 761 – 772 .
- Kibbey , C. E. and Meyerhoff , M. E. 1993 . Shape‐selective separation of polycyclic aromatic hydrocarbons by reversed‐phase liquid chromatography on tetraphenylporphyrin‐based stationary phases . J. Chromatogr. , 641 ( 1 ) : 49 – 55 .
- Kayillo , S. , Dennis , G. R. and Shalliker , R. A. 2006 . An assessment of the retention behaviour of polycyclic aromatic hydrocarbons on reversed phase stationary phases: Selectivity and retention on C18 and phenyl‐type surfaces . J. Chromatogr. A. , 1126 ( 1–2 ) : 283 – 297 .
- Sander , L. C. , Parris , R. M. , Wise , S. A. and Garrigues , P. 1991 . Shape discrimination in liquid chromatography using charge‐transfer phases . Anal. Chem. , 63 ( 22 ) : 2589 – 2597 .
- Turowski , M. , Morimoto , T. , Kimata , K. , Monde , H. , Ikegami , T. , Hosoya , K. and Tanaka , N. 2001 . Selectivity of stationary phases in reversed‐phase liquid chromatography based on the dispersion interactions . J. Chromatogr. A. , 911 ( 2 ) : 177 – 190 .
- Wilson , N. S. , Gilroy , J. , Dolan , J. W. and Snyder , L. R. 2004 . Column selectivity in reversed‐phase liquid chromatography VI. Columns with embedded or end‐capping polar groups . J. Chromatogr. A. , 1026 ( 1–2 ) : 91 – 100 .
- Euerby , M. R. and Petersson , P. 2003 . Chromatographic classification and comparison of commercially available reversed‐phase liquid chromatographic columns using principal component analysis . J. Chromatogr. A. , 994 ( 1–2 ) : 13 – 36 .
- Turowski , M. , Morimoto , T. , Kimata , K. , Monde , H. , Ikegami , T. , Hosoya , K. and Tanaka , N. 2001 . Selectivity of stationary phases in reversed‐phase liquid chromatography based on the dispersion interactions . J. Chromatogr. A. , 911 ( 2 ) : 177 – 190 .
- Bell , D. S. and Jones , A. D. 2005 . Solute attributes and molecular interactions contributing to “U‐shape” retention on a fluorinated high‐performance liquid chromatography stationary phase . J. Chromatogr. A. , 1073 ( 1–2 ) : 99 – 109 .
- Murahashi , T. 2003 . Comprehensive two‐dimensional high‐performance liquid chromatography for the separation of polycyclic aromatic hydrocarbons . Analyst , 128 ( 6 ) : 611 – 615 .
- Kimata , K. , Hirose , T. , Moriuchi , K. , Hosoya , K. , Araki , T. and Tanaka , N. 1995 . High‐capacity stationary phases containing heavy atoms for HPLC separation of fullerenes . Anal. Chem. , 67 ( 15 ) : 2556 – 2561 .
- West , C. and Lesellier , E. 2006 . Characterisation of stationary phases in subcritical fluid chromatography with the solvation parameter model IV Aromatic stationary phases . J. Chromatogr. A. , 1115 ( 1–2 ) : 233 – 245 .
- Murahashi , T. 2003 . Determination of mutagenic 3‐nitrobenzanthrone in diesel exhaust particulate matter by three‐dimensional high‐performance liquid chromatography . Analyst , 128 ( 1 ) : 42 – 45 .
- Murahashi , T. , Tsuruga , F. and Sasaki , S. 2003 . An automatic method for the determination of carcinogenic 1‐nitropyrene in extracts from automobile exhaust particulate matter . Analyst , 128 ( 11 ) : 1346 – 1351 .
- Murahashi , T. 2003 . Comprehensive two‐dimensional high‐performance liquid chromatography for the separation of polycyclic aromatic hydrocarbons . Analyst , 128 ( 6 ) : 611 – 615 .
- Kanai , M. , Porfyrakis , K. , Briggs , G. A.D. and Dennis , T. J.S. 2004 . Purification by HPLC and the UV/Vis absorption spectra of the nitrogen‐containing incar‐fullerenes iNC60, and iNC70 . Chem. Commun. , : 210 – 211 .
- Kayillo , S. 2005 . The Elucidation of Retention Behaviour and Molecular Interactions on Bonded‐Phases in High Performance Liquid Chromatographic Surfaces Australia : University of Western Sydney .
- Rimmer , C. A. , Simmons , C. R. and Dorsey , J. G. 2002 . The measurement and meaning of void volumes in reversed‐phase liquid chromatography . J. Chromatogr. A. , 965 ( 1–2 ) : 219 – 232 . PhD, Thesis
- Snyder , L. R. , Dolan , J. W. and Gant , J. R. 1979 . Gradient elution in high‐performance liquid chromatography I. Theoretical basis for reversed‐phase systems . J. Chromatogr. , 165 ( 1 ) : 3 – 30 .
- Zhao , J. and Carr , P. W. 1999 . Synthesis and evaluation of an aromatic polymer‐coated zirconia for reversed‐phase liquid chromatography . Anal. Chem. , 71 ( 22 ) : 5217 – 5224 .