References
- Alaska department of environmental conservation air quality regulations, section 18 AAC 50.077 2020. Accessed August 27, 2020. https://dec.alaska.gov/air/burnwise/standards/
- Allen, G. 1998. Invited comments on: Real-Time liquid water mass measurement for airborne particulates. Aerosol Science and Technology 29 (6):563–65. doi:10.1080/02786829808965591.
- Allen, G., L. Rector, T. Butcher, and R. Trojanowski. 2017. Evaluation of alternative filter media for particulate matter emission testing of residential wood heating devices. Journal of the Air & Waste Management Association 67 (10):1055–60. doi:10.1080/10962247.2017.1349011.
- Allen, G., C. Sioutas, P. Koutrakis, R. Reiss, F. W. Lurmann, and P. T. Roberts. 1997. Evaluation of the TEOM method for measurement of ambient particulate mass in urban areas. Journal of the Air & Waste Management Association 47 (6):682–89. doi:10.1080/10473289.1997.10463923.
- ASTM. 2011a. Method E2515-11, standard test method for determination of particulate matter emissions collected by a dilution tunnel. ASTM, West Conshohocken, PA. Accessed June 1, 2020. https://www.astm.org/Standards/E2515.htm
- ASTM. 2011b. Method ASTM D6831-11, standard test method for sampling and determining particulate matter in stack gases using an in-stack, inertial microbalance. ASTM, West Conshohocken, PA. Accessed June 1, 2020 https://www.astm.org/Standards/D6831.htm
- Burgher, E., M. Meyer, and G. Bailey. 2001. Validation of a new method for in-stack measurement of particulate matter emissions from large stationary sources. Presented at: Electric Utilities Environmental Conference on “Air Quality & Global Climate Change, Tucson, AZ January 8-12, 2001. Accessed June 24, 2021. https://www.envirotech-online.com/white-paper/air-monitoring/6/cem/validation-of-a-new-method-for-in-stack-measurement-ofnbspparticulate-matter-emissions-from-large-stationary-sources/74
- Carrico, C. M., S. L. Gomez, M. K. Dubey, and A. C. Aiken. 2018. Low hygroscopicity of ambient fresh carbonaceous aerosols from pyrotechnics smoke. Atmospheric Environment 178:101–08. doi:10.1016/j.atmosenv.2018.01.024.
- Chandrasekaran, S. R., J. R. Laing, T. M. Holsen, S. Raja, and P. K. Hopke. 2011. Emission characterization and efficiency measurements of high-efficiency wood boilers. Energy & Fuels 25 (11):5015–21. doi:10.1021/ef2012563.
- Corbin, J. C., A. Keller, U. Lohmann, H. Burtscher, B. Sierau, and A. A. Mensah. 2015. Organic emissions from a wood stove and a pellet stove before and after simulated atmospheric aging. Aerosol Science and Technology 49 (11):1037–50. doi:10.1080/02786826.2015.1079586.
- Goohs, K. 2014. Thermo Scientific PM CEMS: A dual-sensing technology. White Paper. Accessed June 1, 2020. https://assets.thermofisher.com/TFS-Assets/LSG/Vector-Information/EPM-PMCEMS-white-paper.pdf
- Grover, B. D., N. L. Eatough, D. J. Eatough, J. C. Chow, J. G. Watson, J. L. Ambs, M. B. Meyer, P. K. Hopke, R. Al-Horr, D. W. Later, et al. 2006. Measurement of both nonvolatile and semi-volatile fractions of fine particulate matter in Fresno, CA. Aerosol Science and Technology 40 (10):811–26. doi:10.1080/02786820600615071.
- Grover, B. D., M. Kleinman, N. L. Eatough, D. J. Eatough, P. K. Hopke, R. W. Long, W. E. Wilson, M. B. Meyer, and J. L. Ambs. 2005. Measurement of total PM2. 5 mass (nonvolatile plus semivolatile) with the Filter Dynamic Measurement System tapered element oscillating microbalance monitor. Journal of Geophysical Research: Atmospheres 110 (D7). doi:10.1029/2004JD004995.
- Hearth, Patio and Barbecue Association (HPBA). May 2, 2014 Comments of the hearth, patio & barbecue association on EPA’s proposed standards of performance for new residential wood heaters, new residential hydronic heaters and forced-air furnaces, and new residential masonry heaters. Accessed October 17, 2020. https://www.hpba.org/Portals/26/Documents/Government%20Affairs/NSPS%20Members/HPBA%202014%20NSPS/HPBACommentsMay22014.pdf
- Hearthlab Solutions. 2017. Wood species testing using crib and cordwood in a pre-NSPS residential wood heater. EPA-HQ-OAR-2016-0130-0010. Accessed June 1, 2020. https://www.nescaum.org/documents/epa-hq-oar-2016-0130-0010-1.pdf/
- Hiss, J., and H. Patashnick. 2000. Patent for “In-stack direct particulate mass measurement apparatus and method with pressure/flow compensation.” Accessed July 21, 2020. https://pdfpiw.uspto.gov/.piw?PageNum=0&docid=06016688
- Holder, A., T. Yelverton, A. Brashear, and P. Kariher. 2019. Black carbon emissions from residential wood combustion appliances. Report # EPA/600/R-20/039. Accessed August 9, 2020. https://cfpub.epa.gov/si/si_public_record_Report.cfm?Lab=CEMM&dirEntryId=348245
- Jaques, P. A., J. L. Ambs, W. L. Grant, and C. Sioutas. 2004. Field evaluation of the differential TEOM monitor for continuous PM2. 5 mass concentrations. Aerosol Science and Technology 38 (S1):49–59. doi:10.1080/02786820390229435.
- Kinsey, J. S., P. H. Kariher, and Y. Dong. 2009. Evaluation of methods for the physical characterization of the fine particle emissions from two residential wood combustion appliances. Atmospheric Environment 43 (32):4959–67. doi:10.1016/j.atmosenv.2009.07.008.
- Kinsey, J. S., A. Touati, T. L. Yelverton, J. Aurell, S. H. Cho, W. P. Linak, and B. K. Gullett. 2012. Emissions characterization of residential wood-fired hydronic heater technologies. Atmospheric Environment 63:239–49. doi:10.1016/j.atmosenv.2012.08.064.
- Kortelainen, M., J. Jokiniemi, P. Tiitta, J. Tissari, H. Lamberg, J. Leskinen, J. G. L. Rodriguez, H. Koponen, S. Antikainen, I. Nuutinen, et al. 2018. Time-resolved chemical composition of small-scale batch combustion emissions from various wood species. Fuel 233 (6):224–36. doi:10.1016/j.fuel.2018.06.056.
- Li, Q. F., L. Wang-Li, Z. Liu, and A. J. Heber. 2012. Field evaluation of particulate matter measurements using tapered element oscillating microbalance in a layer house. Journal of the Air & Waste Management Association 62 (3):322–35. doi:10.1080/10473289.2011.650316.
- Liu, C. N., S. F. Lin, A. Awasthi, C. J. Tsai, Y. C. Wu, and C. F. Chen. 2014. Sampling and conditioning artifacts of PM2.5 in filter-based samplers. Atmospheric Environment 85:48–53. doi:10.1016/j.atmosenv.2013.11.075.
- Marin, A., L. Rector, B. Morin, and G. Allen. 2022. Residential wood heating: An overview of U.S. impacts and regulations. Journal of the Air & Waste Management Association this issue.
- Meyer, M. B., H. Patashnick, J. Ambs, and E. Rupprecht. 2000. Development of a sample equilibration system for the TEOM continuous PM monitor. Journal of the Air & Waste Management Association 50 (8):1345–49. doi:10.1080/10473289.2000.10464180.
- Michell instruments humidity calculator, based on British Standards Institution BS 1339-1:2002. Accessed August 4, 2020. http://www.michell.com/us/calculator/
- Morin, B., M. Ahmadi, L. Rector, and G. Allen. 2022. Development of an integrated duty cycle test method to assess cordwood stove performance. Journal of the Air & Waste Management Association this issue.
- Naeher, L. P., M. Brauer, M. Lipsett, J. T. Zelikoff, C. D. Simpson, J. Q. Koenig, and K. R. Smith. 2007. Woodsmoke health effects: A review. Inhal. Toxicol 19 (1):67–106. doi:10.1080/08958370600985875.
- NESCAUM. 2008. Contribution of wood smoke to particle matter levels in connecticut: Source characterization of outdoor wood furnaces. Accessed July 21, 2020. http://www.nescaum.org/documents/source-characterization-of-outdoor-wood-furnaces
- NESCAUM. 2019. Measurement of black carbon in a wood stove method 5g dilution tunnel. Accessed December 30, 2021. http://www.nescaum.org/documents/measurement-of-black-carbon-28feb19-final.pdf/
- NESCAUM. 2020a. Standard operation procedures for thermo 1405 TEOM for use in a dilution tunnel or with an extractive dilution system. Accessed July 28, 2020. http://www.nescaum.org/topics/test-methods
- NESCAUM. 2020b. Interim report: Development of integrated duty-cycle test method for cordwood stoves. Accessed April 1, 2021. https://www.nyserda.ny.gov/About/Publications/Research-and-Development-Technical-Reports/-/media/925394CA61C54492B91930A3B5881377.ashx
- NESCAUM. 2021a. NYSERDA integrated duty cycle test method for certification of wood-fired stoves using cordwood: Measurement of Particulate Matter (PM) and Carbon Monoxide (CO) emissions and heating efficiency. Accessed June 3, 2021. https://www.nescaum.org/documents/nyserda-idc-protocols-for-epa-wood-stove-test-method-research/
- NESCAUM. 2021b. NYSERDA standard operation procedures for thermo scientific 1405-D TEOM for use in a dilution tunnel. Accessed June 3, 2021. https://www.nescaum.org/documents/nyserda-idc-protocols-for-epa-wood-stove-test-method-research/
- Patashnick, H., and G. Rupprecht. 1977. Development of a microbalance suitable for space application. NASA Report # NASA-CR-150334. Accessed July 28, 2020.https://ntrs.nasa.gov/search.jsp?R=19770020232
- Patashnick, H., and E. Rupprecht. 1991. Continuous PM-10 measurements using the tapered element oscillating microbalance. Journal of the Air & Waste Management Association 41 (8):1079–83. doi:10.1080/10473289.1991.10466903.
- Rousta, F., G. Ahmadi, and G. Allen. 2022. Computational modeling of woodstove pollutants in dilution tunnels. Journal of the Air & Waste Management Association this issue.
- Rupprecht, E., M. Meyer, and H. Patashnick. 1992. The tapered element oscillating microbalance as a tool for measuring ambient particulate concentrations in real time. Journal of Aerosol Science 23:635–38. doi:10.1016/0021-8502(92)90492-E.
- Shingler, T., A. Sorooshian, A. Ortega, E. Crosbie, A. Wonaschütz, A. E. Perring, A. Beyersdorf, L. Ziemba, J. L. Jimenez, P. Campuzano-Jost, et al. 2016. Ambient observations of hygroscopic growth factor and f(RH) below 1: Case studies from surface and airborne measurements. Journal of Geophysical Research: Atmospheres 121 (22):13–661.
- Sigsgaard, T., B. Forsberg, I. Annesi-Maesano, A. Blomberg, A. Bølling, C. Boman, J. Bønløkke, M. Brauer, N. Bruce, M. E. Héroux, et al. 2015. Health impacts of anthropogenic biomass burning in the developed world. European Respiratory Journal 46 (6):1577–88. doi:10.1183/13993003.01865-2014.
- Sullivan, B., G. Allawatt, A. Emery, P. Means, J. Kramlich, and J. Posner. 2017. Time-resolved particulate emissions monitoring of cookstove biomass combustion using a tapered element oscillating microbalance. Combustion Science and Technology 189 (6):923–36. doi:10.1080/00102202.2016.1253564.
- Swanson, J., and D. Kittelson. 2009. Factors influencing mass collected during 2007 diesel PM filter sampling. SAE International Journal of Fuels and Lubricants 2 (1):718–29. doi:10.4271/2009-01-1517.
- Thermo scientific series 1105/6100 diesel PM monitor brochure. 2005. Accessed July 21, 2020. https://www.thermo.com.cn/Resources/200802/productPDF_27325.pdf
- Trojanowski, R., T. A. Butcher, G. Wei, and Y. Celebi. 2019. Performance of a biomass boiler in a load profile test. BNL Report # BNL-211372-2019-INRE. Accessed August 5, 2020. https://www.osti.gov/biblio/1501610-performance-biomass-boiler-load-profile-test
- U.S. Environmental Protection Agency. 2010. Summary of public comments and responses for: Methods for measurement of filterable PM10 and PM2.5 and measurement of condensable particulate matter emissions from stationary sources. Docket ID: EPA-HQ-OAR-2008-0348. Accessed April 1, 2021. https://www3.epa.gov/ttnemc01/methods/comments201a202.pdf
- U.S. Environmental Protection Agency. 2015. Standards of performance for new residential wood heaters. 40 CFR Part 60.534(d), 80 FR 13702.March 16, 2015
- U.S. Environmental Protection Agency. 2016. Process for developing improved cordwood test methods for wood heaters discussion paper. Accessed October 15, 2020. https://www.epa.gov/sites/production/files/2016-03/documents/discussion_paper_-_process_for_dev_imp_cwtm_030916.pdf
- U.S. Environmental Protection Agency. 2017. Method 5G, Determination of Particulate Matter Emissions from Wood Heaters. Accessed December 2, 2020. https://www.epa.gov/emc/method-5G3-particulate-matter-wood-heaters-dilution-tunnel
- U.S. Environmental Protection Agency. 2018. 2014 national emissions inventory. Accessed November 6, 2019. https://gispub.epa.gov/neireport/2014/
- U.S. Environmental Protection Agency. 2019. Method 5I, determination of low level particulate matter emissions from stationary sources. Accessed July 21, 2020. https://www.epa.gov/emc/method-5i-determination-low-level-particulate-matter-emissions
- Wallace, L. A., W. R. Ott, K. C. Cheng, T. Zhao, and L. Hildemann. 2021. Method for estimating the volatility of aerosols using the piezobalance: Examples from vaping e-cigarette and marijuana liquids. Atmospheric Environment 253:118379. doi:10.1016/j.atmosenv.2021.118379.
- Weichenthal, S., R. Kulka, E. Lavigne, D. Van Rijswijk, M. Brauer, P. J. Villeneuve, … R. T. Burnett. 2017. Biomass burning as a source of ambient fine particulate air pollution and acute myocardial infarction. Epidemiology 28 (3):329. doi:10.1097/EDE.0000000000000636.