References
- Leal Ghezzi T, Campos Corleta O. Campos Corleta O. 30 years of robotic surgery. World J Surg. 2016;40(10):2550–2557.
- Szold A, Bergamaschi R, Broeders I, et al. European Association of Endoscopic Surgeons (EAES) consensus statement on the use of robotics in general surgery. Surg Endosc. 2015;29(2):253–288.
- Moorthy K, Munz Y, Dosis A, et al. Dexterity enhancement with robotic surgery. Surg Endosc. 2004;18(5):790–795.
- Okamura AM. Methods for haptic feedback in teleoperated robot-assisted surgery. Ind Rob. 2004;31(6):499–508.
- Ruurda J, Broeders I, Pulles B, et al. Manual robot assisted endoscopic suturing: time-action analysis in an experimental model. Surg Endosc. 2004;18(8):1249–1252.
- Van der Voort M, Heijnsdijk E, Gouma D. Bowel injury as a complication of laparoscopy. Br J Surg. 2004;91(10):1253–1258.
- Atsuta K, Ozawa S, Shimojima N, et al. Newly developed haptic forceps enables sensitive, real-time measurements of organ elasticity. Minim Invasive Ther Allied Technol. 2010;19(3):177–183.
- Heijnsdijk EA, Pasdeloup A, Dankelman J, et al. The optimal mechanical efficiency of laparoscopic forceps. Surg Endosc. 2004;18(12):1766–1770.
- Visser H, Heijnsdijk E, Herder J, et al. Forces and displacements in colon surgery. Surg Endosc. 2002;16(10):1426–11430.
- Oguma J, Ozawa S, Morikawa Y, et al. Knot-tying force during suturing and wound healing in the gastrointestinal tract. J Surg Res. 2007;140(1):129–134.
- Matsunaga T, Ohnishi K, Wada T, et al. [Development of small-diameter haptic flexible gripping forceps robot]. Denki Gakkai Ronbunshi D. IEEJ Trans IA. 2019;139(12):966–972. Japanese
- Tadano K, Kawashima K. Development of a master slave system with force sensing using pneumatic servo system for laparoscopic surgery. Proceedings 2007 IEEE International Conference on Robotics and Automation. Apr 10–14; Roma, Italy; 2007. p. 947–952.
- Tadano K, Kawashima K. Development of 4-DOFs forceps with force sensing using pneumatic servo system. Proc. IEEE Int. Conf. Robot. Autom. 2006;2250–2256. doi: https://doi.org/10.1109/ROBOT.2006.1642038.
- Okuda Y, Nakai A, Sato T, et al. New device with force sensors for laparoscopic liver resection – investigation of grip force and histological damage. Minim Invasive Ther Allied Technol. 2020;1–6. doi: https://doi.org/10.1080/13645706.2020.1755313.
- Hagelsteen K, Johansson R, Ekelund M, et al. Performance and perception of haptic feedback in a laparoscopic 3D virtual reality simulator. Minim Invasive Ther Allied Technol. 2019;28(5):309–316.
- Yokoyama M, Mizoguchi T, Matsunaga T, et al. Development of master-slave integrated haptic forceps based on bilateral control. 2017 IEEE International Conference on Advanced Intelligent Mechatronics. July 3–7; Munich, Germany; 2017. p. 743–748.
- Cartmill J, Shakeshaft A, Walsh W, et al. High pressures are generated at the tip of laparoscopic graspers. Aust N Z J Surg. 1999;69(2):127–130.
- Marucci DD, Cartmill JA, Walsh WR, et al. Patterns of failure at the instrument–tissue interface. J Surg Res. 2000;93(1):16–20.
- Yoshii I. [Morphological study on the muscular construction of intestine]. Jap J Smooth Musecle. 1967;2:120–128. Japanese
- Penninck DG, Nyland TG, Fisher PE, et al. Ultrasonography of the normal canine gastrointestinal tract. Vet Radiol Ultrasound. 1989;30(6):272–276.
- Fleischer AC, Muhletaler CA, James AE. Jr. Sonographic assessment of the bowel wall. AJR Am J Roentgenol. 1981;136(5):887–891.