- BLACKWELL, M., RAO, S., SIMON, D. and DIGIOIA, A., 1996, Design and evaluation of 3-D preoperative planning software: application to acetabular implant alignment. Carnagie Mellon University, The Robotics Institute, http://www.mrcas.ri.cmu.edu/papers.html.
- DIGIOIA, A. M., SIMON, D. A., JARAMAZ, B., BLACKWELL, M., MORGAN, F., O'TOOLE, R. V., COLGAN, B. and KISCHELL, E., HipNav: Pre-operative planning and intra-operative navigational guidance for acetabular implant placement in total hip replacement surgery. Medical Robotics and Computer Assisted Surgery, Technical Paper, http://mrcas.ri.cmu.edu/projects/hipnav/paper.html
- DIGIOIA, A. M., JARAMAZ, B., BLACKWELL, M., SIMON, D. A., MORGAN, F., MOODY, J. E., NIKOU, C., COLGAN, B. D., ASTON, C. A., LABARCA, R. S., KISCHELL, E. and KANADE, T., 1998, The Otto Aufranc Award. Image guided navigation system to measure intraoperativeIy acetabular implant alignment. Clinical Orthopaedics and Related Research, 355, 8-22.
- JARAMAZ, B., NIKOU, C., SIMON, D.A. and DIGIOIA, A. M., 1997, Range of motion after total hip arthroplasty: experimental verification of the analytical simulator. In First Joint CVRMed/ MRCAS Conference, (Grenoble: Springer Verlag), 573-582.
- O'TOOLE, R. V., JARAMAZ, B., DIGIOIA, A. M., 3rd, VISNIC, C. D. and REID, R. H., 1995, Biomechanics for preoperative planning and surgical simulations in orthopaedics. Computers in Biology and Medicine, 25, 183-191.
- SCHWARZENBACH, O., BERLEMANN, U., JOST, B., VISARIUS, H., ARM, E., LANGLOTZ, F., NOLTE, L.P. and OZDOBA, C., 1997, Accuracy of computer-assisted pedicle screw placement. An in vivo computed tomography analysis. Spine, 22, 452-458.
- SIMON, D. A., O'TOOLE, R. V., BLACKWELL, M., MORGAN, F., DIGIOIA, A. M. and KANADE, T., 1995, Accuracy validation in image-guided orthopaedic surgery. In Second International Symposium on Medical Robotics and Computer Assisted Surgery, Springer-Verlag, 185-192.
- SIMON, D. A., JARAMAZ, B., BLACKWELL, M., MORGAN, F., DIGIOIA, A. M., KISCHELL, E., COLGAN, B. and KANADE, T., 1997, Development and validation of a navigational guidance system for acetabular implant placement. In First Joint CVRMed/MRCAS Conference, (Grenoble: Springer-Verlag).
- BRANDT, G., ZIMOLONO, A., CARRAT, L., MERLOZ, P., STAUDTE, H. W., LAVALLEE, S., RADERMACHER, K. and RAU, G., 1999, CRIGOS: a compact robot for image-guided orthopedic surgery. IEEE Transactions on Information Technology in Biomedicine, 3, 252-260.
- BARGAR, W. L., BAUER, A. and BORNER, M., 1998, Primary and revision total hip replacement using the Robodoc system. Clinical Orthopaedics and Related Research, 354, 82-91.
- MITTELSTADT, B. D., KAZANZIDES, P., ZUHARS, J., WILLIAMSON, B., CAIN, P., SMITH, F. and BARGAR, W. L., The evolution of a surgical robot from prototype to human clinical use. Integrated Surgical Systems, Inc., http://www.cor.ssh.edu/projects/robodoc/technical.html. Technical Report, 1-6.
- TAYLOR, R. H., JOSKOWICZ, L., WILLIAMSON, B., GUEZIEC, A., KALVIN, A., KAZANZIDES, P., VAN VORHIS, R., YAO, J., KUMAR, R., BZOSTEK, A., SAHAY, A., BORNER, M. and LAHMER, A., 1999, Computer-integrated revision total hip replacement surgery: concept and preliminary results. Medical Image Analysis, 3, 301-319.
- SUGANO, N., OHZONO, K., NISHII, T., HARAGUCHI, K., SAKAI, T. and OCHI, T., 1998, Computedtomography-based computer preoperative planning for total hip arthroplasty. Computer Aided Surgery, 3, 320-324.
- SARTORIS, D. J., RESNICK, D., GERSHUNI, D., BIELECKI, D. and MEYERS, M., 1986, Computed tomography with multiplanar reformation and 3-dimensional image analysis in the preoperative evaluation of ischemie necrosis of the femoral head. Journal of Rheumatology, 13, 153-163.
- KORNER, C. E., MÁRTON, S., CRAVEY, C. C., BALZER, A., BALZER, W., TEMPEL, A., HEMPEL, J., MOLCH, M., GRAFE, M., DITTRICH, S., GARACK, R and SCHLEICHERDT, R., 1998, The ROBODOC, Martin-Ulbrich-Haus gGmbM, http://www.klinik-rothenburg.de/e -klinikframes/ e_dock.htm.
- JEROSCH, J., PEUKER, E., VON HASSELHACH, C., LAHMER, A., FILLER, T. and WITZEL, U., 1999, Computer assisted implantation of the femoral stem in THA -- an experimental study. International Orthopaedics, 23, 224-226.
- URS, Orthopedics ImpactCappa plamingstation URS Universal Robot Systems GmbH & Co. KG, http://www.medicalrobots.com/urs_en/start.html.
- HANDELS, H., EHRHARDT, J., PLOTZ, W. and POPPL, S. J., 2000, Virtual planning of hip operations and individual adaption of endoprostheses in orthopaedic surgery [In Process Citation]. International Journal of Medical Informatics 58-59, 21-28.
- HANDELS, H., 1999, Virtuelle Realität in der medizin. Institute for medical informatics, Medical University of Lübeck, http: //www.itm.mu-luebeck.de/Hochschultag1999/mul/staende/s20/ op.html.
- HANDELS, H., EHRHARDT, J., PETERS, P., PLOTZ, W. and POPPL, S. J., 1999, Computer-assisted planning of hip operations and design of endoprostheses using virtual three-dimensional models. In CARS. (Paris: Elsevier Science).
- HANDELS, H., EHRHARDT, J., PLOTZ, W. and POPPL, S. J., 1999, Computer-assisted planning and simulation of hip operations using virtual three-dimensional models. Studies in Health Technology and Informatics, 68, 686-689.
- SHAHIDI, R., TOMBROPOULOS, R and GRZESZCZUK, R., 1998, Clinical applications of threedimensional rendering of medical data sets. Proceedings of the IEEE, 86, 555-568.
- LORENSEN, W. E. and CLINE, H. E., 1987, Marching cubes: a high resolution 3D surface construction algorithm. Computer graphics, 21, 163-169.
- HEWITT, A., 1998, Research team shifts technology for 3-D visualization. Scientific computing & animation biocomputing & visualization, October, 14-16.
- HAUBNER, M., KRAPICHLER, C., LOSCH, A., ENGLMEIER, K. and VAN EIMEREN, W., 1987, Virtual reality in medicine-computer graphics and interaction techniques. IEEE transactions on information technology in biomedicine, 1, 61-72.
- ELVINS, T., 1992, A survey of algorithms for volume visualization. Computer graphics, 26, 194-201.
- BOISSONNAT, J. D., 1988, Shape reconstruction from planar cross sections. Computer vision, graphics, and image processing, 44, 1-29.
- WELCH, B. B., 1997, Practical programming in TcI and Tk 2nd edn. (Upper Saddle River, New Jersey: Prentice Hall).
- SCHROEDER, W., MARTIN, K. and LORENSEN, B., 1998, The visualisation toolkit 2nd edn. (Upper Saddle River, New Jersey: Prentice Hall).
- SCHROEDER, W., MARTIN, K., AVILA, L. S. and LAW, C., 2000, The visualization toolkit user's guide. (Clifton Park, New York: Kitware Inc.).
Effect of display modality on spatial accuracy of orthopaedic surgery pre-operative planning applications
Reprints and Corporate Permissions
Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?
To request a reprint or corporate permissions for this article, please click on the relevant link below:
Academic Permissions
Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?
Obtain permissions instantly via Rightslink by clicking on the button below:
If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.
Related research
People also read lists articles that other readers of this article have read.
Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.
Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.