598
Views
11
CrossRef citations to date
0
Altmetric
Original Articles

Accurate Transmission Line Fault Location Considering Shunt Capacitances Without Utilizing Line Parameters

&
Pages 1783-1794 | Received 21 Apr 2011, Accepted 16 Aug 2011, Published online: 31 Oct 2011

References

  • Eriksson , L. , Saha , M. M. and Rockefeller , G. D. 1985 . “An accurate fault locator with compensation for apparent reactance in the fault resistance resulting from remote-end infeed,” . IEEE Trans. Power Apparatus Syst. , Vol. PAS-104 ( 2 ) February : 424 – 436 .
  • Johns , A. T. , Moore , P. J. and Whittard , B. 1995 . “New technique for the accurate location of earth faults on transmission systems,” . IEE Proc. Generat. Transm. Distribut. , Vol. 142 ( 2 ) March : 119 – 127 .
  • Liao , Y. and Elangovan , S. 1998 . “Digital distance relaying algorithm for first-zone protection for parallel transmission lines,” . IEE Proc. Part C: Generat. Transm. Distribut. , Vol. 145 ( 5 ) September : 531 – 536 .
  • Girgis , A. A. , Hart , D. G. and Peterson , W. L. 1992 . “A new fault location technique for two-and three-terminal lines,” . IEEE Trans. Power Delivery , Vol. 7 ( 1 ) January : 98 – 107 .
  • Kezunovic , M. and Perunicic , B. 1996 . “Automated transmission line fault analysis using synchronized sampling at two ends,” . IEEE Trans. Power Syst. , Vol. 11 ( 1 ) February : 441 – 447 .
  • Jiale , S. , Guobing , S. , Qingqiang , X. and Qin , C. 2006 . “Time-domain fault location algorithm for parallel transmission lines using unsynchronized currents,” . Elect. Power Energy Syst. , Vol. 28 : 253 – 260 .
  • Liao , Y. and Kezunovic , M. 2007 . “Optimal estimate of transmission line fault location considering measurement errors,” . IEEE Trans. Power Delivery , Vol. 22 ( 3 ) July : 1335 – 1341 .
  • Kezunovic , M. and Liao , Y. “Fault location estimation based on matching the simulated and recorded waveforms using genetic algorithms,” . 7th International Conference on Developments in Power System Protection . 9–12 April . Amsterdam, , The Netherlands : RAI. .
  • Chen , C. S. , Liu , C. W. and Jiang , J. A. 2002 . “A new adaptive PMU based protection scheme for transposed/untransposed parallel transmission lines,” . IEEE Trans. Power Delivery , Vol. 17 ( 2 ) April : 395 – 404 .
  • Liao , Y. and Elangovan , S. 2006 . “Unsynchronized two-terminal transmission line fault location without using line parameters,” . IEE Proc. Part C: Generat. Transm. Distribut. , Vol. 153 ( 6 ) November : 639 – 643 .
  • Liao , Y. 2008 . “Transmission line fault location algorithms without requiring line parameters,” . Elect. Power Compon. Syst. , Vol. 36 : 1218 – 1225 .
  • The Mathworks, Inc. 2009 . MATLAB Help Manual Natick, MA : Author. . Chaps. 1 and 3

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.