References
- Zhou, M., Centeno, V., Thorp, J. S., and Phadke, A. G., “Calibrating instrument transformers with phasor measurements,” Electr. Power Comp. Syst., Vol. 40, No. 14, pp. 1605–1620, 2012.
- Korasli, C., “Three-phase current measurement using single toroidalcore current transformer”, Electr. Power Comp. Syst., Vol. 36, No. 3, pp. 213–223, 2008.
- Kucuksari, S., and Karady, G. G., “Experimental comparison of conventional and optical current transformers,” IEEE. Trans. Power Del., Vol. 25, No. 4, pp. 2455–2463, October 2010.
- Kucuksari, S., and Karady, G. G., “Complete model development for an optical current transformer,” IEEE Trans. Power Del., Vol. 27, No. 4, pp. 1755–1762, October 2012.
- Liang, C.-T., Chen, K.-L., Tsai, Y.-P., and Chen, N., “New electronic current transformer with a self-contained power supply,” IEEE Trans. Power Del., Vol. 30, No. 1, pp. 184–192, February 2015.
- IEC 60044-8. Instrument Transformers-Part 8: Electronic Current Transformers, 2002.
- IEC 61850-9-2. Communication Networks and Systems in Substations-Part 9-2: Sampled Values over ISO/IEC 8802-3, Ed.2, 2011.
- Faifer, M., Toscani, S., and Ottoboni, R., “Electronic combined transformer for power-quality measurements in high-voltage systems,” IEEE Trans. Instrum. Meas., Vol. 60, No. 6, pp. 2007–2013, June 2011.
- Yamada, T., Kon, S., Hashimoto, N., Yamaguchi, T., Yazawa, K., Kondo, R., and Kurosawa, K., “ECT evaluation by an error measurement system according to IEC 60044-8 and 61850-9-2,” IEEE Trans. Power Del., Vol. 27, No. 3, pp. 1377–1384, July 2012.
- Brandolini, A., Faifer, M., and Ottoboni, R., “A simple method for the calibration of traditional and electronic measurement current and voltage transformers,” IEEE Trans. Instrum. Meas., Vol. 58, No. 5, pp. 1345–1353, May 2009.
- Suomalainen, E.-P., and Hallstrom, J. K., “Onsite calibration of a current transformer using a Rogowski coil,” IEEE Trans. Instrum. Meas., Vol. 58, No. 4, pp. 1054–1058, April 2009.
- Djokic, B., “Calibration of Rogowski coils at power frequencies using digital sampling,” IEEE Trans. Instrum. Meas., Vol. 58, No. 4, pp. 751–755, April 2009.
- Draxler, K., Styblikova, R., Hlavacek, J., and Prochazka, R., “Calibration of Rogowski coils with an integrator at high currents,” IEEE Trans. Instrum. Meas, Vol. 60, No. 7, pp. 2434–2438, July 2011.
- Wang, P., and Tan, D., “A calibration method for power metering system with electronic instrument transformers”, in Proc. IEEE PES ISGT Europe, 2012, pp. 1–5.
- Wei, P., Cheng, C., Wang, X., Shan, X., and Sun, X., “A high-performance hybrid current transformer based on a fast variable optical attenuator,” IEEE Trans. Power Del., Vol. 29, No. 6, pp. 2656–2663, December 2014.
- Zhu, C., Huang, C., Zheng, J., and Yue, Y., “Real-time measurement of communication subsystem of intelligent electronic device,” in International Conference on Electric Information and Control, 2011, pp. 1–5.
- Huang, C., Zheng, J., Su, L., and Mei, J., “Configuration of electronic transformers,” Electr. Power Automat. Equipm., Vol. 30, No. 3, pp. 137–140, 2010.
- Yang, J., Zhou, Y., and Liu, K., “Research on phase compensation of electronic transformer,” Electr. Power Automat. Equipm., Vol. 27, No. 3, pp. 45–48, 2007.
- Zhu, C., Huang, C., Mei, J., and Zheng, J., “Design of smart merging unit based on FPGA and ARM,” Power Syst. Technol., Vol. 35, No. 6, pp 10–14, 2011.
- Huang, C., Zheng, J., and Mei, J., “FPGA-based logical control strategy of voltage parallel and voltage switch in digital substation,” Power Syst. Protect. Contr., Vol. 38, No. 22, pp. 196–199, 2010.
- Zhu, C., Mei, J., Huang, C., Ni, Y., and Zheng, J., “Delay compensation design for electronic measuring transformer,” Automat. Electr. Power Syst., Vol. 37, No. 21, pp. 184–189, November 2013.
- Meher, P. K., Valls, J., Juang, T.-B., Sridharan, K., and Maharatna, K., “50 years of CORDIC: algorithms, architectures, and applications,” IEEE Trans. Circuits Syst. I Reg. Papers, Vol. 56, No. 9, pp. 1893–1907, September 2009.
- Q/GDW 426-2010. The Technical Specification for Merging Unit in Smart Substation, 2010.
- Huang, C., Xiao, C., Fang, Y., and Zheng, J., “A method to deal with packet transfer delay of sampled value in smart substation,” Power Syst. Technol., Vol. 35, No. 1, pp. 5–10, 2011.
- Huang, C., Li, F., Ding, T., Jiang, Y., Guo, J., and Liu, Y., “A bounded model of the communication delay for system integrity protection systems,” IEEE Trans. Power Del., Vol. 31, No. 4, pp. 1921–1933, August 2016.
- Huang, C., Li, F., Zhou, D., Guo, J., Pan, Z., Liu, Y., and Liu, Y., “Data quality issues for synchrophasor applications Part I: A review,” J. Mod. Power Syst. Clean Energ., Vol. 4, No. 3, pp. 342–352, July 2016.
- Huang, C., Li, F., Zhan, L., Xu, Y., Hu, Q., Zhou, D., and Liu, Y., “Data quality issues for synchrophasor applications Part II: Problem formulation and potential solutions,” J. Mod. Power Syst. Clean Energ., Vol. 4, No. 3, pp. 353–361, July 2016.