References
- T. S. Kishore and S. K. Singal, “Optimal economic planning of power transmission lines: A review,” Renewable Sustainable Energy Rev., vol. 39, pp. 949–974, 2014. DOI:10.1016/j.rser.2014.07.125.
- H. Gunnaasankaraan, A. Viswanath, K. Mahata, and L. Goel, “Transmission planning by minimizing curtailment of market transactions,” Electr. Power Syst. Res., vol. 101, pp. 1–8, 2013. DOI:10.1016/j.epsr.2013.02.010.
- http://www.ons.org.br/ Access in: April 15th, 2015.
- P. F. Moreira and B. Millikan, O setor elétrico brasileiro e a sustentabilidade no século 21: Oportunidades e desafios, 2ed., Ed. International Rivers Network, November 2012. ( in Portuguese).
- M. S. Chen, Y. Ohba, L. Reynolds, and W. D. Dickson, “Losses in electrical power systems,” Electr. Power Syst. Res., vol. 1, pp. 9–19, 1977/78. DOI:10.1016/0378-7796(77)90004-9.
- EPE - EMPRESA DE PESQUISA ENERGÉTICA Ministério de Minas e Energia. Governo Federal. “Projeção da demanda de energia elétrica para os próximos 10 anos (2015–2024),” Rio de Janeiro, 2015. 78 p. <http://www.epe.gov.br/mercado/Documents/DEA03-2015-ProjeçõesdaDemandadeEnergiaElétrica 2015–2024.pdf>. Accessed: April 3rd , 2015. (in portuguese)
- FIRJAN. http://www.firjan.org.br/. Accessed: April 3rd, 2015.
- S. Mukoyama, et al., “Development of (RE)BCO cables for HTS power transmission lines,” Physica C, vol. 469, pp. 1688–1692, 2009. DOI:10.1016/j.physc.2009.05.251.
- M. Yagi, et al., “Design and evaluation of 275 kV-3 kA HTS power cable,” Phys. Procedia, vol. 45, pp. 277–280, 2013. DOI:10.1016/j.phpro.2013.05.021.
- J. R. Riba, “Analysis of formulas to calculate the AC resistance of different conductors' configurations,” Electr. Power Syst. Res., vol. 127, pp. 93–100, 2015. DOI:10.1016/j.epsr.2015.05.023.
- R. D. Castro, “Overview of the transmission line design process,” Electr. Power Syst. Res., vol. 35, pp. 109–118, 1995. DOI:10.1016/0378-7796(95)00996-5.
- B. Burks, D. L. Armentrout, and M. Kumosa “Failure prediction analysis of an ACCC conductor subjected to thermal and mechanical stresses,” IEEE Trans. Dielectrics Electrical Insulation, vol. 17, pp. 588–596, 2010. DOI:10.1109/TDEI.2010.5448116.
- C. R. F. Azevedo and T. Cescon “Failure analysis of aluminum cable steel reinforced (ACSR) conductor of the transmission line crossing the Parana´ River,” Eng. Fail. Anal., vol. 9, pp. 645–664, 2002. DOI:10.1016/S1350-6307(02)00021-3.
- C. R. F. Azevedo, A. M. D. Henriques, A. R. Pulino Filho, J. L. A. Ferreira, and J. A. Araújo, “Fretting fatigue in overhead conductors: Rig design and failure analysis of a Grosbeak aluminium cable steel reinforced conductor,” Eng. Fail. Anal., vol. 16, pp. 136–151, 2009. DOI:10.1016/j.engfailanal.2008.01.003.
- D. Bryant, “The world's most efficient high capacity transmission conductor,” [ Online] http://www.arb.co.za/pdf/distributors/ctc/ACCC-Presentation.pdf, Set. 2013.
- Fonte: http://www.conduspar.com.br/?q=pt-br/produto/cabo-aluminio-com-alma-em-composito-acccr-htls. Accessed in: June 24th, 2015.
- J. P. C. Magalhães, “Cabos de Alta Temperatura em Linhas Aereas AT Condições de Falha térmica/mecânica,” Master Dissertation, FEUP – Faculdade de Engenharia do Porto, 2013. ( in Portuguese)
- T. F. A. Santos, G. C. Vasconcelos, W. A. de Souza, M. L. Costa, and E. C. Botelho, “Suitability of carbon fiber-reinforced polymers as power cable cores: Galvanic corrosion and thermal stability evaluation,” Mater. Des., vol. 65, pp. 780–788, 2015. DOI:10.1016/j.matdes.2014.10.005.
- J. U. Yan-zhong, L. I. Qiu-chen, and M. E. N. G. Ya-nan, Comparative Research on Aluminum Conductor Composite Core and Traditional Conductor. East China Electric Power, 2011.
- F. Liu and R. D. Findaly, “Investigation of mechanical properties of single layer ACSR based on an Integrated Model,” Electr. Power Syst. Res., vol. 78, pp. 209–216, 2008. DOI:10.1016/j.epsr.2007.02.001.
- IEEE Guide to the Installation of Overhead Transmission Line Conductors, publication in 2004.03.30.
- J. C. Wan, et al., “Fiber Reinforced Polymer Cores on newly constructed line and reconstructed line,” Electricity Distribution (CICED), 2010 China International Conference – IEEE, 13–16 September 2010.
- J. Wen-dong and Z. Yong, Application of ACCC to Capacity-Increasing Projects for Lines. East China Electric Power, 2011.
- International Standard IEC 60826 – Design criteria of overhead transmission lines, third edition 2003–10. Available at https://webstore.iec.ch/preview/info_iec60826%7Bed3.0%7Den_d.pdf. Accessed in April 8, 2016.
- IEEE C2: National electrical Safety code, 1997, Institute of Electrical and Electronics Engineers.
- C. K. C. Arruda and A. C. Lima, “Corona modeling in HVDC transmission lines based on a modified particle-in-cell approach,” Electr. Power Syst. Res., vol. 125, pp. 91–99, 2015. DOI:10.1016/j.epsr.2015.03.028.
- F. W. PEEK, Dielectric Phenomena in High Voltage Engineering. Ed. McGraw Hill, 1915.
- ONS Operador Nacional do Sistema Elétrico, “Submódulo 2.4, Requisitos mínimos para linhas de transmissão aéreas,” Accessed in 1st July, 2015. ( in Portuguese)
- Transmission Line Reference Book, 345 kV and above, 2 edition, Palo Alto, CA: Electric Power Research Institute, 1982.
- A. Z. El Dein, “Parameters affecting the charge distribution along overhead transmission lines conductors and their resulting electric field,” Electr. Power Syst. Res., vol. 108, pp. 198–210, 2014. DOI:10.1016/j.epsr.2013.11.011.
- IEEE Standard for calculating the current–temperature of bare overhead conductors, IEEE Std 738 – 2006, January 2007.
- ASTM Standard test method for resistivity of electrical conductor materials, Standard B 193 – 02, July 2009.
- R. Benato, A. Paolucci, EHV AC Undergrounding Electrical Power, Ed. Springer, 2010, pp. 33.