340
Views
16
CrossRef citations to date
0
Altmetric
Original Articles

Evaluation of a Standardized Micro-Vacuum Sampling Method for Collection of Surface Dust

, , , &
Pages 215-223 | Published online: 31 Oct 2007

REFERENCES

  • Nygren , O. and Wahlberg , J. E. 1998 . Speciation of chromium in tanned leather gloves and relapse of chromium allergy from tanned leather samples . Analyst , 123 : 935 – 937 .
  • Tinkle , S. S. , Antonini , J. M. Rich , B. A. 2003 . Skin as a route of exposure and sensitization in chronic beryllium disease . Environ. Health Perspect , 111 : 1202 – 1208 .
  • Far , H. S. , Pin , N. T. and Hong , C. Y. 1993 . An evaluation of the significance of mouth and hand contamination for lead absorption in lead acid battery plant workers . Int. Arch. Occup. Environ. Health , 64 : 439 – 443 .
  • Lewis , R. D. , Sterling , D. A. King , B. 1999 . Evidence of large particle allergen inhalation from contact with surfaces . Ann. Allergy Asthma Immunol. , 83 : 41 – 48 .
  • Whelan , E. A. , Piacitelli , G. M. Gerwel , B. 1997 . Elevated blood lead levels in children of construction workers . Am. J. Publ. Health , 87 : 1352 – 1355 .
  • Lichtenwalner , C. P. 1992 . Evaluation of wipe sampling procedures and elemental surface contamination . Am. Ind. Hyg. Assoc. J. , 53 : 657 – 659 .
  • McArthur , B. 1992 . Dermal measurement and wipe sampling methods—A review . Appl. Occup. Environ. Hyg. , 7 : 599 – 606 .
  • Ashley , K. , Schlecht , P. C. Song , R. 1996 . “ ASTM sampling methods and analytical validation for lead in paint, dust, soil and air ” . In Sampling Environmental Media , Edited by: Morgan , J. H. 125 – 136 . West Conshohocken, Pa. : American Society for Testing and Materials (ASTM) . (ASTM Spec. Tech. Publ. No. 1282)
  • ASTM International: ASTM D6966 . 2003 . Standard Practice for Collection of Settled Dust Samples Using Wipe Sampling Methods for Subsequent Determination of Metals [Standard] , West Conshohocken, Pa. : ASTM International .
  • Byrne , M. A. 2000 . Suction methods for assessing contamination on surfaces . Ann. Occup. Hyg. , 44 : 523 – 528 .
  • Que Hee , S. S. , Peace , B. Clark , C. S. 1985 . Evolution of efficient methods to sample lead sources, such as house dust and hand dust, in the homes of children . Environ. Res. , 38 : 77 – 95 .
  • Creek , K. L. , Whitney , G. and Ashley , K. 2006 . Vacuum sampling techniques for industrial hygienists, with emphasis on beryllium dust sampling . J. Environ. Monit. , 8 : 612 – 618 .
  • ASTM International: ASTM D7144 . 2005 . Standard Practice for Collection of Surface Dust by Micro-Vacuum Sampling for Subsequent Metals Determination [Standard] , West Conshohocken, Pa. : ASTM International .
  • ASTM International: ASTM D5755 . 2003 . Standard Test Method for Micro-Vacuum Sampling and Indirect Analysis of Dust by Transmission Electron Microscopy for Asbestos Structure Number Surface Loading [Standard] , West Conshohocken, Pa. : ASTM International .
  • ASTM International: ASTM D5756 . 2002 . Standard Test Method for Micro-Vacuum Sampling and Indirect Analysis of Dust by Transmission Electron Microscopy for Asbestos Mass Concentration [Standard] , West Conshohocken, Pa. : ASTM International .
  • ASTM International: ASTM E1973 . 1999 . Standard Practice for Collection of Surface Dust by Micro-Vacuum Sampling for Subsequent Lead Determination [Standard] , West Conshohocken, Pa. : ASTM International . (withdrawn 2005)
  • ASTM International: ASTM D5438 . 2000 . Standard Practice for Collection of Floor Dust for Chemical Analysis [Standard] , West Conshohocken, Pa. : ASTM International .
  • Reynolds , S. J. , Etre , L. Thorne , P. S. 1997 . Laboratory comparison of vacuum, OSHA, and HUD sampling methods for lead in household dust . Am. Ind. Hyg. Assoc. J. , 58 : 439 – 446 .
  • Lanphear , B. P. , Emond , M. Jacobs , D. E. 1995 . A side-by-side comparison of dust collection methods for sampling lead-contaminated household dust . Environ. Res. , 68 : 114 – 123 .
  • Sterling , D. A. , Roegner , K. C. Lewis , R. D. 1999 . Evaluation of four sampling methods for determining exposure of children to lead-contaminated household dust . Environ. Res. , 81 : 130 – 141 .
  • National Institute for Occupational Safety and Health (NIOSH) . 1994 . NIOSH Manual of Analytical Methods (NMAM), , 4th Edition , Cincinnati, Ohio : NIOSH . Method No. 0500
  • Chen , C. C. and Baron , P. A. 1996 . Aspiration efficiency and inlet wall deposition in the fiber sampling cassette . Am. Ind. Hyg. Assoc. J. , 57 : 142 – 152 .
  • Smith , J. and Bartley , D. L. 2003 . Effect of sampler and manikin conductivity on the sampling efficiency of manikin-mounted personal samplers . Aerosol Sci. Technol. , 37 : 79 – 81 .
  • Wheeler , J. P. and Stancliffe , J. D. 1998 . Comparison of methods for monitoring solid particulate surface contamination in the workplace . Ann. Occup. Hyg. , 42 : 477 – 488 .
  • Lundgren , L. , Skare , L. and Liden , C. 2006 . Measuring dust on skin with a small vacuuming sampler—A comparison with other sampling techniques . Ann. Occup. Hyg. , 50 : 95 – 103 .

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below: