REFERENCES
- Greenburg , L. 1922 . A New Instrument for Sampling Aerial Dust , 2392 Washington , D.C. : United States Department of the Interior, Bureau of Mines . Report of Investigations
- Fieldner , A. C. 1921 . The Sugar-Tube Method of Determining Rock Dust in Air , 278 Washington , D.C. : U.S. Department of the Interior, Bureau of Mines . Technical paper
- Brown , C. E. 1944 . Filter-Paper Method for Obtaining Dust-Concentration Results Comparable to Impinger Results , 3788 Washington , D.C. : U.S. Department of the Interior, Bureau of Mines . Report of Investigations
- Paulus , H. J. , Talvitie , N. A. , Fraser , D. A. and Keenan , R. G. 1957 . Use of membrane filters in air sampling . Am. Ind. Hyg. Assoc. Q. , 18 : 267 – 273 .
- American Conference of Governmental Industrial Hygienists (ACGIH) . 1960 . Air Sampling Instruments, , 1st edition , B–2 – 14 . 15 Akron , Ohio : ACGIH .
- U.S. Federal Standard 209 . Cleanroom and Work Station Requirements, Controlled Environments Available from Institute of Environmental Sciences and Technology, 940 East Northwest Highway, Mount Prospect, IL 60056, 1963 and later
- International Organization for Standardization (ISO) . 1999–2006 . Cleanrooms and Associated Controlled Environments , Geneva : ISO . (ISO 14644, Parts 1–8). [Standard]
- Linch , A. L. and Corn , M. 1965 . The standard midget impinger—Design improvement and miniaturization . Am. Ind. Hyg. Assoc. J. , 26 : 601 – 610 .
- Bien , C. T. and Corn , M. 1971 . Adherence of inlet conditions for selected aerosol sampling instruments to suggested criteria . Am. Ind. Hyg. Assoc. J. , 32 : 453 – 456 .
- Davies , C. N. 1968 . The entry of aerosols into sampling tubes and heads . Br. J. Appl. Phys. Series 2 , 1 : 921 – 932 .
- Linch , A. L. , Wiest , E. G. and Carter , M. D. 1970 . Evaluation of tetraalkyl lead exposure by personnel monitor surveys . Am. Ind. Hyg. Assoc. J. , 31 : 170 – 179 .
- Breslin , J. A. and Stein , R. L. 1975 . Efficiency of dust sampling inlets in calm air . Am. Ind. Hyg. Assoc. J. , 36 : 576 – 583 .
- National Institute for Occupational Safety and Health (NIOSH) . 1977 . “ Method S349 ” . In NIOSH Manual of Analytical Methods (NMAM), , 2nd edition , Vol. 3 , Cincinnati , Ohio : NIOSH . Department of Health, Education, and Welfare, NIOSH Pub No. 77-157-C
- National Institute for Occupational Safety and Health (NIOSH) . 1977 . Documentation of the NIOSH Validation Tests, S262 and S349 , Cincinnati , Ohio : NIOSH . Department of Health, Education, and Welfare, NIOSH, Pub. No. 77–185
- Beaulieu , H. J. , Fidino , A. V. , Kim , L. B. , Arlington , M. S. and Buchan , R. M. 1980 . A comparison of aerosol sampling techniques. “Open” versus “closed-face” filter cassettes . Am. Ind. Hyg. Assoc. J. , 41 : 758 – 765 .
- Buchan , R. M. , Soderholm , S. C. and Tillery , M. I. 1986 . Aerosol sampling efficiency of 37-mm filter cassettes . Am. Ind. Hyg. Assoc. J. , 47 : 825 – 831 .
- International Organization for Standardization (ISO) . 1995 . Air Quality - Particle Size Fraction Definitions for Health-Related Sampling , Geneva : ISO . (ISO 7708) [Standard]
- Lidén , G. and Harper , M. 2006 . The need for an international sampling convention for inhalable dust in calm air . J. Occup. Environ. Hyg. , 3 : D94 – D101 .
- American Conference of Governmental Industrial Hygienists . 2006 . Threshold Limit Values and Biological Exposure Indices , 81 – 83 . Cincinnati , Ohio : ACGIH .
- Kenny , L. C. , Aitken , R. Chalmers , C. 1997 . A collaborative European study of personal inhalable aerosol sampler performance . Ann. Occup. Hyg. , 41 : 135 – 153 .
- Aitken , R. J. , Baldwin , P. E.J. , Beaumont , G. C. , Kenny , L. C. and Maynard , A. D. 1999 . Aerosol inhalability in low air movement environments . J. Aerosol Sci. , 30 : 613 – 626 .
- Kenny , L. C. , Aitken , R. J. , Baldwin , P. E.J. , Beaumont , G. and Maynard , A. D. 1999 . The sampling efficiency of personal inhalable aerosol samplers in low air movement environments . J. Aerosol Sci. , 30 : 627 – 638 .
- Werner , M. A. , Spear , T. M. and Vincent , J. H. 1996 . Investigation into the impact of introducing workplace aerosol standards based on the inhalable fraction . Analyst , 121 : 1207 – 1214 .
- Mark , D. and Vincent , J. H. 1986 . A new personal sampler for airborne total dust in workplaces . Ann. Occup. Hyg. , 30 : 89 – 102 .
- Mark , D. 1990 . The use of dust-collecting cassettes in dust sampling . Ann. Occup. Hyg. , 34 : 281 – 291 .
- Health and Safety Executive (HSE) . 1996 . Large Particle and Wall Deposition Effects in Inhalable Samplers , Edited by: Aitken , R. J. and Donaldson , R. Sudbury, Suffolk , , U.K : HSE . HSE Contract Research Report No. 117/1996
- Witschger , O. , Grinshpun , S. A. , Fauvel , S. and Basso , G. 2004 . Performance of personal inhalable aerosol samplers in very slowly moving air when facing the aerosol source . Ann. Occup. Hyg. , 4 : 351 – 368 .
- Lidén , G. , Melin , B. , Lidblom , A. , Lindberg , K. and Norén , J.-O. 2000 . Personal sampling in parallel with open-face filter cassettes and IOM samplers for inhalable dust. Implications for occupational exposure limits . Appl. Occup. Environ. Hyg. , 15 : 263 – 276 .
- Demange , M. , Görner , P. , Elcabache , J.-M. and Wrobel , R. 2002 . Field comparison of 37-mm closed-face cassettes and IOM samplers . Appl. Occup. Environ. Hyg. , 17 : 200 – 208 .
- Hetland , S. and Thomassen , Y. 1993 . Sampling efficiencies of the American 25 mm personal sampler . Poster presented at Airmon: Modern Principles of Workplace Air Monitoring . June 12–16 1993 , Geilo , Norway .
- Chen , C.-C. and Baron , P. A. 1996 . Aspiration efficiency and inlet wall deposition in the fiber sampling cassette . Am. Ind. Hyg. Assoc. J. , 57 : 142 – 152 .
- National Institute for Occupational Safety and Health (NIOSH) . 1994 . NIOSH Manual of Analytical Methods (NMAM), , 4th edition , Cincinnati , Ohio : NIOSH .
- Occupational Safety and Health Administration (OSHA) . 2003 . “ Method PV2121, Gravimetric Detemination ” . In OSHA Sampling and Analysis Methods , Salt Lake City , Utah : OSHA .
- Ashley , K. , Andrews , R. N. , Cavazos , L. and Demange , M. 2001 . Ultrasonic extraction as a sample preparation technique for elemental analysis by atomic spectrometry . J. Anal. At. Spectrom. , 16 : 1147 – 1153 .
- Stones , F. , Edwards , S. , Crane , D. and Schultz , G. 2004 . The deposition of sample analyte on cassette walls . Poster presentation, American Industrial Hygiene Conference & Exposition . May 8–13 2004 , Atlanta , Georgia .
- Fabriès , J. F. 1985 . Methodology for the analysis of particulate pollutants , Vandoeuvre , , France : INRS . (Internal report), [In French.]
- European Economic Community (EEC) . 1982 . European Economic Community Council Directive 82/605/EEC of 28 July 1982 on the protection of workers from the risks related to exposure to metallic lead and its ionic compounds at work . Official Journal of the European Community , : 12
- Association Francaise de Normalisation (AFNOR) . 1988 . Air Quality. Workplace Air—Sampling and Analysis of Lead-Containing Aerosols , Paris : AFNOR . (NF X 43-256) [Standard], [In French.]
- Demange , M. , Gendre , J. C. , Hervé-Bazin , B. , Carton , B. and Peltier , A. 1990 . Aerosol evaluation difficulties due to particle deposition on filter holder inner walls . Ann. Occup. Hyg. , 34 : 399 – 403 .
- Institut National de Recherche et Sécurité (INRS) . 2005 . MétroPol , France : INRS . Fiche No. 003: Métaux. Metalloïdes. Vandœuvre-les-Nancy
- Association Francaise de Normalisation (AFNOR) . 2002 . Air Quality - Workplace Air—Determination by Atomic Spectrometry of Elements Present in Workplace Air , Paris : AFNOR . (NF X 43-275) [Standard]
- Health & Safety Executive (HSE) . 1986–2007 . Methods for the Determination of Hazardous Substances (MDHS) Guidances , Series Sudbury, Suffolk , , U.K. : HSE .
- International Organization for Standardization . 2001 . Workplace Air. Determination of Metals and Metalloids in Airborne Particulate Matter by Inductively Coupled Plasma Atomic Emission Spectrometry. Part 2: Sample Preparation , Geneva : ISO . (ISO 15202-2) [Standard]
- Harper , M. , Pacolay , B. , Hintz , P. and Andrew , M. E. 2006 . A comparison of XRF and ICP-OES for lead on air filter samples from a lead ore concentrator mill and a lead-acid battery recycler . J. Environ. Monit. , 8 : 384 – 392 .
- Harper , M. 2006 . A review of workplace aerosol sampling procedures and their relevance to the assessment of beryllium exposures . J. Environ. Monit. , 8 : 598 – 604 .
- Demange , M. and Görner , P. “Comparative aerosol sampling data: 37-mm CFC and IOM cassettes.” . Poster presented at Airmon: Fifth International Symposium on Modern Principles of Air Monitoring . Loen , Norway .
- Puskar , M. A. , Harkins , J. M. , Mooney , J. D. and Heckler , L. H. 1991 . Internal wall losses of pharmaceutical ducts during closed-face, 37-mm polystyrene cassette sampling . Am. Ind. Hyg. Assoc. J. , 52 : 280 – 286 .
- Puskar , M. A. , Fergon , S. M. , Harkins , J. M. and Hecker , L. H. 1992 . Gravimetric determination of airborne dust by using a filter cartridge inside a closed-face, 37-mm polystyrene cassette . Am. Ind. Hyg. Assoc. J. , 53 : 692 – 698 .