Man-Made Vitreous Fibers in Office Buildings in the Helsinki Area

, , , , &
Pages 624-631 | Published online: 22 Jul 2010

REFERENCES

  • Carter , C. M. , Axten , C. W. Byers , C. D. 1999 . Indoor airborne fiber levels of MMVF in residential and commercial buildings . Am. Ind. Hyg. Assoc. J. , 60 : 794 – 800 .
  • “Official Statistics of Finland 2007 Building Stock Statistics, Housing” [Online] Available at http://tilastokeskus.fi/til/rak/index_en.html(Accessed September 2008)
  • Nomenclature Committee of TIMA . 1993 . Man-Made Vitreous Fibers: Nomenclature, Chemical and Physical Properties , Stamford, Conn : North American Insulation Manufactures Association .
  • Kojola , W. H. and Moran , J. B. 1992 . Exposure limits for man-made mineral fibers. Position of the building and construction trades department, AFL-CIO . Appl. Occup. Environ. Hyg. , 7 : 724 – 733 .
  • International Labor Office (ILO) . 2001 . ILO Codes of Practice. Safety in the Use of Synthetic Vitreous Fibre Insulation Wools (Glass Wool, Rock Wool, Slag Wool) , Geneva : ILO .
  • “Refractory ceramic fibers” [Online]. Available at http://www.epa.cov/iris/subst/0647.htm(Accessed March 2009)
  • Skaug , V. 1996 . The Nordic Expert Group for criteria documentation of health risks from chemicals. Refractory ceramic fibers . Arbete och hälsa , 121 : 1 – 40 .
  • Marchant , G. E. , Amen , M. A. Bullock , C. H. 2002 . A synthetic vitreous fiber (SVF) occupational exposure database: Implementing the SVF health and safety partnership program . Appl. Occup. Environ. Hyg. , 17 : 276 – 285 .
  • International Agency for Research on Cancer (IARC) . 2002 . Man-Made Vitreous Fibers Vol. 81 , Lyon, , France IARC Monographs on the Evaluation of Carcinogenic Risks to Humans
  • Rossiter , C. E. 2002 . “ Man-Made Vitreous Fibers ” . In Arbete och Hälsa (Work and Health) , Stockholm : National Institute for Working Life .
  • “Official Statistics of Finland 2007 Labour Force Statistics. Labour Market” [Online] Available at http://tilastokeskus.fi/til/tyti/index_en.html(Accessed September 2008)
  • Kovanen , K. , Riala , R. , Tuovila , H. and Tossavainen , A. Man made mineral fiber emission from HVAC-components . Proceedings of Ninth REHVA World Congress, Clima 2007 . Helsinki, Finland. Available at http://www.irbdirekt.de/daten/iconda/CIB7466.pdf(Accessed September 2008)Paper 1508 published on CD-ROM
  • Schneider , T. 2000 . “ Synthetic vitrous fibers ” . In Indoor Air Quality Handbooks , Edited by: Spengler , J. D. , Samet , J. M. and McCarthy , J. F. 39.1 – 39.29 . New York : McGraw-Hill .
  • Schneider , T. and Lundqvist , G. 1986 . Man-made mineral fibers in the indoor, non-industrial environment . Build. Environ. , 21 : 129 – 133 .
  • Vallarino , J. 2001 . “ Fibers ” . In Indoor Air Quality Handbook , Edited by: Spengler , J. D. , Samet , J. M. and McCarthy , J. F. 37.1 – 37.22 . New York : McGraw-Hill .
  • Vallarino , J. , Spengler , J. D. , Buck , R. and Dilwali , K. M. 2003 . Quantifying synthetic vitreous fiber surface contamination in office buildings . AIHA J. , 64 : 80 – 87 .
  • Hedge , A. , Erickson , W. A. and Rubin , G. Effects of man-made mineral fibers in settled dust on sick building syndrome in air-conditioned offices . Proceedings of the Sixth International Conference on Indoor Air Quality and Climate . Edited by: Saarela , K. , Kalliokoski , P. and Seppänen , O. Vol. 1 , pp. 291 – 296 . Helsinki : Helsinki University of Technology . Indoor Air 1993 July 4–8, 1993
  • Schneider , T. 1986 . Man-made mineral fibers and other fibers in the air and in settled dust . Environ. Int. , 12 : 61 – 65 .
  • Schneider , T. , Petersen , O. H. , Aasbjerg , Nielsen A. and Windfield , K. 1990 . A geostatistical approach to indoor surface sampling strategies . J. Aerosol. Sci. , 21 : 555 – 567 .
  • ASTM International . 1999 . Practice for Sampling for Particulate Contamination by Tape Lift , Philadelphia, Pa : ASTM . (E1216–99). [Standard]
  • Wheeler , J. P. and Stancliffe , J. D. 1998 . Comparison of methods for monitoring solid particulate surface contamination in the workplace . Ann. Occup. Hyg. , 42 ( 7 ) : 477 – 488 .
  • World Health Organization (WHO) . 1997 . Determination of Airborne Fibre Number Concentrations. A Recommended Method by Phase-Contrast Optical Microscopy (Membrane Filter Method) , Geneva : WHO .
  • World Health Organization (WHO) . 1991 . Indoor air quality: Inorganic fibers . Environ. Technol. , 12 : 833 – 835 .
  • Finnish Ministry of the Environment . 2003 . Suomen rakentamismääräyskokoelma, Rakennusten sisäilmasto ja ilmanvaihto, määräykset ja ohjeet, D2, (National Building Code of Finland, D2. Indoor Climate and Ventilation in Buildings, Regulations and Guidelines) , Helsinki : Finnish Ministry of the Environment . [In Finnish]
  • Paananen , H. , Holopainen , M. Kalliokoski , P. 2004 . Evaluation of exposure to man-made vitreous fibers by nasal lavage . J. Occup. Environ. Hyg. , 1 : 82 – 87 .
  • Agency for Toxic Substances and Disease Registry (ATSDR) . 2002 . Health Effects from Exposure to Fibrous Glass, Rock Wool or Slag Wool , Atlanta : ATSDR, U.S. Department of Health and Human Services . Technical Briefing Paper.
  • Schneider , T. , Nielsen , O. , Bredsdorff , P. and Linde , P. 1990 . Dust in buildings with man-made mineral ceiling boards . Scand. J. Work. Environ. Health. , 16 : 434 – 439 .
  • Abbritti , G. , Muzi , G. , Accattoli , M. P. Accattoli , M. P. 1992 . High prevalence of sick building syndrome in a new air-conditioned building in Italy . Arch. Environ. Health. , 47 ( 1 ) : 16 – 22 .
  • Franck , C. 1986 . Eye symptoms and signs in buildings with indoor climate problems . Acta Ophthal. , 64 : 306 – 311 .
  • Kreiss , K. and Hodgson , M. J. 1984 . “ Building-associated epidemics ” . In Indoor Air Quality , Edited by: Walsh , P. J. , Dudney , C. S. and Copenhaver , E. D. 87 – 106 . Boca Raton, Fla : CRC Press .
  • Lob , M. , Guillelmin , M. , Madelaine , P. and Boillat , A. 1984 . “ Collective dermatitis in a modern office ” . In Ergonomics and Health in Modern Offices , Edited by: Grandjean , E. 52 – 58 . London : Taylor & Francis Press .
  • Raw , G. J. , Roys , M. S. and Whitehead , C. 1993 . Sick building syndrome: Cleanliness is next to healthiness . Indoor Air , 3 : 237 – 245 .
  • Heisel , E. B. and Hunt , F. E. 1968 . Further studies in cutaneous reactions to glass fibers . Arch. Environ. Health. , 17 : 705 – 711 .
  • Possick , P. , Gellin , G. and Key , M. 1970 . Fibrous glass dermatitis . Am. Ind. Hygiene Assoc. J. , 31 : 12 – 15 .
  • Stam-Westerveld , E. B. , Coenraads , P. J. , van der Valk , P. G. , de Jong , M. C. and Fidler , V. 1994 . Rubbing test response of the skin to man-made vitreous fibers of different diameters . Contact Dermatitis , 31 : 1 – 4 .
  • Schneider , T. 2008 . Resolving indoor—Air problems . Scand. J. Work Environ. Health. Suppl. , 4 : 10 – 17 .
  • Schneider , T. 2008 . Dust and fibers as a cause of indoor environment problems . Scand. J. Work Environ. Health Suppl. , 4 : 25 – 29 .
  • Corrigan , C. A. and Blehm , K. E. 1997 . A comparison of tape sampling and microvacuum procedures for the collection of surface glass fiber contamination . Appl. Occup. Environ. Hyg. , 12 : 751 – 755 .
  • Farkas , J. 1983 . Fibreglass dermatitis in employees of a project-office in a new building . Contact Dermatitis , 9 : 79
  • Palomäki , E. , Uitti , J. , Virtema , P. , Voutilainen , R. , Heinijoki , L. and Savolainen , A. 2008 . Decreasing irritation symptoms by replacing partially coated acoustic glass wool boards with fully coated boards . Scand. J. Work Environ. Health Suppl. , 4 : 64 – 68 .
  • Verbeck , S. J.A. , Buise-van Unnik , E. M.M. and Malten , K. E. 1981 . Itching in office workers from glass fibers . Contact Dermatitis , 7 : 354

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.