Effect of Calibration and Environmental Condition on the Performance of Direct-Reading Organic Vapor Monitors

, , , &
Pages 670-680 | Published online: 27 Sep 2012

REFERENCES

  • National Institute for Occupational Safety and Health (NIOSH) . Manual of Analytical Methods: Glossary of Abbreviations, Definitions, and Symbols . [Online] Available at http://www.cdc.gov/niosh/docs/2003-154/pdfs/glossary.pdf (accessed October 19, 2011)
  • Coy , J. D. , Bigelow , P. L. , Buchan , R. M. , Tessari , J. D. and Parnell , J. O. 2000 . Field evaluation of a portable photoionization detector for assessing exposure to solvent mixtures . Am. Ind. Hyg. Assoc. J. , 61 : 268 – 274 .
  • Drummond , I. 1997 . On-the-fly calibration of direct reading photoionization detectors . Am. Ind. Hyg. Assoc. J. , 58 : 820 – 822 .
  • Poirot , P. , Subra , I. , Gerardin , F. , Baudin , V. , Grossmann , S. and Hery , M. 2004 . Determination of short-term exposure with a direct reading photoionization detector . Ann. Occup. Hyg. , 48 ( 1 ) : 75 – 84 .
  • Barsky , J. B. , Que Hee , S. S. and Clark , C. S. 1985 . An evaluation of the response of some portable, direct-reading 10.2 eV and 11.8 eV photoionization detectors, and a flame ionization gas chromatograph for organic vapors in high humidity atmospheres . Am. Ind. Hyg. Assoc. J. , 46 : 9 – 14 .
  • Lee , I. , Hee , S. and Clark , C. 1987 . Additivity of detector responses of a portable direct-reading 10.2 eV photoionization detector and a flame ionization gas-chromatograph for atmospheres of multicomponent organics—Use of PID/FID ratios . Am. Ind. Hyg. Assoc. J. , 48 : 437 – 441 .
  • Longworth , T. L. , Barnhouse , J. L. and Ong , K. Y. 2000 . Domestic Preparedness Program—Testing of MIRAN SapphIRe Portable Ambient Air Analyzers against Chemical Warfare Agents Summary Report. Aberdeen Proving Ground, Md.: Soldier and Biological Chemical Command, . Available at http://www.chem-bio.com/resource/2000/miran_sapphire_analyzers.pdf (accessed October 19, 2011)
  • Longworth , T. L. , Cajigas , J. C. , Barnhouse , J. L. , Ong , K. Y. and Procell , S. A. 1999 . Testing of Commercially Available Detectors Against Chemical Warfare Agents Summary Report. Aberdeen Proving Ground, Md., . Available at http://www.chem-bio.com/resource/1999/dp_detectors_summary.pdf (accessed October 19, 2011)
  • Coffey , C. , Pearce , T. , Lawrence , R. , Hudnall , J. , Slaven , J. and Martin , S. 2009 . Measurement capability of field portable organic vapor monitoring instruments under different experimental conditions . J. Occup. Environ. Hyg. , 6 : 1 – 8 .
  • Federal Emergency Management Administration (FEMA) . Responder Knowledge Database: Product Details—MIRAN SapphIRe Portable Gas Analyzer . Available at http://www.rkb.us/contentdetail.cfm?content_id=99649&query=&overridesubtype=630 (accessed Octo ber 19, 2011)
  • FEMA . Responder Knowledge Database: Product Details—TVA-1000B (FID or FID/PID) Toxic Vapor Analyzer . Available at http://www.rkb.us/contentdetail.cfm?content_id=68107&query=&overridesubtype=630 (accessed October 19, 2011)
  • Thermo Electron Corporation . 2004 . Miran 205B Series SapphIRe Portable Ambient Air Analyzers Instruction Manual (P/N BK3538) , Franklin , Mass : Thermo Electron Corporation .
  • National Institute for Occupational Safety and Health (NIOSH) . Pocket Guide to Chemical Hazards . Available at http://www.cdc.gov/niosh/npg/default.html (accessed October 19, 2011)
  • Thermo Electron Corporation . 2003 . TVA-1000B Toxic Vapor Analyzer Instruction Manual (P/N BK3500) , Franklin , Mass : Thermo Electron Corporation .
  • Scorecard Chemical Profiles . Available at http://www.scorecard.org/chemical-profiles/def/hpv.html (accessed on December 28, 2011)
  • National Institute for Occupational Safety and Health (NIOSH) . “Determination of CBRN Organic Vapor (Cyclohexane) Service-Life Test, CET-APRS-STP-CBRN-0301 . Available at http://www.cdc.gov/niosh/npptl/stps/pdfs/CET-APRS-STP-CBRN-0301.pdf (accessed on December 29, 2011)
  • Occupational Safety and Health Administration (OSHA) . Chemical Sampling Information, Cyclohexane . Available at http://www.osha.gov/dts/chemicalsampling/data/CH_230600.html (accessed October 19, 2011)
  • National Institute for Occupational Safety and Health (NIOSH) . Manual of Analytical Methods: Method 1500 . Available at http://www.cdc.gov/niosh/nmam/pdfs/1500.pdf (accessed October 19, 2011)
  • Thermo Electron Corporation . 2004 . TVA-1000 Series Response Factors Instruction Manual (P/N 50039) , Franklin , Mass : Thermo Electron, Corporation .
  • Middendorf , P. J. , Lehocky , A. H. and Williams , P. L. 1999 . Evaluation and field calibration of the Miniram PDM-3 aerosol monitor for measuring respirable and total coal dust . Am. Ind. Hyg. Assoc. J. , 60 : 502 – 511 .
  • Hervé , A. 2007 . “ The Bonferonni and Šidák Corrections for multiple comparisons ” . In Encyclopedia of Measurement and Statistics , Edited by: Salkind , N. Thousand Oaks , Calif : Sage Publishing, Inc. .
  • Valco Instruments Co., Inc. 2009 . M Series Pump Models M6 and M50 Instruction Manual , Houston , Texas : Valco .
  • Beghi , S. and Guillot , J.-M. 2006 . Sample water removal method in volatile organic compound analysis based on diffusion through poly(vinyl fluoride) film . J. Chromatogr. A , 1127 : 1 – 5 .
  • Ness , S. A. 1991 . Air Monitoring for Toxic Exposures: An Integrated Approach , New York , N.Y. : Van Nostrand Reinhold .
  • Todd , L. A. 2003 . “ Direct-reading instrumental methods for determining concentrations of gases, vapors, and aerosols ” . In The Occupational Environment: Its Evaluation, Control, and Management , Edited by: DiNardi , S. R. 280 – 302 . Fairfax , Va. : American Industrial Hygiene Association .
  • Haag , W. and Wrenn , C. 2002 . Theory and Applications of Direct-Reading Photoionization Detectors (PIDs) , Sunnyvale , Calif. : RAE Systems, Inc. .
  • Chelton , C. F. , Zakraysek , N. , Lautner , G. M. and Confer , R. G. 1983 . Evaluation of the performance and response of the Bacharach TLV sniffer and H-Nu photoionization gas analyzer to common hydrocarbon solvents . Am. Ind. Hyg. Assoc. J. , 44 : 710 – 715 .

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.