Investigation of particle transfer to sampler covers during the transportation of samples

, , , &

References

  • Ceballos D, King B, Beaucham C, Brueck S. 2015. Comparison of a wipe method with and without a rinse to recover wall losses in closed face 37-mm cassettes used for sampling lead dust particulates. J Occup Environ Hyg. 12(10):D225–D231. doi:10.1080/15459624.2015.1009991
  • Cena LG, Chen BT, Keane MJ. 2016. Evolution of welding-fume aerosols with time and distance from the source: a study was conducted on the spatiotemporal variability in welding-fume concentrations for the characterization of first- and second-hand exposure to welding fumes. Weld J. 95(Suppl):280s–285s.
  • Demange M, Gendre JC, Hervé-Bazin B, Carton B, Peltier A. 1990. Aerosol evaluation difficulties due to particle deposition on filter holder inner walls. Ann Occup Hyg. 34(4):399–403.
  • Harper M, Akbar MZ, Andrew ME. 2004. Comparison of wood-dust aerosol size-distributions collected by air samplers. J Environ Monit. 6:18–22. doi:10.1039/b312883k
  • Harper M, Demange M. 2007. Concerning sampler wall deposits in the chemical analysis of airborne metals. J Occup Environ Hyg. 4:D81–D86. doi:10.1080/15459620701493149
  • Harper M, Pacolay B. 2006. A comparison of X-ray fluorescence and wet chemical analysis for lead on air filters from different personal samplers used in a secondary lead smelter/solder manufacturer. J Environ Monitor. 8(1):140–146. doi:10.1039/b504719f
  • Harper M, Pacolay B, Andrew ME. 2005. A comparison of X-ray fluorescence and wet chemical analysis for lead on air filters from different personal samplers used in a bronze foundry. J Environ Monitor. 7:592–597. doi:10.1039/b502170g
  • Harper M, Pacolay B, Hintz P, Andrew ME. 2006. A comparison of XRF and ICP-OES for lead on air filter samples from a lead ore concentrator mill and a lead-acid battery recycler. J Environ Monitor. 8:384–392. doi:10.1039/b518075a
  • Hendricks W, Stones F, Lillquist D. 2009. On wiping the interior walls of 37-mm closed-face cassettes: an OSHA perspective. J Occup Environ Hyg. 6:732–734. doi:10.1080/15459620903012028
  • Hetland S, Thomassen Y. Sampling efficiencies of the American 25-mm personal sampler. Poster presented at Airmon: Modern Principles of Workplace Air Monitoring; 1993 Jun 12–16; Geilo, Norway.
  • Hinds WC. 1988. Basis for particle size-selective sampling for wood dust. Appl Ind Hyg. 3(3):67–72. doi:10.1080/08828032.1988.10389273
  • Hornung RW, Reed LD. 1990. Estimation of average concentration in the presence of nondetectable values. Appl Occup Environ Hyg. 5(1):46–51. doi:10.1080/1047322X.1990.10389587
  • Lee EG, Cena L, Kwon J, Afshari A, Park H, Casuccio G, Bunker K, Lersch T, Gall A, Pham H, et al. 2020. Characterization of aerosolized particles from nanoclay-enabled composites during manipulation processes. Environ Sci Nano. 7(5):1539–1553. doi:10.1039/C9EN01211G
  • Lee EG, Grimson P, Chisholm WP, Kashon ML, He X, L’Orange C, Volckens J. 2019. Performance evaluation of disposable inhalable aerosol sampler at a copper electrorefinery. J Occup Environ Hyg. 16(3):250–257. doi:10.1080/15459624.2019.1568444
  • NIOSH. 2020. Chapter AE: factors affecting aerosol sampling. In: Baron PA, editor. NIOSH manual of analytical methods. 5th ed. [accessed 2021 Mar 10]. https://www.cdc.gov/niosh/nmam/pdf/NMAM_5thEd_EBook-508-final.pdf.
  • NIOSH Method 0501. NIOSH manual of analytical methods (NMAM). 5th ed. [Issued 2015] Cincinnati (OH): Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health. [accessed 2021 Mar 10]. https://www.cdc.gov/niosh/docs/2014-151/pdfs/methods/0501.pdf.
  • NIOSH Method 7302. NIOSH manual of analytical methods (NMAM). 5th ed. [Issued 2014] Cincinnati (OH): Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health. [accessed 2021 Mar 10]. https://www.cdc.gov/niosh/docs/2014-151/pdfs/methods/7302.pdf.
  • NIOSH Method 7303. NIOSH manual of analytical methods (NMAM). 4th ed. [Issued 2003] Cincinnati (OH): Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health [accessed 2021 Mar 10]. https://www.cdc.gov/niosh/docs/2003-154/pdfs/0500.pdf.
  • OSHA. 2006. OSHA analytical methods manual. 2nd ed.; Method ID215 (version 2): Hexavalent chromium, rev. 2006. Salt Lake City (UT): U.S. Department of Labor; OSHA Salt Lake Technical Center.
  • OSHA. 2008. OSHA sampling and analytical methods. Methods ID-121, ID-125g, and ID-215. Sandy (UT): U.S. Department of Labor, Occupational Safety and Health Administration.
  • Pisaniello DL, Connell KE, Muriale L. 1991. Wood dust exposure during furniture manufacture - results from an Australian survey and considerations for threshold limit value development. Ann Ind Hyg Assoc J. 52(11):485–492. doi:10.1202/0002-8894(1991)052<0485:WDEDFM>2.0.CO;2
  • Puskar MA, Harkins JM, Moomey JD, Hecker LH. 1991. Internal wall losses of pharmaceutical dusts during closed-face, 37-mm polystyrene cassette sampling. Am Ind Hyg Assoc J. 52:280–286. doi:10.1080/15298669191364730
  • Whitehead LW, Freund T, Hahn LL. 1981. Suspended dust concentrations and size distributions, and qualitative analysis of inorganic particles, from woodworking operations. Am Ind Hyg Assoc J. 42(6):461–467. doi:10.1080/15298668191420062

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.