867
Views
0
CrossRef citations to date
0
Altmetric
Articles

Lissajous confocal fluorescent endomicroscopy with a lever mechanism and a frequency separation by an asymmetric polymer tube

ORCID Icon, ORCID Icon, ORCID Icon, ORCID Icon, ORCID Icon, & ORCID Icon show all

References

  • Hamashima, C.; Shabana, M.; Okada, K.; Okamoto, M.; Osaki, Y. Mortality Reduction from Gastric Cancer by Endoscopic and Radiographic Screening. Cancer Sci. 2015, 106, 1744–1749. DOI: 10.1111/cas.12829.
  • Pfau, P. R.; Sivak, M. V. Jr. Endoscopic Diagnostics. Gastroenterology 2001, 120, 763–781. DOI: 10.1053/gast.2001.22429.
  • Muto, M.; Minashi, K.; Yano, T.; Saito, Y.; Oda, I.; Nonaka, S.; Omori, T.; Sugiura, H.; Goda, K.; Kaise, M.; et al. Early Detection of Superficial Squamous Cell Carcinoma in the Head and Neck Region and Esophagus by Narrow Band Imaging: A Multicenter Randomized Controlled Trial. J. Clin. Oncol. 2010, 28, 1566–1572. DOI: 10.1200/JCO.2009.25.4680.
  • Song, C.; Kim, T. J.; Gweon, D. G. Beam Scanning Confocal Differential Heterodyne Interferometry. Int. J. Optomechatronics 2007, 1, 27–45. DOI: 10.1080/15599610701261076.
  • Schulz-Hildebrandt, H.; Pfeiffer, T.; Eixmann, T.; Lohmann, S.; Ahrens, M.; Rehra, J.; Draxinger, W.; König, P.; Huber, R.; Hüttmann, G. High-Speed Fiber Scanning Endoscope for Volumetric Multi-Megahertz Optical Coherence Tomography. Opt. Lett. 2018, 43, 4386–4389. DOI: 10.1364/OL.43.004386.
  • Do, D.; Yoo, H.; Gweon, D. G. Fiber-Optic Raster Scanning Two-Photon Endomicroscope Using a Tubular Piezoelectric Actuator. J. Biomed. Opt. 2014, 19, 066010. DOI: 10.1117/1.JBO.19.6.066010.
  • Hughes, M.; Yang, G. Z. High Speed, Line-Scanning, Fiber Bundle Fluorescence Confocal Endomicroscopy for Improved Mosaicking. Biomed. Opt. Express 2015, 6, 1241–1252. DOI: 10.1364/BOE.6.001241.
  • Wallace, M. B.; Fockens, P. Probe-Based Confocal Laser Endomicroscopy. Gastroenterology 2009, 136, 1509–1513. DOI: 10.1053/j.gastro.2009.03.034.
  • Guo, T.; Xiong, K.; Zhang, Z.; Li, L.; Yang, S. In Vivo Anatomical Imaging of Colorectum by Tens-of- Micron-Resolved Photoacoustic/Ultrasonic Endoscope. Appl. Phys. Lett. 2021, 118, 153702. DOI: 10.1063/5.0049855.
  • Wang, P.; Chen, Z.; Yang, F.; Yang, S.; Xing, D. Intravascular Tri-Modality System: Combined Ultrasound, Photoacoustic, and Elasticity Imaging. Appl. Phys. Lett. 2018, 113, 253701. DOI: 10.1063/1.5051387.
  • Untracht, G. R.; Karnowski, K.; Sampson, D. D. Imaging the Small with the Small: Prospects for Photonics in Micro-Endomicroscopy for Minimally Invasive Cellular-Resolution Bioimaging. APL Photonics 2021, 6, 060901. DOI: 10.1063/5.0052258.
  • Sparks, H.; Warren, S.; Guedes, J.; Yoshida, N.; Charn, T. C.; Guerra, N.; Tatla, T.; Dunsby, C.; French, P. A Flexible Wide-Field Flim Endoscope Utilising Blue Excitation Light for Label-Free Contrast of Tissue. J. Biophotonics 2015, 8, 168–178. DOI: 10.1002/jbio.201300203.
  • Vyas, K.; Hughes, M.; Rosa, B. G.; Yang, G. Z. Fiber Bundle Shifting Endomicroscopy for High-Resolution Imaging. Biomed. Opt. Express 2018, 9, 4649–4664. DOI: 10.1364/BOE.9.004649.
  • Liu, J.; Zhou, W.; Xu, B.; Yang, X.; Xiong, D. Honeycomb Pattern Removal for Fiber Bundle Endomicroscopy Based on a Two-Step Iterative Shrinkage Thresholding Algorithm. AIP Adv. 2020, 10, 045004. DOI: 10.1063/1.5143929.
  • Lemire-Renaud, S.; Strupler, M.; Benboujja, F.; Godbout, N.; Boudoux, C. Double-Clad Fiber with a Tapered End for Confocal Endomicroscopy. Biomed. Opt. Express 2011, 2, 2961–2972. DOI: 10.1364/BOE.2.002961.
  • Park, H. C.; Song, C.; Jeong, K. H. Micromachined Lens Microstages for Two-Dimensional Forward Optical Scanning. Opt. Express 2010, 18, 16133–16138. DOI: 10.1364/OE.18.016133.
  • Qiu, Z.; Liu, Z.; Duan, X.; Khondee, S.; Joshi, B.; Mandella, M. J.; Oldham, K.; Kurabayashi, K.; Wang, T. D. Targeted Vertical Cross-Sectional Imaging with Handheld Near-Infrared Dual Axes Confocal Fluorescence Endomicroscope. Biomed. Opt. Express 2013, 4, 322–330. DOI: 10.1364/BOE.4.000322.
  • Hui, C.; Albert, C.; Wei Jie, S.; Zhen Dong, S.; John Tw, Y. Closed-Loop Control of a 2-d Mems Micromirror with Sidewall Electrodes for a Laser Scanning Microscope System. Int. J. Optomechatronics 2016, 10, 1–13. DOI: 10.1080/15599612.2015.1095956.
  • Li, Z.; Yang, Z.; Fu, L. Scanning Properties of a Resonant Fiber-Optic Piezoelectric Scanner. Rev. Sci. Instrum. 2011, 82, 123707. DOI: 10.1063/1.3671290.
  • Li, Z.; Fu, L. Note: A Resonant Fiber-Optic Piezoelectric Scanner Achieves a Raster Pattern by Combining Two Distinct Resonances. Rev. Sci. Instrum. 2012, 83, 086102. DOI: 10.1063/1.4739770.
  • Sawinski, J.; Denk, W. Miniature Random-Access Fiber Scanner for in Vivo Multiphoton Imaging. J. Appl. Phys. 2007, 102, 034701. DOI: 10.1063/1.2763945.
  • Lurie, K. L.; Gurjarpadhye, A. A.; Seibel, E. J.; Ellerbee, A. K. Rapid Scanning Catheterscope for Expanded Forward-View Volumetric Imaging with Optical Coherence Tomography. Opt. Lett. 2015, 40, 3165–3168. DOI: 10.1364/OL.40.003165.
  • Zhang, N.; Tsai, T. H.; Ahsen, O. O.; Liang, K.; Lee, H. C.; Xue, P.; Li, X.; Fujimoto, J. G. Compact Piezoelectric Transducer Fiber Scanning Probe for Optical Coherence Tomography. Opt. Lett. 2014, 39, 186–188. DOI: 10.1364/OL.39.000186.
  • Im, J.; Chang, Y.; Song, C. Modified Phase-Offset-Driven Lissajous Scanning Endomicroscopy with a Polyimide-Film-Based Frequency Separator. IEEE/ASME Trans. Mechatronics 2022, 27, 4289–4839. DOI: 10.1109/TMECH.2022.3166453.
  • Liang, W.; Murari, K.; Zhang, Y. Y.; Chen, Y.; Li, X. D.; Li, M. J. Increased Illumination Uniformity and Reduced Photodamage Offered by the Lissajous Scanning in Fiber-Optic Two-Photon Endomicroscopy. J. Biomed. Opt. 2012, 17, 021108. DOI: 10.1117/1.JBO.17.2.021108.
  • Park, H. C.; Seo, Y. H.; Jeong, K. H. Lissajous Fiber Scanning for Forward Viewing Optical Endomicroscopy Using Asymmetric Stiffness Modulation. Opt. Express 2014, 22, 5818–5825. DOI: 10.1364/OE.22.005818.
  • Moon, S.; Lee, S. W.; Rubinstein, M.; Wong, B. J.; Chen, Z. Semi-Resonant Operation of a Fiber-Cantilever Piezotube Scanner for Stable Optical Coherence Tomography Endoscope Imaging. Opt. Express 2010, 18, 21183–21197. DOI: 10.1364/OE.18.021183.
  • Hwang, K.; Seo, Y. H.; Ahn, J.; Kim, P.; Jeong, K. H. Frequency Selection Rule for High Definition and High Frame Rate Lissajous Scanning. Sci. Rep. 2017, 7, 14075. DOI: 10.1038/s41598-017-13634-3.
  • Wu, T.; Ding, Z.; Wang, K.; Chen, M.; Wang, C. Two-Dimensional Scanning Realized by an Asymmetry Fiber Cantilever Driven by Single Piezo Bender Actuator for Optical Coherence Tomography. Opt. Express 2009, 17, 13819–13829. DOI: 10.1364/oe.17.013819.
  • El Rifai, O. M.; Youcef-Toumi, K. Trade-Offs and Performance Limitations in Atomic Force Microscope Feedback System. IFAC Proc. 2002, 35, 185–190. DOI: 10.1016/S1474-6670(17)33939-3.
  • Podgorski, L.; De Meijer, M.; Lanvin, J. D. Influence of Coating Formulation on Its Mechanical Properties and Cracking Resistance. Coatings 2017, 7, 163. DOI: 10.3390/coatings7100163.
  • Xuan, Z.; Tailie, J.; Ngoc San, H.; Nam Seo, G.; Tae Heun, K.; Byung Woon, B.; Han Seo, K.; Ki Won, Y. Performance of Piezo-Stacks for a Piezoelectric Hybrid Actuator by Experiments. J. Intell. Mater. Syst. Struct. 2014, 25, 2212–2220. DOI: 10.1177/1045389X14533439.
  • Khalil, N.; Leo, D. J.; Cudney, H. H. Compact Piezohydraulic Actuation System. Smart Structures and Materials 2000: Industrial and Commercial Applications of Smart Structures Technologies 2000, 3991; pp. 312–322. SPIE Proc. DOI: 10.1117/12.388174.
  • Kuiper, S.; Schitter, G. Active Damping of a Piezoelectric Tube Scanner Using Self-Sensing Piezo Actuation. Mechatronics 2010, 20, 656–665. DOI: 10.1016/j.mechatronics.2010.07.003.
  • Gao, X.; Jie, D.; Shijing, Z.; Li, J.; Yingxiang, L. A Compact 2-Dof Micro/Nano Manipulator Using Single Miniature Piezoelectric Tube Actuator. IEEE Trans. Ind. Electron. 2022, 69, 3928–3937. DOI: 10.1109/TIE.2021.3071698.
  • Vaccarone, R.; Andrea, P.; Rsanna, P. A Cryogenic Scanning Stage with Position Control for a Magnetic Microscope. Phys. B: Condens. Matter 2000, 284–288, 2115–2116. DOI: 10.1016/S0921-4526(99)03015-X.
  • Wischke, M.; Masur, M.; Goldschmidtboeing, F.; Woias, P. Resonance Tunability of Clamped–Free Piezo- Electric Cantilevers. J. Micromech. Microeng. 2009, 19, 125020. DOI: 10.1088/0960-1317/19/12/125020.
  • Van Eysden, C. A.; Sader, J. E. Resonant Frequencies of a Rectangular Cantilever Beam Immersed in a Fluid. J. Appl. Phys. 2006, 100, 114916. DOI: 10.1063/1.2401053.
  • Frick, A.; Sich, D.; Heinrich, G.; Stern, C.; Gössi, M.; Tervoort, T. A. Relationship between Structure and Mechanical Properties of Melt Processable PTFE: Influence of Molecular Weight and Comonomer Content. Macromol. Mater. Eng. 2013, 298, 954–966. DOI: 10.1002/mame.201200172.
  • He, Y.; Chen, W. Experiment and Theoretical Analysis Study of ETFE Inflatable Tubes. Int. J. Aerosp. Eng. 2014, 2014, 1–10. DOI: 10.1155/2014/925428.
  • Birla, M.; Xiyu, D.; Haijun, L.; Miki, L.; Gaoming, L.; Thomas, D. W.; Kenn, R. O. Image Processing Metrics for Phase Identification of a Multiaxis MEMS Scanner Used in Single Pixel Imaging. IEEE ASME Trans. Mechatron. 2021, 26, 1445–1454. DOI: 10.1109/tmech.2020.3020923.
  • Armando, A. J.; Analucia, V. F.; Daniel, P. W.; Mauro, E. B. Phase Maps Retrieval from Sequences of Phase Shifted Images with Unknown Phase Steps Using Generalized n-Dimensional Lissajous Figures—Principles and Applications. Int. J. Optomechatronics 2014, 8, 340–356. DOI: 10.1080/15599612.2014.942933.