A novel method for rapid inspection of sewer networks: combining acoustic and optical means

, , , , , & show all
Pages 3-14 | Received 01 May 2014, Accepted 27 Jun 2015, Published online: 12 Sep 2015

References

  • Arsénio, A.M., Vreeburg, J., and Rietveld, L., 2014. Quantitative non-destructive evaluation of push-fit joints. Urban Water Journal, 11 (8), 657–667.
  • Baum, L.E., 1972. An inequality and associated maximization technique in statistical estimation for probabilistic functions of Markov processes. Inequalities, 3, 1–8.
  • Bin Ali, M.T., 2010. Development of acoustic sensor and signal processing technique. Unpublished thesis (PhD). University of Bradford, Bradford, UK.
  • Busnello, L., 2011. Utilization of zoom camera technology in municipal sewer system maintenance. Basement flood symposium, 26 May 2011. Toronto, ON: Toronto Board of Trade.
  • Chae, M.J., Kim, W., and Hwang, H.-K., 2008. Digital pipeline image scanning and intelligent data management for sewer pipelines. In: Proceedings of Pipelines Congress 2008 – Pipeline Asset Management: Maximizing Performance of our Pipeline Infrastructure (Volume 321). July 2008. Atlanta, GA: American Society of Civil Engineers, 1–11.
  • Deserno, T. M., et al., 2010. Visualization and analysis of medical ultrasound processing applied to ground-penetrating radar. Water Asset Management International, 6 (3), 14–20.
  • Dirksen, J., et al., 2013. The consistency of visual sewer inspection data. Structure and Infrastructure Engineering, Maintenance, Management, Life-Cycle Design and Performance, 9 (3), 214–228.
  • Duran, O., Althoefer, K., and Seneviratne, L. D., 2003. Pipe inspection using a laser-based transducer and automated analysis techniques. IEEE/ASME Transactions on Mechatronics, 3, 401–409.
  • EN 13508–2, A1, 2010. Condition of drain and sewer systems outside buildings — part 2 visual inspection coding system. Brussels: CEN.
  • EPA, 2010. Innovative internal camera inspection and data management for effective condition assessment of collection systems, EPA/600/R-10-082. Washington, DC: U.S. Environmental Protection Agency.
  • Gooch, R. M., Clarke, A., and Ellis, T. J., 1996. A semi-autonomous sewer surveillance and inspection vehicle. Proc IEEE Intelligent Vehicles, Japan, 64–89.
  • Guo, W., Soibelman, L., and Garrett, J. H., Jr., 2009. Automated defect detection for sewer pipeline inspection and condition assessment. Automation in Construction, 18, 587–596.
  • Horoshenkov, K. V., Long, R. J., and Tait, S. J., 2010. Improvements in and relating to apparatus for the airborne acoustic inspection of pipes. Patent Application WO2010020817, 25/02/2010, International Bureau of World Intellectual Property Organization (WIPO), Geneva, Switzerland.
  • Horoshenkov, K., 2013. Promotion video for SewerBatt®. University of Bradford, UK.
  • INNOKANIS, 2015. Innovative inspection methods for optimisation of selective sewer operation strategies research project. Vienna, Austria, The Austrian Federal Ministry of Agriculture, Forestry, Environment and Water Management. Available from: http://www.bmlfuw.gv.at/publikationen/wasser/abwasser/INNOKANIS.html.
  • MesSen Nord, 2013. Anwendungsflyer: Schacht-Zoom-Kamera STV-3 ( Application brochure: manhole-zoom camera STV-3). Available from: http://www.messennord.de/fileadmin/Media/PDF/STV3-Anwendungsflyer.pdf.
  • Mueller, K., and Fischer, B., 2007. Objective condition assessment of sewer systems. Proceedings of IWA LESAM 2007, IWA - International Water Association, Lisbon, Portugal, 1–13.
  • Pamperl, E., et al., 2010. Anwendung einer Schacht-Zoom-Kamera für die bauliche und betriebliche Inspektion von Kanälen (Employing a manhole-zoom camera for the structural and operational inspection of sewer systems). Wiener Mitteilungen, 220, B1–22.
  • Plihal, H., Kuratko, A., and Ertl, Th., 2014. Einsatz des elektronischen Spiegels für den betrieblichen Überblick im Kanalsystem (Application of a manhole-zoom camera for an operational overview of the sewer system). Austrian Water and Waste Management OEWAW, 3–4, 103–111.
  • Rinner, J., Pryputniewicz, S., and Mitchell, J. C., 2008. To zoom or not to zoom. Journal of New England Water Environment Association, 42 (4), 20–23.
  • Romanova, A., 2009. Hydraulic flows in pipes and acoustic response analysis Unpublished thesis (BEng). University of Bradford, Bradford, UK.
  • Romanova, A., et al., 2013. Sewer inspection and comparison of acoustic and CCTV methods. Proceedings of the Institution of Civil Engineers: Water Management, 166 (2), 70–80.
  • Sousa, V., et al., 2014. Comparison of the inspector and rating protocol uncertainty influence in the condition rating of sewers. Water Science & Technology, 69 (4), 862–867.
  • Wang, Y. J., et al., 2013. Study and Practice in China of a New Sewer Inspection and Assessment Method Combining Hand-held Camera and Closed Circuit Television. In Proceedings of the 7th International Conference on Sewer Processes and Networks Sheffield - August 2013. Sheffield, UK: Pennine Water Group, University of Sheffield and University of Bradford, 369–376.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.