References
- Joy, M, Scott, G, and Henkelman, M, 1989. In vivo detection of applied electric currents by magnetic resonance imaging, Magn. Reson. Imaging 7 (1989), pp. 89–94.
- Scott, GC, Joy, MLG, Armstrong, RL, and Henkelman, RM, 1991. Measurement of nonuniform current density by magnetic resonance, IEEE Trans. Med. Imaging 10 (1991), pp. 362–374.
- Eyuboglu, M, 2006. "Magnetic resonance electrical impedance tomography". In: Akay, M, ed. Wiley Encylopedia of Biomedical Engineering. New York: Wiley & Sons; 2006. pp. 2154–2162.
- Woo, EJ, and Seo, JK, 2008. Magnetic resonance electrical impedance tomography (MREIT) for high‐resolution conductivity imaging, Physiol. Meas. 29 (2008), pp. R1–R26.
- Eyuboglu, M, Reddy, R, and Leigh, JS, 1998. Imaging electrical current density using nuclear magnetic resonance, Elektrik 6 (1998), pp. 201–214.
- Oh, SH, Chun, IK, Lee, SY, Cho, MH, and Mun, CW, 2003. A single current density component imaging by MRCDI without subject rotations, Magn. Reson. Imaging 21 (2003), pp. 1023–1028.
- Oh, SH, Lee, BI, Woo, EJ, Lee, SY, Cho, MH, Kwon, O, and Seo, JK, 2003. Conductivity and current density image reconstruction using harmonic Bz algorithm in magnetic resonance impedance tomography, Phys. Med. Biol. 48 (2003), pp. 3101–3116.
- Seo, JK, Kwon, O, Lee, BI, and Woo, EJ, 2003. Reconstruction of current density distributions in axially symmetric cylindrical sections using only one component of magnetic flux density: Computer simulation study, Physiol. Meas. 24 (2003), pp. 565–577.
- Seo, JK, Yoon, JR, Woo, EJ, and Kwon, O, 2003. Reconstruction of conductivity and current density images using only one component of magnetic field measurements, IEEE Trans. Biomed. Eng. 50 (2003), pp. 1121–1124.
- Pyo, HC, Kwon, O, Seo, JK, and Woo, EJ, 2005. Identification of current density distribution in electrically conducting subject with anisotropic conductivity distribution, Phys. Med. Biol. 50 (2005), pp. 3183–3196.
- Ider, YZ, Birgul, O, Oran, OF, Arikan, O, Hamamura, MJ, and Muftuler, LT, 2010. Fourier transform magnetic resonance current density imaging (FT‐MRCDI) from one component of magnetic flux density, Phys. Med. Biol. 55 (2010), pp. 3177–3199.
- Park, C, Lee, BI, and Kwon, OI, 2007. Analysis of recoverable current from one component of magnetic flux density in MREIT and MRCDI, Phys. Med. Biol. 52 (2007), pp. 3001–3013.
- Scott, GC, Joy, MLG, Armstrong, RL, and Henkelman, RM, 1992. Sensitivity of magnetic resonance current density imaging, J. Magn. Reson. 97 (1992), pp. 235–254.
- Birgul, O, Eyuboglu, M, and Ider, YZ, 2003. Current constrained voltage scaled reconstruction (CCVSR) algorithm for MR‐EIT and its performance with different probing current patterns, Phys. Med. Biol. 48 (2003), pp. 653–671.
- Kwon, O, Woo, EJ, Yoon, JR, and Seo, JK, 2002. Magnetic Resonance Electrical Impedance Tomography (MREIT): Simulation study of J‐substitution algorithm, IEEE Trans. Biomed. Eng. 49 (2002), pp. 160–167.
- Boyacıoğlu, R, 2009. Performance evaluation of current density based magnetic resonance electrical impedance tomography reconstruction algorithms. Ankara: MSc thesis, Middle East Technical University; 2009.
- Ersoz, A, 2010. Magnetic resonance current density imaging using one component of magnetic flux density. Ankara: MSc thesis, Middle East Technical University; 2010.