406
Views
12
CrossRef citations to date
0
Altmetric
Device Profile

Τhe AFX unibody bifurcated unibody aortic endograft for the treatment of abdominal aortic aneurysms: current evidence and future perspectives

, , , , , ORCID Icon, & show all
Pages 5-15 | Received 02 Oct 2019, Accepted 10 Dec 2019, Published online: 20 Dec 2019

References

  • Chaikof EL, Dalman RL, Eskandari MK, et al. The society for vascular surgery practice guidelines on the care of patients with an abdominal aortic aneurysm. J Vasc Surg. 2018;67(1):2–77.
  • Multicentre Aneurysm Screening Study Group, Ashton HA, Buxton MJ, Day NE, et al. The Multicentre Aneurysm Screening Study (MASS) into the effect of abdominal aortic aneurysm screening on mortality in men: a randomised controlled trial. Lancet 2002;360(9345):1531–1539.
  • Budtz-Lilly J, Wanhainen A, Mani K. Outcomes of endovascular aortic repair in the modern era. J Cardiovasc Surg (Torino). 2018;59(2):180–189.
  • Kent KC. Clinical practice. Abdominal aortic aneurysms. N Engl J Med. 2014;371(22):2101–2108.
  • Stather PW, Sidloff DA, Rhema I, et al. A review of current reporting of abdominal aortic aneurysm mortality and prevalence in the literature. Eur J Vasc Endovasc Surg. 2014;47(3):240–242.
  • Schoretsanitis N, Georgakarakos E, Argyriou C, et al. A critical appraisal of endovascular stent-grafts in the management of abdominal aortic aneurysms. Radiol Med. 2017;122(4):309–318.
  • Powell A, Kashyap VS. Design and clinical considerations for endovascular stent grafts. Interv Cardiol Clin. 2016 Jul;5(3):381–389.
  • EVAR trial investigators, Patel R, Sweeting MJ, Powell JT, et al. Endovascular versus open repair of abdominal aortic aneurysm in 15-years’ follow-up of the UK endovascular aneurysm repair trial 1 (EVAR trial 1): a randomised controlled trial. Lancet. 2016;388(10058):2366–2374.
  • EVAR-1, DREAM, OVER and ACE Trialists, Powell JT, Sweeting MJ, Ulug P, et al. Meta-analysis of individual-patient data from EVAR-1, DREAM, OVER and ACE trials comparing outcomes of endovascular or open repair for abdominal aortic aneurysm over 5 years. Br J Surg. 2017;104(3):166–178.
  • Kontopodis N, Papadopoulos G, Galanakis N, et al. Improvement of patient eligibility with the use of new generation endografts for the treatment of abdominal aortic aneurysms. A comparison study among currently used endografts and literature review. Expert Rev Med Devices. 2017;14(3):245–250.
  • Schoretsanitis N, Argyriou C, Georgiadis GS, et al. Hostile neck in abdominal aortic aneurysms: does it still exist? Vasc Endovascular Surg. 2016;50(4):208–210.
  • Avgerinos ED, Dalainas I, Kakisis J, et al. Endograft accommodation on the aortic bifurcation: an overview of anatomical fixation and implications for long-term stent-graft stability. J Endovasc Ther. 2011 Aug;18(4):462–470.
  • Diethrich EB. Novel sealing concept in the Endologix AFX unibody stent-graft. J Cardiovasc Surg (Torino). 2014;55(1):93–102.
  • Perdikides TP, Avgerinos ED, Lagios K, et al. Improving endograft stability by accommodation onto the aortic bifurcation. J Endovasc Ther. 2007;14(5):634–638.
  • Welborn MB 3rd, McDaniel HB, Johnson RC, et al. Clinical outcome of an extended proximal seal zone with the AFX endovascular aortic aneurysm system. J Vasc Surg. 2014;60(4):876–883.
  • Trellopoulos G, Georgiadis GS, Nikolopoulos ES, et al. Current tips for ensuring successful transfemoral short limb cannulation in modular aortic endografts: a new method for incorporation in practice. Perspect Vasc Surg Endovasc Ther. 2009;21(4):232–236.
  • Coppi G, Silingardi R, Tasselli S, et al. Endovascular treatment of abdominal aortic aneurysms with the powerlink endograft system: influence of placement on the bifurcation and use of a proximal extension on early and late outcomes. J Vasc Surg. 2008;48(4):795–801.
  • Qu L, Raithel D. From clinical trials to clinical practice: 612 cases treated with the powerlink stent-graft for endovascular repair of AAA. J Cardiovasc Surg (Torino). 2009;50(2):131–137.
  • Jordan WD Jr, Moore WM Jr, Melton JG, et al. Secure fixation following EVAR with the Powerlink XL System in wide aortic necks: results of a prospective, multicenter trial. J Vasc Surg. 2009;50(5):979–986.
  • Endologix Investigators, Wang GJ, Carpenter JP. The powerlink system for endovascular abdominal aortic aneurysm repair: six-year results. J Vasc Surg. 2008;48(3):535–545.
  • Skibba AA, Evans JR, Greenfield DT, et al. Management of late main-body aortic endograft component uncoupling and type IIIa endoleak encountered with the Endologix Powerlink and AFX platforms. J Vasc Surg. 2015;62(4):868–875.
  • Melas N, Stavridis K, Saratzis A, et al. Active proximal sealing in the endovascular repair of abdominal aortic aneurysms: early results with a new stent-graft. J Endovasc Ther. 2015;22(2):174–178.
  • Lemmon GW, Motaganahalli RL, Chang T, et al. Failure mode analysis of the Endologix endograft. J Vasc Surg. 2016;64(3):571–576.
  • Groot Jebbink E, Mathai V, Boersen JT, et al. Hemodynamic comparison of stent configurations used for aortoiliac occlusive disease. J Vasc Surg. 2017;66(1):251–260.
  • Boersen JT, Groot Jebbink E, Versluis M, et al. Flow and wall shear stress characterization after endovascular aneurysm repair and endovascular aneurysm sealing in an infrarenal aneurysm model. J Vasc Surg. 2017;66(6):1844–1853.
  • Casciaro ME, Dottori J, El-Batti S, et al. Effects on aortoiliac fluid dynamics after endovascular sealing of abdominal aneurysms. Vasc Endovascular Surg. 2018;52(8):621–628.
  • Raptis A, Xenos M, Kouvelos G, et al. Haemodynamic performance of AFX and Nellix endografts: a computational fluid dynamics study. Interact Cardiovasc Thorac Surg. 2018;26(5):826–833.
  • van Noort K, Holewijn S, Schuurmann RCL, et al. Effect of abdominal aortic endoprostheses on arterial pulse wave velocity in an in vitro abdominal aortic flow model. Physiol Meas. 2018;39(10):104001.
  • Kadoglou NP, Moulakakis KG, Papadakis I, et al. Differential effects of stent-graft fabrics on arterial stiffness in patients undergoing endovascular aneurysm repair. J Endovasc Ther. 2014;21(6):850–858.
  • Molony DS, Kavanagh EG, Madhavan P, et al. A computational study of the magnitude and direction of migration forces in patient-specific abdominal aortic aneurysm stent-grafts. Eur J Vasc Endovasc Surg. 2010;40(3):332–339.
  • Figueroa CA, Taylor CA, Yeh V, et al. Effect of curvature on displacement forces acting on aortic endografts: a 3-dimensional computational analysis. J Endovasc Ther. 2009;16(3):284–294.
  • Krämer SC, Seifarth H, Pamler R, et al. Geometric changes in aortic endografts over a 2-year observation period. J Endovasc Ther. 2001;8(1):34–38.
  • Chen PL, Hsu HL, Chen IM, et al. The impact of aortic tortuosity on delayed type i or iii endoleak after endovascular aortic repair. Ann Vasc Surg. 2017;41:110–117.
  • Pitoulias GA, Valdivia AR, Hahtapornsawan S, et al. Conical neck is strongly associated with proximal failure in standard endovascular aneurysm repair. J Vasc Surg. 2017;66(6):1686–1695.
  • Malas MB, Ohki T, Veith FJ, et al. Absence of proximal neck dilatation and graft migration after endovascular aneurysm repair with balloon-expandable stent-based endografts. J Vasc Surg. 2005;42(4):639–644.
  • Savlovskis J, de Vries Krievins JP, Holden A, et al. Aortic neck enlargement after endovascular aneurysm repair using balloon-expandable versus self-expanding endografts. J Vasc Surg. 2015;62(3):541–549.
  • TriVascular Ovation Italian Study, de Donato G, Setacci F, Bresadola L, et al. Aortic neck evolution after endovascular repair with trivascular ovation stent graft. J Vasc Surg. 2016;63(1):8–15.
  • Matsagkas MI, Kouvelos G, Spanos K, et al. Double fixation for abdominal aortic aneurysm repair using AFX body and Endurant proximal aortic cuff: mid-term results. Interact Cardiovasc Thorac Surg. 2017;25(1):1–5.
  • Helo N, Chang AC, Hyun C, et al. Retrospective review of billowing phenomenon-A mimic of endoleak following placement of endologix covered stent for the treatment of abdominal aortic aneurysm. Ann Vasc Surg. 2017;45:239–246.
  • Chang H, Hadro NC, Norris MA, et al. The progression of billowing of Endologix AFX2® abdominal aortic aneurysm device as a precursor for the rupture of an abdominal aortic aneurysm. Ann Vasc Surg. 2019;54(335):e11–e14.
  • Wu A, Karuppasamy K, Wang W. Billowing of Endologix powerlink stent mimicking endoleaks. Res Cardiovasc Med. 2016;5(2):e32448.
  • Kwon J, Dimuzio P, Salvatore D, et al. Incidence of stent graft failure from type IIIB endoleak in contemporary endovascular abdominal aortic aneurysm repair. J Vasc Surg. DOI:10.1016/j.jvs.2019.06.183
  • Food and Drug Administration. Endologix, Inc. Recalls AFX Endovascular AAA Systems due to risk of type III endoleaks. [cited 2019 Dec 2]. Available from: https://www.fda.gov/medical-devices/medicaldevice-recalls/endologix-inc-recalls-afx-endovascular-aaasystems-due-risk-type-iii-endoleaks

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.