References
- Lloyd-Jones D, Adams RJ, Brown TM, et al. Executive summary: heart disease and stroke statistics—2010 update: a report from the American Heart Association. Circulation. 2010;121(7):948–954.
- Smith SC Jr., Dove JT, Jacobs AK, et al. ACC/AHA guidelines of percutaneous coronary interventions (revision of the 1993 PTCA guidelines)–executive summary. A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (committee to revise the 1993 guidelines for percutaneous transluminal coronary angioplasty). J Am Coll Cardiol. 2001;37(8):2215–2239.
- Syed MA, Carlson K, Murphy M, et al. Long-term safety of cardiac magnetic resonance imaging performed in the first few days after bare-metal stent implantation. J Magn Reson Imaging. 2006;24(5):1056–1061.
- Kanal E, Barkovich AJ, Bell C, et al. ACR guidance document for safe MR practices: 2007. AJR Am J Roentgenol. 2007;188(6):1447–1474.
- Gerber TC, Fasseas P, Lennon RJ, et al. Clinical safety of magnetic resonance imaging early after coronary artery stent placement. J Am Coll Cardiol. 2003;42(7):1295–1298.
- American College of Cardiology Foundation Task Force on Expert Consensus D, Hundley WG, Bluemke DA, Finn JP, et al. ACCF/ACR/AHA/NASCI/SCMR 2010 expert consensus document on cardiovascular magnetic resonance: a report of the American college of cardiology foundation task force on expert consensus documents. J Am Coll Cardiol. 2010;55(23):2614–2662.
- Müllerleile K, Kolb C, Rittger H, et al. Passive kardiovaskuläre Implantate in der Magnetresonanztomographie. Der Kardiologe. 2015;9(4):303–309.
- Levine GN, Gomes AS, Arai AE, et al. Safety of magnetic resonance imaging in patients with cardiovascular devices: an American Heart Association scientific statement from the committee on diagnostic and interventional cardiac catheterization, council on clinical cardiology, and the council on cardiovascular radiology and intervention: endorsed by the American college of cardiology foundation, the North American society for cardiac imaging, and the society for cardiovascular magnetic resonance. Circulation. 2007;116(24):2878–2891.
- Sinitsyn VE, Stukalova OV, Kupriianova OM, et al. [Safety of magnetic resonance imaging after coronary stenting]. Kardiologiia. 2007;47(6):94–96.
- Gualandro DM, Shiozaki AA, Rochitte CE. [Safety of magnetic resonance imaging after coronary angioplasty with stent]. Rev Assoc Med Bras (1992). 2008;54(4):287–288.
- Shellock FG, Curtis JS. MR imaging and biomedical implants, materials, and devices: an updated review. Radiology. 1991;180(2):541–550.
- Shellock FG. Biomedical implants and devices: assessment of magnetic field interactions with a 3.0-Tesla MR system. J Magn Reson Imaging. 2002;16(6):721–732.
- Kotsakis A, Tan KH, Jackson G. Is MRI a safe procedure in patients with coronary stents in situ? Int J Clin Pract. 1997;51(6):349.
- Sincleair ST. Is MRI contraindicated after coronary stent placement? Postgrad Med. 2006;119(3):83–84.
- Hug J, Nagel E, Bornstedt A, et al. Coronary arterial stents: safety and artifacts during MR imaging. Radiology. 2000;216(3):781–787.
- Sommer T, Maintz D, Schmiedel A, et al. [High field MR imaging: magnetic field interactions of aneurysm clips, coronary artery stents and iliac artery stents with a 3.0 Tesla MR system]. Rofo. 2004;176(5):731–738.
- Shellock FG, Forder JR. Drug eluting coronary stent: in vitro evaluation of magnet resonance safety at 3 Tesla. J Cardiovasc Magn Reson. 2005;7(2):415–419.
- Shellock FG, Shellock VJ. Metallic stents: evaluation of MR imaging safety. AJR Am J Roentgenol. 1999;173(3):543–547.
- Schroeder AP, Houlind K, Pedersen EM, et al. Magnetic resonance imaging seems safe in patients with intracoronary stents. J Cardiovasc Magn Reson. 2000;2(1):43–49.
- Patel MR, Albert TS, Kandzari DE, et al. Acute myocardial infarction: safety of cardiac MR imaging after percutaneous revascularization with stents. Radiology. 2006;240(3):674–680.
- Tejedor-Vinuela P, San Roman-Calvar JA, Duran-Hernandez JM, et al. [Safety of early cardiac magnetic resonance imaging in acute myocardial infarction patients with stents]. Rev Esp Cardiol. 2006;59(12):1261–1267.
- Curtis JW, Lesniak DC, Wible JH, et al. Cardiac magnetic resonance imaging safety following percutaneous coronary intervention. Int J Cardiovasc Imaging. 2013;29(7):1485–1490.
- Jehl J, Comte A, Aubry S, et al. Clinical safety of cardiac magnetic resonance imaging at 3 T early after stent placement for acute myocardial infarction. Eur Radiol. 2009;19(12):2913–2918.
- Porto I, Selvanayagam J, Ashar V, et al. Safety of magnetic resonance imaging one to three days after bare metal and drug-eluting stent implantation. Am J Cardiol. 2005;96(3):366–368.
- Kaya MG, Okyay K, Yazici H, et al. Long-term clinical effects of magnetic resonance imaging in patients with coronary artery stent implantation. Coron Artery Dis. 2009;20(2):138–142.
- Nijveldt R, Hirsch A, Hofman MB, et al. 3.0 T cardiovascular magnetic resonance in patients treated with coronary stenting for myocardial infarction: evaluation of short term safety and image quality. Int J Cardiovasc Imaging. 2008;24(3):283–291.
- Parthasarathy H, Saeed O, Marcuzzi D, et al. MRI-induced stent dislodgment soon after left main coronary artery stenting. Circ Cardiovasc Interv. 2013;6(5):e58–9.
- Habib A, Finn AV. Endothelialization of drug eluting stents and its impact on dual anti-platelet therapy duration. Pharmacol Res. 2015;93:22–27.