- Adrian M J, Roy W E, Karpovich P V. Normal gait of the dog: an electrogoniometric study. Am J Vet Res 1966; 27: 90-5
- Aerssens J, Boonen S, Lowet G, Dequeker J. Interspecies differences in bone composition, density, and quality: potential implications for in vivo bone research. Endocrinology 1998; 139: 663-70
- Altman D G. Practical statistics for medical research. 8 ed. Chapman and Hall/CRC. 1999; 126
- Baddeley A J, Gundersen H J, Cruz-Orive L M. Estimation of surface area from vertical sections. J Microsc 1986; 142: 259-76
- Breusch S J, Norman T L, Revie I C, Lehner B, Caillouette J T, Schneider U, Blaha J D, Lukoschek M. Cement penetration in the proximal femur does not depend on broach surface finish. Acta Orthop Scand 2001; 72: 29-35
- Channer M A, Glisson R R, Seaber A V, Vail T P. Use of bone compaction in total knee arthroplasty. J Arthroplasty 1996; 11: 743-9
- Chareancholvanich K, Bourgeault C, Schmidt A H, Gustilo R, Lew W. In Vitro Stability of Cemented and Cementless Femoral Stems With Compaction. Clin Orthop 2002, 394: 290-302
- Dhert W J, Verheyen C C, Braak L H, de Wijn J R, Klein C P, de Groot K, Rozing P M. A finite element analysis of the push-out test: influence of test conditions. J Biomed Mater Res 1992; 26: 119-30
- Dhert W J, Thomsen P, Blomgren A K, Esposito M, Ericson L E, Verbout A J. Integration of press-fit implants in cortical bone: a study on interface kinetics. J Biomed Mater Res 1998; 41: 574-83
- Gotfredsen K, Budtz-Jorgensen E, Jensen L N. A method for preparing and staining histological sections containing titanium implants for light microscopy. Stain Technol 1989; 64: 121-7
- Green J R, Nemzek J A, Arnoczky S P, Johnson L L, Balas M S. The effect of bone compaction on early fixation of porous-coated implants. J Arthroplasty 1999; 14: 91-7
- Gundersen H J, Bendtsen T F, Korbo L, Marcussen N, Moller A, Nielsen K, Nyengaard J R, Pakkenberg B, Sorensen F B, Vesterby A. Some new, simple and efficient stereological methods and their use in pathological research and diagnosis. APMIS 1988; 96: 379-94
- Hofmann A A, Plaster R L, Murdock L E. Subvastus (Southern) approach for primary total knee arthroplasty. Clin Orthop 1991, 269: 70-7
- Kärrholm J, Malchau H, Snorrason F, Herberts P. Micromotion of femoral stems in total hip arthroplasty. A randomized study of cemented, hydroxyapatite-coated, and porous-coated stems with roentgen stereophotogrammetric analysis. J Bone Joint Surg (Am) 1994; 76(11)1692-705
- Kärrholm J, Herberts P, Hultmark P, Malchau H, Nivbrant B, Thanner J Radiostereometry of hip prostheses. Review of methodology and clinical results. Clin Orthop 1997, 344: 94-110
- Kienapfel H, Sumner D R, Turner T M, Urban R M, Galante J O. Efficacy of autograft and freeze-dried allograft to enhance fixation of porous coated implants in the presence of interface gaps. J Orthop Res 1992; 10: 423-33
- Kimmel D B, Jee W S. A quantitative histologic study of bone turnover in young adult beagles. Anat Rec 1982; 203: 31-45
- Kold S, Bechtold J E, Ding M, Chareancholvanich K, Rahbek O, Søballe K. Compacted cancellous bone has a spring-back effect. Acta Orthop Scand 2003a; 74: 591-5
- Kold S, Mouzin O, Bourgeault C, Søballe K, Bechtold J E. Femoral fracture risk in hip arthroplasty: smooth versus toothed instruments. Clin Orthop 2003b, 408: 180-8
- Kold S, Rahbek O, Toft M, Ding M, Overgaard S, Søballe K. Bone compaction enhances implant fixation in a canine gap model. J Orthop Res 2005a; 23: 824-30
- Kold S, Rahbek O, Toft M, Overgaard S, Søballe K. Bone compaction enhances fixation of weight-bearing hydroxy-apatite-coated implants. J Arthroplasty accepted 2005b
- Kold S, Rahbek O, Toft M, Overgaard S, Søballe K. Bone compaction enhances fixation of weight-bearing titanium implants. Clin Orthop 2005c, 431: 138-44
- Kold S, Rahbek O, Zippor B, Bechtold J E, Søballe K. Bone compaction enhances fixation of hydroxyapatite coated implants in a canine gap model. J Biomed Mat Res: B 2005d;; 75: 49-55
- Kold S, Bechtold J E, Mouzin O, Bourgeault C, Søballe K. Importance of pre-clinical testing exemplified by femoral fractures in vitro with new bone preparation technique. Clin Biomech 2005e; 20: 77-82
- Mouzin O, Søballe K, Bechtold J E. Loading improves anchorage of hydroxyapatite implants more than titanium implants. J Biomed Mater Res 2001; 58: 61-8
- Nelissen R G, Valstar E R, Rozing P M. The effect of hydroxyapatite on the micromotion of total knee prostheses. A prospective, randomized, double-blind study. J Bone Joint Surg (Am) 1998; 80(11)1665-72
- Önsten I, Nordqvist A, Carlsson A S, Besjakov J, Shott S. Hydroxyapatite augmentation of the porous coating improves fixation of tibial components. A randomised RSA study in 116 patients. J Bone Joint Surg (Br) 1998; 80(3)417-25
- Overgaard S, Søballe K, Gundersen H J. Efficiency of systematic sampling in histomorphometric bone research illustrated by hydroxyapatite-coated implants: optimizing the stereological vertical-section design. J Orthop Res 2000; 18: 313-21
- Ramamurti B S, Orr T E, Bragdon C R, Lowenstein J D, Jasty M, Harris W H. Factors influencing stability at the interface between a porous surface and cancellous bone: a finite element analysis of a canine in vivo micromotion experiment. J Biomed Mater Res 1997; 36(2)274-80
- Regner L, Carlsson L, Karrholm J, Herberts P. Tibial component fixation in porous- and hydroxyapatite-coated total knee arthroplasty: a radiostereometric evaluation of migration and inducible displacement after 5 years. J Arthroplasty 2000; 15(6)681-9
- Ryd L, Albrektsson B E, Carlsson L, Dansgard F, Herberts P, Lindstrand A, Regner L, Toksvig-Larsen S. Roentgen stereophotogrammetric analysis as a predictor of mechanical loosening of knee prostheses. J Bone Joint Surg (Br) 1995; 77(3)377-83
- Søballe K, Hansen E S, Brockstedt-Rasmussen H, Pedersen C M, Bunger C. Hydroxyapatite coating enhances fixation of porous coated implants. A comparison in dogs between press fit and noninterference fit. Acta Orthop Scand 1990; 61(4)299-306
- Søballe K, Hansen E S, Brockstedt-Rasmussen H, Hjortdal V E, Juhl G I, Pedersen C M, Hvid I, Bunger C. Fixation of titanium- and hydroxyapatite coated implants in arthritic osteopenic bone. J Arthroplasty 1991; 6(4)307-16
- Søballe K, Toksvig-Larsen S, Gelineck J, Fruensgaard S, Hansen E S, Ryd L, Lucht U, Bunger C. Migration of hydroxyapatite coated femoral prostheses. A Roentgen Stereophotogrammetric study. J Bone Joint Surg (Br) 1993; 75(5)681-7
- Toksvig-Larsen S, Jorn L P, Ryd L, Lindstrand A. Hydroxy-apatite-enhanced tibial prosthetic fixation. Clin Orthop 2000, 370: 192-200
- Vail T, Channer M, Glisson R. The effect of bone cavity preparation method on implant fixation. Trans Orthop Res 2000; 25: 530
- Wang J S, Tägil M, Aspenberg P. Load-bearing increases new bone formation in impacted and morselized allografts. Clin Orthop 2000, 378: 274-81
Free access
No adverse effects of bone compaction on implant fixation after resorption of compacted bone in dogs
Reprints and Corporate Permissions
Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?
To request a reprint or corporate permissions for this article, please click on the relevant link below:
Academic Permissions
Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?
Obtain permissions instantly via Rightslink by clicking on the button below:
If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.
Related research
People also read lists articles that other readers of this article have read.
Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.
Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.