- Akisue T, Bauer T W, Yamaguchi M, Matejczyk M B, Stulberg B N, Wilde A H. Multidirectional deformation in fully congruent acetabular components. J Arthroplasty 1999; 14: 1011–8
- Anda S, Svenningsen S, Grontvedt T, Benum P. Pelvic inclination and spatial orientation of the acetabulum. A radiographic, computed tomographic and clinical investigation. Acta Radiol 1990; 31: 389–94
- Barrack R L, Castro F P, Szuszczewicz E S, Schmalzried T P. Analysis of retrieved uncemented porous-coated acetabular components in patients with and without pelvic osteolysis. Orthopedics 2002; 25: 1373–8
- Bragdon C R, Thanner J, Greene M E, Malchau H, Digas G, Harris W H, Karrholm J. Standing versus supine radiographs in RSA evaluation of femoral head penetration. Clin Orthop 2006, 448: 46–51
- Charnley J, Halley D K. Rate of Wear in Total Hip-Replacement. Clin Orthop 1975, 112: 170–9
- Charnley J, Kamangar A, Longfiel M D. Optimum Size of Prosthetic Heads in Relation to Wear of Plastic Sockets in Total Replacement of Hip. Med Biol Eng 1969; 7: 31–9
- Collier M B, Kraay M J, Rimnac C M, Goldberg V M. Evaluation of contemporary software methods used to quantify polyethylene wear after total hip arthroplasty. J Bone Joint Surg (Am) 2003; 85: 2410–8
- Derbyshire B. The estimation of acetabular cup wear volume from two-dimensional measurements: a comprehensive analysis. Proc Inst Mech Eng 1998; 212: 281–91
- Devane P A, Bourne R B, Rorabeck C H, Hardie R M, Horne J G. Measurement of polyethylene wear in metal-backed acetabular cup. 1.3-dimensional technique. Clin Orthop 1995, 319: 303–16
- Dowd J E, Sychterz C J, Young A M, Engh C A. Characterization of long-term femoral-head-penetration rates. Association with and prediction of osteolysis. J Bone Joint Surg (Am) 2000; 82: 1102–7
- Foss O A, Klaksvik J, Benum P, Anda S. Pelvic rotations: A pelvic phantom study. Acta Radiol 2007a; 48: 650–7
- Foss O A, Klaksvik J, Benum P, Anda S. The rotation ratios method: A method to describe altered pelvic orientation in sequential radiographs. Acta Radiol 2007b; 48: 1011–9
- Foss O A, Klaksvik J, Benum P, Anda S. Validation of the rotation ratios method. Acta Radiol 2007c; 48: 658–64
- Hui A J, McCalden F W, Martell J M, MacDonald S J, Bourne R B, Rorabeck C H. Validation of two and threedimensional radiographic techniques for measuring polyethylene wear after total hip arthroplasty. J Bone Joint Surg (Am) 2003; 85: 505–11
- Kabo J M, Gebhard J S, Loren G, Amstutz H C. In vivo wear of polyethylene acetabular components. J Bone Joint Surg (Br) 1993; 75: 254–8
- Katz J F. Precise Identification of radiographic acetabular landmarks. Clin Orthop 1979, 141: 166–8
- Maloney W J, Peters P, Engh C A, Chandler H. Severe osteolysis of the pelvis in association with acetabular replacement without cement. J Bone Joint Surg (Am) 1993; 75: 1627–35
- Martell J M, Berdia S. Determination of polyethylene wear in total hip replacements with use of digital radiographs. J Bone Joint Surg (Am) 1997; 79: 1635–41
- Martell J M, Leopold S S, Liu X. The effect of joint loading on acetabular wear measurement in total hip arthroplasty. J Arthroplasty 2000; 15: 512–8
- Moore K D, Barrack R L, Sychterz C J, Sawhney J, Yang A M, Engh C A. The effect of weight-bearing on the radiographic measurement of the position of the femoral head after total hip arthroplasty. J Bone Joint Surg (Am) 2000; 82: 62–9
- Orishimo K F, Claus A M, Sychterz C J. Relationship between polyethylene wear and osteolysis in hips with a second-generation porous-coated cementless cup. J Bone Joint Surg (Am) 2004; 86: 1095–9
- Shetty V D, Villar R N. Development and problems of metalon-metal hip arthroplasty. Proc Inst Mech Eng 2006; 220: 371–7
- Siebenrock K A, Kalbermatten D F, Ganz R. Effect of pelvic tilt on acetabular retroversion: A study of pelves from cadavers. Clin Orthop 2003, 407: 241–8
- Smith P N, Ling R S, Taylor R. The in.uence of weightbearing on the measurement of polyethylene wear in THA. J Bone Joint Surg (Br) 1999; 81: 259–65
- Sychterz C J, Engh C A, Shah N, Engh C A. Radiographic evaluation of penetration by the femoral head into the polyethylene liner over time. J Bone Joint Surg (Am) 1997; 79: 1040–6
- Sychterz C J, Yang A M, McAuley J P, Engh C A. Twodimensional versus three-dimensional radiographic measurements of polyethylene wear. Clin Orthop 1999, 365: 117–23
- Sychterz C J, Young A M, Engh C A. Effect of radiographic quality on computer-assisted head penetration measurements. Clin Orthop 2001, 386: 150–8
- Tannast M, Zheng G, Anderegg C, Burckhardt K, Langlotz F, Ganz R, Siebenrock K A. Tilt and rotation correction of acetabular version on pelvic radiographs. Clin Orthop 2005, 438: 182–90
- von Schewelov T, Onsten I, Markusson P, Carlsson A. Weight bearing radiographs are not necessary for measurement of polyethylene penetration in total hip prostheses: a radiostereometric study of 111 patients examined in weight-bearing and supine position. Acta Orthop 2006; 77: 104–8
- Wasielewski R C, Jacobs J J, Arthurs B, Rubash H E. The acetabular insert-metal backing interface. An additional source of polyethylene wear debris. J Arthroplasty 2005; 20: 914–22
- Yamaguchi M, Bauer T W, Hashimoto Y. Deformation of the acetabular polyethylene liner and the backside gap. J Arthroplasty 1999a; 14: 464–9
- Yamaguchi M, Hashimoto Y, Akisue T, Bauer T W. Polyethylene wear vector in vivo: A three-dimensional analysis using retrieved acetabular components and radiographs. J Orthop Res 1999b; 17: 695–702
Free access
Polyethylene acetabular wear in hip prostheses: Computer-simulated quantification of error caused by changes in pelvic orientation and direction of wear
Reprints and Corporate Permissions
Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?
To request a reprint or corporate permissions for this article, please click on the relevant link below:
Academic Permissions
Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?
Obtain permissions instantly via Rightslink by clicking on the button below:
If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.
Related research
People also read lists articles that other readers of this article have read.
Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.
Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.