1,239
Views
22
CrossRef citations to date
0
Altmetric
Original Articles

Mobile-bearing medial unicompartmental knee arthroplasty restores limb alignment comparable to that of the unaffected contralateral limb

, &
Pages 70-74 | Received 18 Jul 2016, Accepted 12 Sep 2016, Published online: 31 Oct 2016

  • Bellemans J, William C, Vandenneuker H, Victor J. The Chitranjan Ranawat award. Is neutral mechanical alignment unaffected for all patients? The concept of constitutional varus. Clin Orthop Relat Res 2012; 470 (1): 45–53.
  • Brouwer G M, van Tol A W, Bergink A P, Belo J N, Bernsen R M, Reijman M, Pols H A, Bierma-Zeinstra S M. Association between valgus and varus alignment and the development and progression of radiographic osteoarthritis of the knee. Arthritis Rheum 2007; 56(4): 1204–11.
  • Cool S, Victor J, De Baets T. Does a minimally invasive approach affect positioning of components in unicompartmental knee arthroplasty? Early results with survivorship analysis. Acta Orthop Belg 2006; 72(6): 709–15.
  • Dossett H G, Swartz G J, Estrada N A, LeFevre G W, Kwasman B G. Kinematically versus mechanically aligned total knee arthroplasty. Orthopedics 2012; 35(2): 160–69.
  • Eckhoff D G, Bach J M, Spitzer V M, Reinig K D, Bagur M M, Baldini T H, Flannery N M. Three-dimensional mechanics, kinematics, and morphology of the knee viewed in virtual reality. J Bone Joint Surg (Am) 2005; 87(Suppl2): 71–80.
  • Emerson R H, Higgins L L. Unicompartmental knee arthroplasty with the Oxford prosthesis in patients with medial compartment arthritis. J Bone Joint Surg (Am) 2008; 90(1): 118–22.
  • Faour-Martín O, Valverde-García J A, Martín-Ferrero M A, Vega-Castrillo A, de la Red Gallego M A, Suárez de Puga C C, Amigo-Liñares L. Oxford phase 3 unicondylar knee arthroplasty through a minimally invasive approach: Long-term results. Int Orthop 2013; 37(5): 833–38.
  • Howell S M, Hull M L. Kinematic alignment in total knee arthroplasty. In: Scott WN and Scuderi G,eds. Insall and Scott Surgery of the Knee. Fifth ed. Philadelphia, PA: Elsevier, 2012: 1255–68.
  • Howell S M, Kusnik K, Hull M L, Siston R A. Longitudinal shapes of the tibia and femur are unrelated and variable. Clin Orthop Relat Res 2010; 468(4): 1142–48.
  • Howell S M, Howell S J, Kuznik K T, Cohen J, Hull M L. Does a kinematically aligned total knee arthroplasty restore function without failure regardless of alignment category? Clin Orthop Relat Res 2013; 471(3): 1000–07.
  • Kellgren J H, Lawrence J S. Radiological assessment of osteo-arthrosis. Ann Rheum Dis 1957; 16(4): 494–502.
  • Kennedy W R, White R P. Unicompartmental arthroplasty of the knee. Postoperative alignment and its influence on overall results. Clin Orthop Relat Res 1987; (221): 278–85.
  • Kim S J, Bae J H, Lim H C. Factors affecting the postoperative limb alignment and clinical outcome after Oxford unicompartmental knee arthroplasty. J Arthroplasty 2012; 27(6): 1210–15.
  • Kozinn S C, Scott R. Unicondylar knee arthroplasty. J Bone Joint Surg (Am) 1989; 71 (1): 141–50.
  • Marx R G, Grimm P, Lillemoe K A, Robertson C M, Ayeni O R, Lyman S, Bogner E A, Pavlov H. Reliability of lower extremity alignment measurement using radiographs and PACS. Knee Surg Sports Traumatol Arthrosc 2011; 19(10): 1693–98.
  • Mullaji A B, Sharma A, Marawar S. Unicompartmental knee arthroplasty: functional recovery and radiographic results with a minimally invasive technique. J Arthroplasty 2007; 22(4Suppl1): 7–11.
  • Mullaji A B, Shetty G M, Kanna R. Postoperative limb alignment and its determinants after minimally invasive Oxford medial unicompartmental knee arthroplasty. J Arthroplasty 2011; 26(6): 919–25.
  • Nunley R M, Ellison B S, Zhu J, Ruh E L, Howell S M, Barrack R L. Do patient-specific guides improve coronal alignment in total knee arthroplasty? Clin Orthop Relat Res 2012; 470(3): 895–902.
  • Shetty G M, Mullaji A, Bhayde S, Nha K W, Oh H K. Factors contributing to inherent varus alignment of lower limb in unaffected Asian adults: Role of tibial plateau inclination. Knee 2014; 21(2): 544–48.
  • Skytta E T, Haapamaki V, Koivikko M, Huhtala H, Remes V. Reliability of the hip-to-ankle radiograph in determining the knee and implant alignment after total knee arthroplasty. Acta Orthop Belg 2011; 77(3): 329–35.
  • Victor J M, Bassens D, Bellemans J, Gürsu S, Dhollander A A, Verdonk P C. Constitutional varus does not affect joint line orientation in the coronal plane. Clin Orthop Relat Res 2014; 472(1): 98–104.