- Andersen M R, Winther N, Lind T, Schr Der H, Flivik G, Petersen M M. Monoblock versus modular polyethylene insert in uncemented total knee arthroplasty. Acta Orthop 2016; 87(6): 607–14.
- Astephen J L, Wilson D A, Dunbar M J, Deluzio K J. Preoperative gait patterns and BMI are associated with tibial component migration. Acta Orthop 2010 Aug; 81(4): 478–86.
- Bates D, Maechler M, Bolker B, Walker S. Fitting linear mixed-effects models using lme4. J Statistical Software 2015; 67(1): 1–48.
- Behery O A, Kearns S M, Rabinowitz J M, Levine B R. Cementless vs cemented tibial fixation in primary total knee arthroplasty. J Arthroplasty 2017; 32(5): 1510–5.
- Brown T E, Harper B L, Bjorgul K. Comparison of cemented and uncemented fixation in total knee arthroplasty. Orthopedics 2013; 36(5): 380–7.
- Carlsson A, Bjorkman A, Besjakov J, Onsten I. Cemented tibial component fixation performs better than cementless fixation: a randomized radiostereometric study comparing porous-coated, hydroxyapatite-coated and cemented tibial components over 5 years. Acta Orthop 2005; 76(3): 362–9.
- Cherian J, Banerjee S, Kapadia B, Jauregui J, Harwin S, Mont M. Cementless total knee arthroplasty: a review. J Knee Surg 2014; 27(03): 193–8.
- Dalury D F. Cementless total knee arthroplasty: current concepts review. Bone Joint J 2016; 98-B(7): 867–73.
- Drexler M, Dwyer T, Marmor M, Abolghasemian M, Sternheim A, Cameron H U. Cementless fixation in total knee arthroplasty: down the boulevard of broken dream—opposes. J Bone Joint Surg Br 2012; 94(11 Suppl A): 85–9.
- FDA. Class 2 Device Recall Persona Trabecular Metal Tibial Plate/Persona TM Tibia; 2015.
- Freeman M A, Tennant R. The scientific basis of cement versus cementless fixation. Clin Orthop Relat Res 1992; (276): 19.
- Fricka K B, Sritulanondha S, McAsey C J. To cement or not? Two-year results of a prospective, randomized study comparing cemented vs. cementless total knee arthroplasty (TKA). J Arthroplasty 2015; 30(9 Suppl): 55–8.
- Henricson A, Nilsson K G. Trabecular metal tibial knee component still stable at 10 years. Acta Orthop 2016 Jul 27; 87(5): 504–10.
- Hilding M B, Yuan X, Ryd L. The stability of three different cementless tibial components: a randomized radiostereometric study in 45 knee arthroplasty patients. Acta Orthop Scand 1995; 66(1): 21.
- Malchau H. Introducing new technology: a stepwise algorithm. Spine 2000; 25(3): 285.
- Molt M, Toksvig-Larsen S. Peri-Apatite™ enhances prosthetic fixation in TKA: a prospective randomised RSA study. J Arthritis 2014; 03(03): 134.
- Mont M, Pivec R, Issa K, Kapadia B, Maheshwari A, Harwin S. Long-term implant survivorship of cementless total knee arthroplasty: a systematic review of the literature and meta-analysis. J Knee Surg 2014; 27(05): 369–76.
- Nakama G Y, Peccin M S, Almeida G J, Lira Neto Ode A, Queiroz A A, Navarro R D. Cemented, cementless or hybrid fixation options in total knee arthroplasty for osteoarthritis and other non-traumatic diseases. Cochrane DB Syst Rev 2012; 10: CD006193.
- Nelissen R G, Pijls B G, Karrholm J, Malchau H, Nieuwenhuijse M J, Valstar E R. RSA and registries: the quest for phased introduction of new implants. J Bone Joint Surg Am 2011; 93 (Suppl 3): 62–5.
- Nelissen R, Kaptein B, Veeger D. Edward Valstar (1970–2017). Acta Orthop 2017; 88(6): 701–2.
- Nilsson K G, Karrholm J, Ekelund L, Magnusson P. Evaluation of micromotion in cemented vs uncemented knee arthroplasty in osteoarthrosis and rheumatoid arthritis: randomized study using roentgen stereophotogrammetric analysis. J Arthroplasty 1991; 6(3): 265.
- Nilsson K G, Karrholm J, Carlsson L, Dalen T. Hydroxyapatite coating versus cemented fixation of the tibial component in total knee arthroplasty: prospective randomized comparison of hydroxyapatite-coated and cemented tibial components with 5-year follow-up using radiostereometry. J Arthroplasty 1999; 14(1): 9.
- Nilsson K G, Henricson A, Norgren B, Dalen T. Uncemented HA-coated implant is the optimum fixation for TKA in the young patient. Clin Orthop Relat Res 2006; 448: 129.
- Onsten I, Nordqvist A, Carlsson A S, Besjakov J, Shott S. Hydroxyapatite augmentation of the porous coating improves fixation of tibial components: a randomised RSA study in 116 patients. J Bone Joint Surg Br 1998; 80(3): 417.
- Pijls B G. Evidence based introduction of orthopaedic implants: RSA, implant quality and patient safety. Doctoral Thesis, Leiden University 2014. p 1–194.
- Pijls B G, Valstar E R, Kaptein B L, Fiocco M, Nelissen R G. The beneficial effect of hydroxyapatite lasts: a randomized radiostereometric trial comparing hydroxyapatite-coated, uncoated, and cemented tibial components for up to 16 years. Acta Orthop 2012a; 83(2): 135-41.
- Pijls B G, Valstar E R, Nouta K A, Plevier J W, Fiocco M, Middeldorp S, et al. Early migration of tibial components is associated with late revision: a systematic review and meta-analysis of 21,000 knee arthroplasties. Acta Orthop 2012b; 83(6): 614–24.
- Pijls B G, Plevier J W M, Nelissen R. RSA migration of total knee replacements: a systematic review and meta-analysis. Acta Orthop 2018; 89(3): 320–8.
- R Core Team. R: A language and environment for statistical computing. Vienna, Austria: R Foundation for Statistical Computing; 2015.
- Regner L, Carlsson L, Karrholm J, Herberts P. Tibial component fixation in porous- and hydroxyapatite-coated total knee arthroplasty: a radiostereometric evaluation of migration and inducible displacement after 5 years. J Arthroplasty 2000; 15(6): 681.
- Ryd L, Albrektsson B E, Carlsson L, Dansgard F, Herberts P, Lindstrand A, et al. Roentgen stereophotogrammetric analysis as a predictor of mechanical loosening of knee prostheses. J Bone Joint Surg Br 1995; 77(3): 377.
- Selvik G. Roentgen stereophotogrammetry: a method for the study of the kinematics of the skeletal system. Acta Orthop Scand Suppl 1989; 232: 1.
- Stilling M, Madsen F, Odgaard A, Romer L, Andersen N T, Rahbek O, et al. Superior fixation of pegged trabecular metal over screw-fixed pegged porous titanium fiber mesh: a randomized clinical RSA study on cementless tibial components. Acta Orthop 2011; 82(2): 177–86.
- Toksvig-Larsen S, Jorn L P, Ryd L, Lindstrand A. Hydroxyapatite-enhanced tibial prosthetic fixation. Clin Orthop Relat Res 2000(370): 192.
- Valstar E R, Gill R, Ryd L, Flivik G, Börlin N, Kärrholm J. Guidelines for standardization of radiostereometry (RSA) of implants. Acta Orthop 2005; 76(4): 563–72.
- van Hamersveld K T, Marang-van de Mheen P J, Tsonaka R, Valstar E R, Toksvig-Larsen S. Fixation and clinical outcome of uncemented peri-apatite-coated versus cemented total knee arthroplasty: five-year follow-up of a randomised controlled trial using radiostereometric analysis (RSA). Bone Joint J 2017; 99-B(11): 1467–76.
- Wilson D A, Richardson G, Hennigar A W, Dunbar M J. Continued stabilization of trabecular metal tibial monoblock total knee arthroplasty components at 5 years measured with radiostereometric analysis. Acta Orthop 2012; 83(1): 36–40.
- Zandee van Rilland E D, Varcadipane J C, Geling O, Murai Kuba M, Nakasone C K. A minimum 2-year follow-up using modular trabecular metal tibial components in total knee arthroplasty. Recons Rev 2015; 5(3): 23–8.
Acta Orthopaedica
Volume 90, 2019 - Issue 2
Open access
1,577
Views
26
CrossRef citations to date
0
Altmetric
Articles
Equivalent 2-year stabilization of uncemented tibial component migration despite higher early migration compared with cemented fixation: an RSA study on 360 total knee arthroplasties
Elise K LaendeSchool of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada;; ;Division of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada;; Correspondence[email protected]
, Janie L Astephen WilsonSchool of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada;; ;Department of Surgery, Dalhousie University, Halifax, Nova Scotia, Canada;;
, Joanna Mills FlemmingDepartment of Mathematics and Statistics, Dalhousie University, Halifax, Nova Scotia, Canada;;
, Edward R ValstarDepartment of Orthopedics, Leiden University Medical Center, Leiden, The Netherlands
, C Glen RichardsonDivision of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada;;
& Michael J DunbarSchool of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada;; ;Division of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada;;
Pages 172-178
|
Published online: 23 Jan 2019
Related research
People also read lists articles that other readers of this article have read.
Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.
Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.