- Donahue G S, Galea V P, Laaksonen I, Connelly J W, Muratoglu O, Malchau H. Establishing thresholds for metal ion levels in patients with bilateral articular surface replacement hip arthroplasty. HIP Int 2019; 29(5): 475–80.
- EFORT. European Federation of National Associations of Orthopaedics and Traumatology (EFORT), E. H. S. E., Consensus statement “Current Evidence on the Management of Metal-on-Metal Bearings”, April 16, 2012.
- Finnish Arthroplasty Register. https://www.thl.fi/far/.
- Finnish Arthroplasty Society. Recommendation for the use and follow-up of patients with metal-on-metal (MoM) hip arthroplasty; 2015.
- Hannemann F, Hartmann A, Schmitt J, Lützner J, Seidler A, Campbell P, Delaunay C P, Drexler H, Ettema H B, García-Cimbrelo E, Huberti H, Knahr K, Kunze J, Langton D J, Lauer W, Learmonth I, Lohmann C H, Morlock M, Wimmer M A, Zagra L, Günther K P. European multidisciplinary consensus statement on the use and monitoring of metal-on-metal bearings for total hip replacement and hip resurfacing. Orthop Traumatol Surg Res 2013; 99(3): 263–71.
- Hart A J, Sabah S A, Sampson B, Skinner J A, Powell J J, Palla L, Pajamäki K J J, Puolakka T, Reito A, Eskelinen A. Surveillance of patients with metal-on-metal hip resurfacing and total hip prostheses: a prospective cohort study to investigate the relationship between blood metal ion levels and implant failure. J Bone Joint Surg Am 2014; 96(13): 1091–9.
- Health Canada. “Metal-on-metal hip implants—information for orthopaedic surgeons regarding patient management following surgery—for health professionals”; May 9, 2012.
- Kasparek M F, Renner L, Faschingbauer M, Waldstein W, Weber M, Boettner F. Predictive factors for metal ion levels in metal-on-metal total hip arthroplasty. Arch Orthop Trauma Surg 2018; 138(2): 281–6.
- Mäntymäki H, Lankinen P, Vahlberg T, Reito A, Eskelinen A, Mäkelä K. Repeated cobalt and chromium ion measurements in patients with large-diameter head metal-on-metal ReCap-M2A-Magnum total hip replacement. Acta Orthop 2019; 90(3): 243–8.
- Matharu G S, Mellon S J, Murray D W, Pandit H G. Follow-up of metal-on-metal hip arthroplasty patients is currently not evidence based or cost effective. J Arthroplasty 2015; 30(8): 1317–23.
- Matharu G S, Berryman F, Brash L, Pynsent P B, Treacy R B C, Dunlop D J. The effectiveness of blood metal ions in identifying patients with unilateral Birmingham hip resurfacing and Corail-Pinnacle metal-on-metal hip implants at risk of adverse reactions to metal debris. J Bone Joint Surg Am 2016; 98(8): 617–26.
- Matharu G S, Berryman F, Judge A, Reito A, McConnell J, Lainiala O, Young S, Eskelinen A, Pandit H G, Murray D W. Blood metal ion thresholds to identify patients with metal-on-metal hip implants at risk of adverse reactions to metal debris: An external multicenter validation study of Birmingham hip resurfacing and Corail-Pinnacle implants. J Bone Joint Surg Am 2017; 99(18): 1532–9.
- MHRA. Medical Device Alert: All metal-on-metal (MoM) hip replacements: updated advice for follow-up of patients; 2017.
- Reito A, Moilanen T, Puolakka T, Pajamäki J, Eskelinen A. Repeated metal ion measurements in patients with high risk metal-on-metal hip replacement. Int Orthop 2014; 38(7): 1353–61.
- Reito A, Lainiala O, Nieminen J, Eskelinen A. Repeated metal ion measurement in patients with bilateral metal on metal (ASRTM) hip replacements. Orthop Traumatol Surg Res 2016; 102(2): 167–73.
- Seppanen M, Laaksonen I, Pulkkinen P, Eskelinen A, Puhto A P, Kettunen J, Leskinen J, Manninen M, Makela K. High revision rate for large-head metal-on-metal THA at a mean of 7.1 years: a registry study. Clin Orthop Relat Res 2018; 476(6): 1223–30.
- Sidaginamale R P, Joyce T J, Lord J K, Jefferson R, Blain P G, Nargol A V F, Langton D J. Blood metal ion testing is an effective screening tool to identify poorly performing metal-on-metal bearing surfaces. Bone Joint Res 2013; 2(5): 84–95.
- De Smet K, De Haan R, Calistri A, Campbell P A, Ebramzadeh E, Pattyn C, Gill H S. Metal ion measurement as a diagnostic tool to identify problems with metal-on-metal hip resurfacing. J Bone Joint Surg Am 2008; 90(4): 202–8.
- Van Der Straeten C, Grammatopoulos G, Gill H S, Calistri A, Campbell P, De Smet K A. The 2012 Otto Aufranc Award: The interpretation of metal ion levels in unilateral and bilateral hip resurfacing. Clin Orthop Relat Res 2013; 471(2): 377–85.
- US Food and Drug Administration (FDA). Medical devices: Metal-on-metal hip implants, information for orthopaedic surgeons; 2019.
Acta Orthopaedica
Volume 91, 2020 - Issue 4
Open access
1,470
Views
2
CrossRef citations to date
0
Altmetric
Articles
Repeated cobalt and chromium ion measurements in patients with bilateral large-diameter head metal-on-metal ReCap-M2A-Magnum total hip replacement
Sakari PietiläinenDepartment of Orthopaedics and Traumatology, Turku University Hospital and University of Turku; Correspondence[email protected]
, Heikki MäntymäkiDepartment of Orthopaedics, Tampere University Hospital and University of Turku;
, Tero VahlbergDepartment of Biostatistics, University of Turku;
, Aleksi ReitoCoxa Hospital for Joint Replacement, Tampere, Finland
, Antti EskelinenCoxa Hospital for Joint Replacement, Tampere, Finland
, Petteri LankinenDepartment of Orthopaedics and Traumatology, Turku University Hospital and University of Turku;
& Keijo MäkeläDepartment of Orthopaedics and Traumatology, Turku University Hospital and University of Turku;
show all
Pages 378-382
|
Published online: 14 Apr 2020
Related research
People also read lists articles that other readers of this article have read.
Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.
Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.