References
- Kennett , T. J. , Prestwich , W. V. and Tsai , J. S. 1986 . “The 14N(n,γ)15N reaction as both an intensity and energy standard” . Nucl. Instr. and Meth., A , 249 : 366 – 378 .
- Jurney , E. T. , Starner , J. W. , Lynn , J. E. and Raman , S. 1997 . “Thermalneutron capture by 14N” . Phys. Rev., C , 56 : 118 – 134 .
- Raman , S. , Yonezawa , C. , Matsue , H. , Iimura , H. and Shinohara , N. 2000 . “Efficiency calibration of a Ge detector in the 0.1-11.0MeV region” . Nucl. Instr. and Meth., A , 454 : 389 – 402 .
- Takayama , H. , Kasaishi , M. , Tojo , A. , Hayashi , H. , Miyazaki , I. , Shimizu , T. , Shibata , M. , Kawade , K. , Taniguchi , A. , Sakane , H. and Harada , H. 2005 . “Precise measurement of prompt _-ray in the 14N(n,γ)15N reaction” . In Proc. 2004 Symp. on Nuclear Data INDC(JPN)-195/U Edited by: Tahara , Y. and Fukahori , T. 222 – 227 . Tokai , , Japan : JAERI . edited by (, 2005
- Belgya , T. 2006 . “Improved accuracy of γ-ray intensities from basic principles for the calibration reaction 14N(n, γ)15N” . Phys. Rev., C , 74 : 024603 – 1 . 024603–8
- Molná , G. L. , Révay , Zs. and Belgya , T. 2004 . “Accurate absolute intensities for the 35Cl(n, γ) reaction gamma-ray standard” . Nucl. Instr. and Meth., B , 213 : 32 – 35 .
- Baglin , C. M. , Browne , E. , Norman , E. B. , Molnár , G. L. , Blgya , T. , Revay , Zs. and Szelecsényi , F. 2002 . “66Ga: a standard for high-energy calibration of Ge detectors” . Nucl. Instr. and Meth., A , 481 : 365 – 377 .
- Sakane , H. , Obayashi , H. , Tojo , A. , Shibata , M. , Kawade , K. and Taniguchi , A. 2005 . “Preparation of a liquid nitrogen target for measurement of γ-rays in the 14N(n, γ)15N reaction as an intensity standard in energy regions up to 11 MeV” . Appl. Radiat. Isot. , 63 : 131 – 135 .
- Nakamura , S. , Harada , H. , Takayama , H. and Kawade , K. 2003 . “The development of melamine-D for the precise measurement of detection efficiencies of high energy γ-rays” . In Proc. 2002 Symp. on Nuclear Data INDC(JPN)-191/U Edited by: Ohsawa , T. and Fukahori , T. 237 – 240 . Tokai , , Japan : JAERI . edited by (, 2003
- Kasaishi , M. , Tojo , A. , Furuta , M. , Takayama , H. , Miyazaki , I. , Shimizu , T. , Shibata , M. , Kawade , K. and Taniguchi , A. 2005 . “Calculation of an HPGe detector peak efficiency curve up to 11MeV with EGS4 and GEANT4” . In Proc. 2004 Symp. on Nuclear Data INDC(JPN)-195/U Edited by: Tahara , Y. and Fukahori , T. 216 – 221 . Tokai , , Japan : JAERI . edited by (, 2005
- Akiyoshi , T. , Ebisawa , T. , Kawai , T. , Yoshida , F. , Ono , M. , Tasaki , S. , Mitani , S. , Kobayashi , T. and Okamoto , S. 1992 . “Development of a Supermirror Neutron Guide Tube” . J. Nucl. Sci. Technol. , 29 : 939 – 946 .
- Kawade , K. , Ezuka , M. , Yamamoto , H. , Sugioka , K. and Katoh , T. 1981 . “Efficiency calibration of a Ge(Li) detector at short sourceto-detector distance” . Nucl. Instr. and Meth. , 190 : 101 – 106 .
- Yamada , S. 2000 . “VIPF (Visual peak fitting)” . Technical Reports of the Research Reactor Institute, Kyoto University , 430 : 40 KURRI-TR-
- Molnár , G. L. , Révay , Zs. and Belgya , T. 2002 . “Wide energy range efficiency calibration method for Ge detectors” . Nucl. Instr. and Meth., A , 489 : 140 – 159 .
- Helmer , R. G. , Hardy , J. C. , Iacob , V. E. , Sanchez-Vega , M. , Neilson , R. G. and Nelson , J. 2003 . “The use of Monte Carlo calculations in the determination of a Ge detector efficiency curve” . Nucl.Instr. and Meth., A , 511 : 360 – 381 .
- Ludington , M. A. and Helmer , R. G. 2000 . “High accuracy measurements and Monte Carlo calculations of the relative efficiency curve of an HPGe detector from 433 to 2754 keV” . Nucl. Instr. and Meth., A , 446 : 506 – 521 .
- Nelson , W. R. , Hirayama , H. and Rogers , D. W. O. 1985 . “EGS4 code system” . Reports of Stanford Linear Accelerator Center, SLAC , 265 -
- Agostinelli , S. , Allison , J. Amako , K. 2003 . “GEANT4-a simulation toolkit” . Nucl. Instr. and Meth., A , 506 : 250 – 303 .
- Belgya , T. 2005 . “Spline and polynomial models of the efficiency function for Ge gamma-ray detectors in a wide energy range” . J. Radioanal. Nucl. Chem. , 265 : 175 – 179 .
- Miyazaki , I. , Tojo , A. , Furuta , M. , Shibata , M. , Taniguchi , A. and Kawade , K. “Checking the reliability of prompt γ-ray emission probabilities for the measurement of neutron capture cross sections,” in preparation for submission to . J. Nucl. Sci.Technol. ,