References
- Ameri G, Baxter JSH, Bainbridge D, Peters TM, Chen ECS. 2018. Mixed reality ultrasound guidance system: a case study in system development and a cautionary tale. Int J Comput Assist Radiol Surg. 13(4):495–505.
- Chao A, Lai C-H, Chan K-C, Yeh -C-C, Yeh H-M, Fan S-Z, Sun W-Z. 2014. Performance of central venous catheterization by medical students: a retrospective study of students’ logbooks. BMC Med Educ. 14(1):168. doi:10.1186/1472-6920-14-168.
- Chen ECS, Lasso A, Fichtinger G. 2020. External tracking devices and tracked tool calibration. In: S. Kevin Z, Daniel R, Gabor F, editors. Handbook of medical image computing and computer assisted intervention. Elsevier; p. 777–794.
- Chen ECS, Peters TMM. 2016. Guided ultrasound calibration: where, how, and how many calibration fiducials. Int J Comput Assist Radiol Surg. 11(6):889–898. doi:10.1007/s11548-016-1390-7.
- Girardeau-Montaut D. 2011. Cloudcompare-open source project. OpenSource Project.
- Gordon AC, Saliken JC, Johns D, Owen R, Gray RR. 1998. Us-guided puncture of the internal jugular vein: complications and anatomic considerations. J Vasc Interventional Radiol. 9(2):333–338. doi:10.1016/S1051-0443(98)70277-5.
- Groves L, Li N, Peters TM, Chen ECS. 2019. Towards a mixed-reality first person point of view needle navigation system. In: Shen D, Liu T, Peters TM, Staib LH, Essert C, Zhou S, Yap P-T, Khan A, editors. Medical image computing and computer assisted intervention – MICCAI 2019. Cham: Springer International Publishing; p. 245–253.
- Groves LA, VanBerlo B, Veinberg N, Alboog A, Peters TM, Chen ECS. 2020. Automatic segmentation of the carotid artery and internal jugular vein from 2d ultrasound images for 3d vascular reconstruction. Int J Comput Assist Radiol Surg. doi:10.1007/s11548-020-02248-2
- Hameeteman M, Bode AS, Peppelenbosch AG, Van der Sande FM, Tordoir JHM. 2010. Ultrasound-guided central venous catheter placement by surgical trainees: A safe procedure? J Vasc Access. 11(4):288–292. doi:10.5301/JVA.2010.2372.
- Horn BKP. 1987. Closed-form solution of absolute orientation using unit quaternions. J Opt Soc Am A. 4(4):629–642. doi:10.1364/JOSAA.4.000629.
- Izzo R, Steinman D, Manini S, Antiga L. 2018. The vascular modeling toolkit: a python library for the analysis of tubular structures in medical images. J Open Source Software. 3(25):745.
- Kornbau C, Lee KC, Hughes GD, Firstenberg MS. 2015. Central line complications. Int J Crit Illn Inj Sci. 5(3):170. doi:10.4103/2229-5151.164940.
- Raad I. 1998. Intravascular-catheter-related infections. Lancet (London, England). 351(9106):893–898. doi:10.1016/S0140-6736(97)10006-X.
- Saugel B, Scheeren TWL, Teboul J-L. 2017. Ultrasound-guided central venous catheter placement: a structured review and recommendations for clinical practice. Crit Care. 21(1):225. doi:10.1186/s13054-017-1814-y.
- Soni NJ, Reyes LF, Keyt H, Arango A, Gelfond JA, Peters JI, Levine SM, Adams SG, Restrepo MI. 2016. Use of ultrasound guidance for central venous catheterization: a national survey of interventionists and hospitalists. J Crit Care. 36:277–283. doi:10.1016/j.jcrc.2016.07.014.
- Surry KJM, Austin HJB, Fenster A, Peters TM. 2004. Poly(vinyl alcohol) cryogel phantoms for use in ultrasound and MR imaging. Phys Med Biol. 49(24):5529–5546. doi:10.1088/0031-9155/49/24/009.
- Turba UC, Uflacker R, Hannegan C, Selby JB. 2005. Anatomic relationship of the internaljugular vein and the common carotid artery applied to percutaneous transjugular procedures. Cardiovasc Intervent Radiol. 28(3):303–306. doi:10.1007/s00270-004-0039-z.