References
- Strazielle N, Ghersi-Egea JF. Physiology of blood-brain interfaces in relation to brain disposition of small compounds and macromolecules. Mol Pharm. 2013;10(5):20–34. DOI:https://doi.org/10.1021/mp300518e.
- Johanson CE, Keep RF. Blending established and new perspectives on choroid plexus-CSF dynamics. In: Praetorius J, Blazer-Yost B, Damkier H, editors. Role of the choroid plexus in health and disease. New York (NY): Springer; 2020. p. 35–81.
- Oreskovic D, Rados M, Klarica M. Role of the choroid plexus in cerebrospinal fluid hydrodynamics. Neuroscience. 2017;354:69–87. DOI:https://doi.org/10.1016/j.neuroscience.2017.04.025.
- Cornford EM, Varesi JB, Hyman S, Damian RT, Raleigh MJ. Mitochondrial content of choroid plexus epithelium. Exp Brain Res. 1997;116(3):399–405. DOI:https://doi.org/10.1007/PL00005768.
- Baehr C, Reichel V, Fricker G. Choroid plexus epithelial monolayers- a cell culture model from porcine brain. Cerebrospinal Fluid Res. 2006;3(1):13. DOI:https://doi.org/10.1186/1743-8454-3-13.
- Rosenthal R, Gunzel D, Krug SM, Schulzke JD, Frommm M, Yu AS. Claudin-2-mediated cation and water transport share a common pore. Acta Physiol. 2017;219(2):521–536. DOI:https://doi.org/10.1111/apha.12742.
- Zeuthen T, MacAulay N. Transport of water against its concentration gradient: fact or fiction? WIREs Memtr Transp Signal. 2012;1(4):373–381. DOI:https://doi.org/10.1002/wmts.54.
- Damkier H, Brown P, Praetorius J. Epithelial pathways in choroid plexus electrolyte transport. Physiology. 2010;25(4):239–249. DOI:https://doi.org/10.1152/physiol.00011.2010.
- MacAulay N. Molecular mechanisms of water transport. Nat Rev Neurosci. 2021;22(6):326–344. DOI:https://doi.org/10.1038/s41583-021-00454-8.
- Brindle K. Watching tumours gasp and die with MRI: the promise of hyperpolarised 13C-MR spectroscopic imaging. Br J Radiol. 2012;85(1014):697–708. DOI:https://doi.org/10.1259/bjr/81120511.
- Jochumsen MR, Sörensen J, Pedersen BG, Nyengaard JR, Krag SR, Frøkiær J, Borre M, Bouchelouche K, Tolbod LP. Tumour blood flow for prediction of human prostate cancer aggressiveness: a study with Rubidium-82 PET, MRI and Na+/K+-ATPase-density. Eur J Nucl Med Mol Imaging. 2021;48(2);532–542. DOI:https://doi.org/10.1007/s00259-00020-04998-00252.
- Wang Q, Li SB, Zhao YY, Dai DN, Du H, Lin YZ, Ye JC, Zhao J, Xiao W, Mei Y, et al. Identification of a sodium pump Na+/K+ ATPase α1-targeted peptide for PET imaging of breast cancer. J Control Release. 2018;281:178–188. DOI:https://doi.org/10.1016/j.jconrel.2018.05.019.
- Li X, Mangia S, Lee J-H, Bai R, Springer CS. NMR shutter-speed elucidates apparent population inversion of 1H2O signals due to active transmembrane water cycling. Magn Reson Med. 2019;82(1):411–424. DOI:https://doi.org/10.1002/mrm.27725.
- Rooney WD, Li X, Sammi MK, Bourdette DN, Neuwelt EA, Springer CS. Mapping human brain capillary water lifetime: high-resolution metabolic neuroimaging. NMR Biomed. 2015;28(6):607–623. DOI:https://doi.org/10.1002/nbm.3294.
- Butterfield DA, Boyd-Kimball D. Mitochondrial oxidative and nitrosative stress and Alzheimer disease. Antioxidants. 2020;9(9):818. DOI:https://doi.org/10.3390/antiox9090818.
- Zweig JA, Caruso M, Brandes MS, Gray NE. Loss of NRF2 leads to impaired mitochondrial function, decreased synaptic density and exacerbated age-related cognitive deficits. Exp Gerontol. 2020;131:110767. DOI:https://doi.org/10.1016/j.exger.2019.110767.
- Anderson AE, Diaz-Santos M, Frei S, Dang BH, Kaur P, Lyden P, Buxton R, Douglas PK, Bilder RM, Esfandiari M, et al. Hemodynamic latency is associated with reduced intelligence across the lifespan: an fMRI DCM study of aging, cerebrovascular integrity, and cognitive ability. Brain Struct Funct. 2020a;225(6):1705–1717. DOI:https://doi.org/10.1007/s00429-020-02083-w.
- Iadecola C. The neurovascular unit coming of age: a journey through neurovascular coupling in health and disease. Neuron. 2017;96(1):17–42. DOI:https://doi.org/10.1016/j.neuron.2017.07.030.
- Nation DA, Sweeney MD, Montagne A, Sagare AP, D’Orazio LM, Pachicano M, Sepehrband F, Nelson AR, Buennagel DP, Harrington MG, et al. Blood-brain barrier breakdown is an early biomarker of human cognitive dysfunction. Nat Med. 2019;25(2):270–276. DOI:https://doi.org/10.1038/s41591-018-0297-y.
- Preston JE. Ageing choroid plexus-cerebrospinal fluid system. Microsc Res Tech. 2001;52(1):31–37. DOI:https://doi.org/10.1002/1097-0029(20010101)52:1<31::AID-JEMT5>3.0.CO;2-T.
- Chen RL, Kassem NA, Redzic ZB, Chen CPC, Segal MB, Preston JE. Age-related changes in choroid plexus and blood-cerebrospinal fluid barrier function in sheep. Exp Gerontol. 2009;44(4):289–296. DOI:https://doi.org/10.1016/j.exger.2008.12.004.
- Masseguin C, LePanse S, Corman B, Verbavatz JM, Gabrion J. Aging affects choroidal proteins involved in CSF production in Sprague-Dawley rats. Neurobiol Aging. 2005;26(6):917–927. DOI:https://doi.org/10.1016/j.neurobiolaging.2004.07.013.
- Tofts PS, Brix G, Buckley DL, Evelhoch JL, Henderson E, Knopp MV, Larsson HB, Lee TY, Mayr NA, Parker GJM, et al. Estimating kinetic parameters from dynamic contrast-enhanced T(1)-weighted MRI of a diffusable tracer: standardized quantities and symbols. J Magn Reson Imaging. 1999;10(3):223–232. DOI:https://doi.org/10.1002/(SICI)1522-2586(199909)10:3<223::AID-JMRI2>3.0.CO;2-S.
- Heye AK, Culling RD, Valdés Hernández MC, Thrippleton MJ, Wardlaw JM. Assessment of blood–brain barrier disruption using dynamic contrast-enhanced MRI. A systematic review. Neuroimage: Clinical. 2014;6:262–274. DOI:https://doi.org/10.1016/j.nicl.2014.09.002.
- Jackson A, Buckley DL, Parker GJM. Dynamic contrast-enhanced magnetic resonance imaging in oncology. Berlin, Germany: Springer-Verlag; 2005.
- Landis CS, Li X, Telang FW, Coderre JA, Micca PL, Rooney WD, Latour LL, Vétek G, Springer CS, Jr. Determination of the MRI contrast agent concentration time course in vivo following bolus injection: effect of equilibrium transcytolemmal water exchange. Magn Reson Med. 2000;44:563–574.
- Li X, Rooney WD, Springer CS. A unified MRI pharmacokinetic theory: intravascular and extracellular contrast reagents. Magn Reson Med. 2005b;54(6):1351–1359. DOI:https://doi.org/10.1002/mrm.20684.
- Yankeelov TE, Rooney WD, Li X, Springer CS. Variation of the relaxographic “shutter-speed” for transcytolemmal water exchange affects the CR bolus-tracking curve shape. Magn Reson Med. 2003;50(6):1151–1169. DOI:https://doi.org/10.1002/mrm.10624.
- Allen MJ, Meade TJ. Synthesis and visualization of a membrane-permeable MRI contrast agent. J Biol Inorg Chem. 2003;8(7):746–750. DOI:https://doi.org/10.1007/s00775-003-0475-2.
- Caravan P, Ellison JJ, McMurry TJ, Lauffer RB. Gadolinium(III) chelates as MRI contrast agents: structure, dynamics, and applications. Chem Rev. 1999;99:2293–2352. DOI:https://doi.org/10.1021/cr980440x.
- Huang W, Li X, Morris EA, Tudorica LA, Seshan VE, Rooney WR, Tagge I, Wang Y, Xu J, Springer CS, et al. The magnetic resonance shutter speed discriminates vascular properties of malignant and benign breast tumors in vivo. Proc Nat Acad Sci. 2008;105(46):17943–17948. DOI:https://doi.org/10.1073/pnas.0711226105.
- Li X, Priest RA, Woodward WJ, Siddiqui F, Beer TM, Garzotto MG, Rooney WD, Springer CS. Cell membrane water exchange effects in prostate DCE-MRI. J Magn Reson. 2012;218:77–85. DOI:https://doi.org/10.1016/j.jmr.2012.03.019.
- Rooney WD, Yankeelov TE, Coyle PK, Telang FW, Springer CS. Quantitative measurement of contrast reagent blood-brain barrier permeability in multiple sclerosis. Proc Int Soc Magn Reson Med. 2003;11:276.
- Yankeelov TE, Rooney WD, Huang W, Dyke JP, Li X, Tudorica A, Lee JH, Koutcher JA, Springer CS. Evidence for shutter-speed variation in CR bolus-tracking studies of human pathology. NMR Biomed. 2005;18(3):173–185. DOI:https://doi.org/10.1002/nbm.938.
- Li X, Huang W, Morris EA, Tudorica LA, Seshan VE, Rooney WD, Tagge I, Wang Y, Xu J, Springer CS, et al. Dynamic NMR effects in breast cancer dynamic-contrast-enhanced MRI. Proc Nat Acad Sci. 2008;105(46):17937–17942. DOI:https://doi.org/10.1073/pnas.0804224105.
- Folstein MF, Folstein SE, McHugh PR. “Mini-mental state”: a practical method for grading the cognitive state of patients for the clinician. J Psychiatr Res. 1975;12(3):189–198. DOI:https://doi.org/10.1016/0022-3956(75)90026-6.
- Abikoff H, Alvir J, Hong G, Sukoff R, Orazio J, Solomon S, Saravay S. Logical memory subtest of the Wechsler Memory Scale: age and education norms and alternate-form reliability of two scoring systems. J Clin Exp Neuropsychol. 1987;9(4):435–448. DOI:https://doi.org/10.1080/01688638708405063.
- Morris JC, Heyman A, Mohs RC, Hughes JP, Van Belle G, Fillenbaum G, Mellits ED, Clark C. The Consortium to Establish a Registry for Alzheimer’s Disease (CXERAD). Part I. Clinical and neuropsychological assessment of Alzheimer’s disease. Neurology. 1989;39(9):1159–1165. DOI:https://doi.org/10.1212/WNL.39.9.1159.
- Bowie CR, Harvey PD. Administration and interpretation of the Trail Making Test. Nature Protocols. 2006;1(5):2277–2281. DOI:https://doi.org/10.1038/nprot.2006.390.
- Smith A. Symbol Digits Modalities Test (SDMT), Symbol Digits Modalities Test (SDMT) Manual. Los Angeles (CA): Western Psychological Services; 1982.
- Lezak MD. Neuropsychological Assessment. NY: Oxford University Press; 1995.
- Malek-Ahmadi M, Small BJ, Raj A. The diagnostic value of Controlled Oral Word Association Test-FAS and category fluency in single-domain amnestic mild cognitive impairment. Dement Geriatr Cogn Disord. 2012;32(4):235–240. DOI:https://doi.org/10.1159/000334525.
- O’Bryant SE, Humphreys JD, Smith GE, Ivnik RJ, Graff-Radford NR, Petersen RC, Lucas JA. Detecting Dementia with the Mini-Mental State Examination (MMSE) in Highly Educated Individuals. Arch Neurol. 2008;65(7):963–967. DOI:https://doi.org/10.1001/archneur.65.7.963.
- Li X, Huang W, Rooney WD. Signal-to-noise ratio, contrast-to-noise ratio and pharmacokinetic modeling considerations in dynamic contrast-enhanced magnetic resonance imaging. Magn Reson Imag. 2012;30(9):1313–1322. DOI:https://doi.org/10.1016/j.mri.2012.05.005.
- Dietrich O, Raya JG, Reeder SB, Reiser MF, Schoenberg SO. Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters. J Magn Reson Imaging. 2007;26(2):375–385. DOI:https://doi.org/10.1002/jmri.20969.
- Berlow YA, Vingara LK, Sammi MK, McMahon LE, Tagge I, Maloney B, Grinstead JW, Rooney WD. Unified segmentation at 7T. Proc Int Soc Magn Reson Med. 2014;22:4911.
- Jenkinson M, Beckmann CF, Behrens TE, Woolrich MW, Smith SM. FSL. Neuroimage. 2012;62(2):782–790. DOI:https://doi.org/10.1016/j.neuroimage.2011.09.015.
- Smith SM, Jenkinson M, Woolrich MW, Beckmann CF, Behrens T, Johansen-Berg H, Bannister PR, De Luca M, Drobnjak I, Flitney DE, et al. Advances in functional and structural MR image analysis and implementation as FSL. Neuroimage. 2004;23:S208–S219. DOI:https://doi.org/10.1016/j.neuroimage.2004.07.051.
- Markel M, Leupold J. Gradient echo imaging. J Magn Reson Imaging. 2012;35(6):1274–1289. DOI:https://doi.org/10.1002/jmri.23638.
- Deichmann R, Haase A. Quantification of T1 values by SNAPSHOT-FLASH NMR Imaging. J Magn Reson. 1992;96:608–612. DOI:https://doi.org/10.1002/mrm.1097.
- Scelsi CL, Rahim TA, Morris JA, Kramer GJ, Gilbert BC, Forseen SE. The lateral ventricles: a detailed review of anatomy, development, and anatomic variations. Amer J Neurorad. 2020;41(4):566–572. DOI:https://doi.org/10.3174/ajnr.A6456.
- Noebauer-Huhmann IM, Kraff O, Juras V, Szomolanyi P, Maderwald S, Mlynarik V, Thyesohn JM, Ladd SC, Trattnig S. MR contrast media at 7T- preliminary study on relaxivities. Proc Int Soc Magn Reson Med. 2008;16:1457.
- Mouridsen K, Christensen S, Gyldensted L, Ostergaard L. Automatic selection of arterial input function using cluster analysis. Magn Reson Med. 2006;55(3):524–531. DOI:https://doi.org/10.1002/mrm.20759.
- Hodge VJ, Austin J. A survey of outlier detection methodologies. Artificial Intelligence Rev. 2004;22(2):85–126. DOI:https://doi.org/10.1023/B:AIRE.0000045502.10941.a9.
- Verardi V, Croux C. Robust regression in Stata. Stata J. 1999;9(3):439–453. DOI:https://doi.org/10.1177/1536867X0900900306.
- Anderson VC, Obayashi JT, Kaye JA, Quinn JF, Berryhill P, Riccelli LP, Peterson D, Rooney WD. Longitudinal relaxographic imaging of white matter hyperintensities in the elderly. Fluids Barriers CNS. 2014;11(1):24. DOI:https://doi.org/10.1186/2045-8118-11-24.
- Akaike H. A new look at the statistical model identification. IEEE Trans Auto Control. 1974;19(6):716–723. DOI:https://doi.org/10.1109/TAC.1974.1100705.
- Jaeger J. Digit Symbol Substitution Test: the case for sensitivity over specificity in neuropsychological testing. J Clin Psychopharmacol. 2018;38(5):513–519. DOI:https://doi.org/10.1097/JCP.0000000000000941.
- Wang J, Fernandez-Seara MA, Wang S, St Lawrence KS. When perfusion meets diffusion: in vivo measurement of water permeability in human brain. J Cereb Blood Flow Metab. 2007;27(4):839–849. DOI:https://doi.org/10.1038/sj.jcbfm.9600398.
- Anderson VC, Tagge IJ, Li X, Quinn JF, Kaye JA, Bourdette DN, Spain RI, Riccelli LP, Sammi MK, Springer CS, et al. Observation of reduced homeostatic metabolic activity and/or coupling in white matter aging. J Neuroimaging. 2020;30(5):658–665. DOI:https://doi.org/10.1111/jon.12744.
- Damkier H, Praetorius J. Structure of the mammalian choroid plexus. In: Praetorius J, Blazer-Yost B, Damkier H, editors. Role of the choroid plexus in health and disease. New York (NY): Springer; 2020. p. 1–33.
- Yang DM, Huettner JE, Bretthorst GL, Neil JJ, Garbow JR, Ackerman JJH. Intracellular water preexchange lifetime in neurons and astrocytes. Magn Reson Med. 2018;79(3):1616–1627. DOI:https://doi.org/10.1002/mrm.26781.
- Tamega OJ, Tirapelli LF, Petroni S. Scanning electron microscopy study of the choroid pleuxus in the monkey (cebus apella apella). Arq Neuropsiquiatr. 2000;58(3B):820–825. DOI:https://doi.org/10.1590/S0004-282X2000000500005.
- Brown PD, Davies SL, Speake T, MIllar ID. Molecular mechanisms of cerebrospinal fluid production. Neuroscience. 2004;129(4):955–968. DOI:https://doi.org/10.1016/j.neuroscience.2004.07.003.
- Zhu X, Cain JR, Wang S, Feldmann M, Thompson G, Li KL, Asselin M, Jackson A. Separation of intra- and extra-vascular spaces in human brain with DCE-MRI and 11C- verapamil PET. Proc Int Soc Mag Reson Med. 2011;19:784.
- Li X, Huang W, Yankeelov TE, Tudorica A, Rooney WD, Springer CS. Shutter-speed analysis of contrast reagent bolus-tracking data: preliminary observations in benign and malignant breast disease. Magn Reson Med. 2005;53:724–729. DOI:https://doi.org/10.1002/mrm.20425.
- Serot J-M, Foliguet B, Bene MC, Faure GC. Choroid plexus and ageing in rats: a morphometric and ultrastructural study. Eur J Neurosci. 2001;14(5):794–798. DOI:https://doi.org/10.1046/j.0953-816x.2001.01693.x.
- Bouzerar R, Chaarani B, Gondry-Jouet C, Zmudka J, Balédent O. Measurement of choroid plexus perfusion using dynamic susceptibility MR imaging: capillary permeability and age-related changes. Neuroradiology. 2013;55(12):1447–1454. DOI:https://doi.org/10.1007/s00234-013-1290-2.
- Evans PG, Sokolska M, Alves A, Harrison IF, Ohene Y, Nahavandi P, Ismail O, Miranda E, Lythgoe MF, Thomas DL, et al. Non-invasive MRI of blood-cerebrospinal fluid barrier function. Nat Commun. 2020;11(1):2081. DOI:https://doi.org/10.1038/s41467-020-16002-4.
- Mortzavi MM, Griessenauer CJ, Adeeb N, Deep A, Shahripour RB, Loukas M, Tubbs RI, Tubbs RS. The choroid plexus: a comprehensive review of its history, anatomy, function, histology, embryology, and surgical considerations. Childs Nerv Syst. 2014;30(2):205–214. DOI:https://doi.org/10.1007/s00381-013-2326-y.
- Schwartz M, Shechter R. Protective autoimmunity functions by intracranial immunosurveillance to support the mind: the missing link between health and disease. Mol Psychiatry. 2010;15(4):342–354. DOI:https://doi.org/10.1038/mp.2010.31.
- Huang W, Chen Y, Fedorov A, Li X, Jajamovich GH, Malyarenko DI, Aryal MP, LaViolette PS, Oborski MJ, O’Sullivan F, et al. The impact of arterial input function determination variations on prostate dynamic contrast-enhanced magnetic resonance imaging pharmacokinetic modeling: a multicenter data analysis challenge. Tomography. 2016;2(1):56–66. DOI:https://doi.org/10.18383/j.tom.2015.00184.
- Lavini C, Verhoeff JJ. Reproducibility of the gadolinium concentration measurements and of the fitting parameters of the vascular input function in the superior sagittal sinus in a patient population. Magn Reson Imag. 2010;28(10):1420–1430. DOI:https://doi.org/10.1016/j.mri.2010.06.017.
- Vaughan JT, Garwood M, Collins CM, Liu W, DelaBarre L, Adriany G, Andersen P, Merkle H, Goebel R, Smith MB, et al. 7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images. Magn Reson Med. 2001;46(1):24–30. DOI:https://doi.org/10.1002/mrm.1156.
- Asllani I, Borogovac A, Brown TR. A regression algorithm correcting for partial volume effects in arterial spin labeling MRI. Magn Reson Med. 2008;60(6):1362–1371. DOI:https://doi.org/10.1002/mrm.21670.