The effect of deflectors on Air Diffusion Performance Index of adjustable diffusers: Cooling condition (RP-1546)

&
Pages 67-74 | Received 14 Oct 2014, Accepted 14 Jul 2015, Published online: 07 Oct 2015

Reference

  • ASHRAE. 2006. ANSI/ASHRAE Standard 70, Method of Testing the Performance of Air Outlets and Air Inlets. Atlanta: ASHRAE.
  • ASHRAE. 2009a. ANSI/ASHRAE Standard-113, Method of Testing for Room Air Diffusion. Atlanta: ASHRAE.
  • ASHRAE. 2009b. ASHRAE Handbook—Fundamentals. Chapter 20. Space Air Diffusion: 14-20. Atlanta, GA: ASHRAE.
  • Chow, W., and L. Wong. 1996. Experimental studies on the air flow characteristics induced by a high sidewall grill in a climate chamber. Indoor and Built Environment 5:82–98.
  • Huang J., and E. Franconi. 1999. Commercial heating and cooling loads component analysis (LBNL-37208):39-45. Berkeley, CA: Lawrence Berkeley National Laboratory.
  • Int-Hout, D. 2013. Slots are adjustable. ASHRAE Journal 55(6):68–70.
  • Koestel, A., and G. Tuve. 1955. Performance and evaluation of room air distribution systems. ASHRAE Transactions 61:533–50.
  • Liu, S., and A. Novoselac. 2014. Lagrangian particle modeling in the indoor environment: A comparison of RANS and LES turbulence methods (RP-1512). Science and Technology for the Built Environment 20(4):480–95.
  • Liu, S., and A. Novoselac. 2015. Air diffusion performance index (ADPI) of diffusers for heating mode. Building and Environment 87:215–23.
  • Miller, P.L. 1971. Room air distribution performance of four selected outlets. ASHRAE Transactions 7(2):194–204.
  • Miller, P.L. 1979. Design of room air diffusion systems using the air diffusion performance index (ADPI). ASHRAE Journal 10:85.
  • Miller, P.L., and R.T. Nash. 1971. A further analysis of room air distribution performance. ASHRAE Transactions 77(2):205–12.
  • Miller, P.L., and R.G. Nevins. 1969. Room air distribution with an air distributing ceiling—Part II. ASHRAE Transactions 75:118.
  • Miller, P.L., and R.G. Nevins. 1970. Room air distribution performance of ventilation ceilings and cone-type circular ceiling diffusers. ASHRAE Transactions 76(1
  • Miller, P.L., and R.G. Nevins. 1972. An analysis of the performance of room air distribution systems. ASHRAE Transactions 78(Part 1):191–8.
  • Nevins, R.G., and P.L. Miller. 1972. Analysis, evaluation and comparison of room air distribution performance—a summary. Research Report ASHRAE RP-55 and 88. ASHRAE, Atlanta.
  • Rydberg, J., P. Norback, and S. Stockholm. 1949. Air distribution and draft. ASHVE Transactions 55:225–40.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.