References
- Ahn, Y.C., J.M. Cho, H.S. Shin, Y.J. Hwang, C.G. Lee, J.K. Lee, H.U. Lee, and T.W. Kang. 2003. An experimental study of the air-side particulate fouling in fin-and-tube heat exchangers of air conditioners. Korean Journal of Chemical Engineering 20(5):873–7.
- Ali, A.H.H., and I.M. Ismail. 2008. Evaporator air-side fouling: Effect on performance of room air conditioners and impact on indoor air quality. HVAC&R Research 14(2):209–19.
- ASHRAE. 2004. ASHRAE Guideline 2-1986 (RA96): Engineering analysis of experimental data. Atlanta: ASHRAE.
- ASHRAE. 2009. ASHRAE Handbook of Fundamentals, Chapter 1. Atlanta: ASHRAE.
- Bahnfleth, W.P. 2011. UVGI in air handlers. ASHRAE Journal 53(4):70–2.
- Bell, I.H., and E.A. Groll. 2011. Air-side particulate fouling of microchannel heat exchangers: Experimental comparison of air-side pressure drop and heat transfer with plate-fin heat exchanger. Applied Thermal Engineering 31(5):742–9.
- Brandemuehl, M.J., and J.D. Bradford. 1998. Implementation of on-line optimal supervisory control of cooling plants without storage. Final report for ASHRAE research project 823-RP.
- Brandemuehl, M.J., S. Gabel, and I. Andresen. 1993. HVAC2 toolkit: Algorithms and subroutines for secondary HVAC system energy calculations. Atlanta: ASHRAE.
- Braun, J.E. 1988. Methodologies for the design and control of central cooling plants. Ph.D Thesis. University of Wisconsin, Madison, Wisconsin, USA.
- Fiorino, D.P. 1999. Achieving high chilled-water delta Ts. ASHRAE Journal 41:24–30.
- Firrantello, J., W.P. Bahnfleth, R. Montgomery, and P. Kremer. 2016. Field study of energy use-related effects of ultraviolet germicidal irradiation of a cooling coil. ASHRAE Transactions 122(1
- Gao, D., S. Wang, K. Shan, and C. Yan. 2016. A system-level fault detection and diagnosis method for low delta-T syndrome in the complex HVAC systems. Applied Energy 164:1028–38.
- Gao, D., S. Wang, Y. Sun, and F. Xiao. 2012. Diagnosis of the low temperature difference syndrome in the chilled water system of a super high-rise building: A case study. Applied Energy 98:597–606.
- Gnielinski, V. 1976. New equation for heat and mass transfer in turbulent pipe and channel flow. International Chemical Engineering 16:359–68.
- Hugenholtz, P., and J.A. Fuerst. 1992. Heterotrophic bacteria in an air-handling system. Applied and Environmental Microbiology 58(12):3914–20.
- Kuehn, T.H., J.W. Ramsey, and J.L. Threlkeld. 1998. Thermal Environmental Engineering. Upper Saddle River, NJ: Prentice-Hall, Inc.
- Liang, S.Y., T.N. Wong, and G.K. Nathan. 2000. Comparison of one-dimensional and two-dimensional models for wet-surface fin efficiency of a plate-fin-tube heat exchanger. Applied Thermal Engineering 20(10):941–62.
- Luongo, J.C., and S.L. Miller. 2016. Ultraviolet germicidal coil cleaning: Decreased surface microbial loading and resuspension of cell clusters. Building and Environment 105:50–5.
- Mendell, M.J., M. Cozen, Q. Lei-Gomez, H.S. Brightman, C.A. Erdmann, J.R. Girman, and S.E. Womble. 2006. Indicators of moisture and ventilation system contamination in U.S. office buildings as risk factors for respiratory and mucous membrane symptoms: Analyses of the EPA BASE data. Journal of Occupational and Environmental Hygiene 3(5):225–33.
- Mendell, M.J., Q. Lei-Gomez, A.G. Mirer, O. Seppanen, and G. Brunner. 2008. Risk factors in heating, ventilating, and air-conditioning systems for occupant symptoms in US office buildings: The U.S. EPA BASE study. Indoor Air 18(4):301–16.
- Mendell, M.J., G.M. Naco, T.G. Wilcox, and W.K. Sieber. 2003. Environmental risk factors and work-related lower respiratory symptoms in 80 office buildings: An exploratory analysis of NIOSH data. American Journal of Industrial Medicine 43(6):630–41.
- Moffat, R.J. 1988. Describing the uncertainties in experimental results. Experimental Thermal and Fluid Science 1(1):3–17.
- Montgomery, R.D., and R. Baker. 2006. Study verifies coil cleaning saves energy. ASHRAE Journal 48(11):34–6.
- Pak, B.C., B.J. Baek, and E.A. Groll. 2003. Impacts of fouling and cleaning on the performance of plate fin and spine fin heat exchangers. KSME International Journal 17(11):1801–11.
- Pu, H., G. Ding, X. Ma, H. Hu, and Y. Gao. 2009. Effects of biofouling on air-side heat transfer and pressure drop for finned tube heat exchangers. International Journal of Refrigeration 32(5):1032–40.
- Siegel, J.A. 2012. Particulate fouling of HVAC heat exchangers. Ph.D Thesis. University of California, Berkeley, California, USA.
- Taylor, S.T. 2002. Degrading chilled water plant delta-T: Causes and mitigation. ASHRAE Transactions 108(1):641–53.
- U.S. Department of Energy. 2014. Chilled-Water-Based Air Cooling Coil. Washington, D.C.: EnergyPlus Engineering Reference.
- Wetter, M. 1999. Simulation Model: Finned Water-to-Air Coil Without Condensation. Berkeley, CA: Lawrence Berkeley National Laboratory.
- Wilson, S.C., R.N. Palmatier, L.A. Andriychuk, J.M. Martin, C.A. Jumper, H.W. Holder, and D.C. Straus. 2007. Mold contamination and air handling units. Journal of Occupational and Environmental Hygiene 4(7):483–91.
- Yang, L., J.E. Braun, and E.A. Groll. 2007. The impact of fouling on the performance of filter–evaporator combinations. International Journal of Refrigeration 30(3):489–98.