REFERENCES
- Zang , Y. , Xie , S. J. and Pan , J. H. 1997 . Determination of Strontium in Human Hair by Air-acetylene Flame Atomic-absorption Spectrometry in the Presence of Surfactant OP . Fenxi Shiyanshi , 16 ( 2 ) : 81
- Altzitzoglou , T. , Larosa , J. J. and Nicholl , C. 1998 . Measurement of Strontium-90 in Bone Ash . Appl. Radiat. Isot. , 49 ( 9–11 ) : 1313
- Perez-Jordan , M. Y. , Salvador , A. and de la Guardia , M. 1998 . Determination of Strontium, Potassium, Magnesium and Sodium in Human Teeth by Atomic Spectrometry using a Microwave-assisted Digestion in a Closed Flow System . Anal. Lett. , 31 ( 5 ) : 867
- Baumann , E. W. 1975 . Preparation and Properties of Strontium Selective Electrode . Anal. Chem. , 47 : 959
- Akmal , N. , Zimmer , H. and Mark , H. B. 1991 . Strontium Ion-selective Electrode Based on Conducting Poly(dibenzo-18-crown-6) Film . Anal. Lett. , 24 : 1431
- Qian , G. , Wu , M. B. , Wu , G. , Huang , S. , Yan , Y. and Tian , B. 1998 . Strontium Ion-Selective Electrode Based on the Diamides with Pyridine Ring as Ionophores . Talanta , 47 : 1149
- Shamsipur , M. , Rouhani , S. , Sharghi , H. , Ganjali , M. R. and Eshghi , H. 1999 . Strontium-Selective Membrane Electrode Based on some Recently Synthesized Benzo-substituted Macrocyclic Diamides . Anal. Chem. , 71 : 4938
- Hauser , C. R. , Swamer , F. W. and Ringler , B. I. 1948 . Alkaline Cleavages of Unsymmetrical β-diketones Ring Opening of Acyclohexanonanes to form E-alyl Caproic Acids . J. Am. Chem. Soc. , 70 : 4023
- Morf , W. E. 1981 . The Principles of Ion-Selective Electrodes and Membrane Transport Amsterdam : Elsevier .
- Buck , R. P. and Cosofret , V. V. 1993 . Recommended Procedure for Calibration of Ion-Selective Electrodes . Pure Appl. Chem. , 65 : 1849
- Buck , R. P. and Linder , E. 1994 . Recommendations for Nomenclature of Ion-selective Electrodes . Pure Appl. Chem. , 66 : 2527
- Morf , W. E. , Kahr , G. and Simon , W. 1974 . Reduction of the Anion Interference in Neutral Carrier Liquid-membrane Electrodes Responsive to Cations . Anal. Lett. , 7 : 9
- Morf , W. E. , Ammann , D. and Simon , W. 1974 . Elimination of the Anion Interference in Neutral Carrier Cation-selective Membrane Electrodes . Chimia , 28 : 65
- Ammann , D. , Morf , W. E. , Anker , P. , Meier , P. C. , Pretsch , E. and Simon , W. 1983 . Neutral Carrier Based Ion-selective Electrodes . Ion-Sel. Electrode Rev. , 5 : 3
- Meier , P. C. , Morf , W. E. , Laubli , M. and Simon , W. 1984 . Evaluation of Optimum Composition of Neutral-carrier Membrane Electrodes with Incorporated Cation-exchanger Sites . Anal. Chim. Acta , 156 : 1
- Mikhelson , K. N. 1994 . Ion-selective Electrodes in PVC Matrix . Sens. Actuators , 18 : 31
- Saez de Viteri , F. J. and Diamond , D. 1994 . Determination and Application of Ion-selective Electrodes Model Parameters using Flow Injection and Simplex Optimization . Analyst , 119 : 749