64
Views
16
CrossRef citations to date
0
Altmetric
Original Articles

A POLYMERIC BILAYER CONFIGURATION FOR A CHOLESTEROL AMPEROMETRIC BIOSENSOR BASED ON THE COMBINATION OF OVEROXIDIZED POLYPYRROLE AND A POLYNAPHTHALENE DERIVATIVE

, , &
Pages 837-853 | Received 05 Nov 2001, Accepted 08 Jan 2002, Published online: 02 Feb 2007

REFERENCES

  • Vidal , J.C. , Garcia-Ruiz , E. and Castillo , J.R. 2001 . Design of a Multilayer Cholesterol Amperometric Biosensor for Preparation and Use in Flow Systems . Electroanalysis , 13 ( 3 ) : 229 – 235 .
  • Vidal , J.C. , Garcia-Ruiz , E. and Castillo , J.R. 2000 . Strategies for the Improvement of an Amperometric Cholesterol Biosensor Based on Electropolymerization in Flow Systems-Use of Charge-Transfer Mediators and Platinization of the Electrode . J. Pharm. Biomed. Anal. , 24 ( 1 ) : 51 – 63 .
  • Nakaminami , T. , Ito , S. , Kuwabata , S. and Yoneyama , H. 1999 . Amperometric Determination of Total Cholesterol at Gold Electrodes Covalently Modified with Cholesterol Oxidase and Cholesterol Esterase with Use of Thionin as an Electron Mediator . Anal. Chem. , 71 ( 5 ) : 1068 – 1076 .
  • Habermuller , K. , Ramanavicius , A. , Laurinavicius , V. and Schuhmann , W. 2000 . An Oxygen-Insensitive Reagentless Glucose Biosensor Based on Osmium-Complex Modified Polypyrrole . Electroanalysis , 12 ( 17 ) : 1383 – 1389 .
  • Piro , B. , Do , V.A. , Le , L.A. , Hedayatullah , M. and Pham , M.C. 2000 . Electrosynthesis of a New Enzyme-Modified Electrode for the Amperometric Detection of Glucose . J. Electroanal. Chem. , 486 ( 2 ) : 133 – 140 .
  • Cui , G. , Kim , S.J. , Choi , S.H. , Nam , H. , Cha , G.S. and Paeng , K.-J. 2000 . A Disposable Amperometric Sensor Screen-Printed on a Nitrocellulose Strip—A Glucose Biosensor Employing Lead-Oxide as an Interference-Removing Agent . Anal. Chem. , 72 ( 19 ) : 1925 – 1929 .
  • Yamazaki , T. , Kojima , K. and Sode , K. 2000 . Extended-Range Glucose Sensor Employing Engineered Glucose Dehydrogenases . Anal. Chem. , 72 ( 19 ) : 4689 – 4693 .
  • Yang , Y. , Zhang , S.F. , Kingston , M.A. , Jones , G. , Wright , G. and Spencer , S.A. 2000 . Glucose Sensor with Improved Hemocompatibility . Biosens. Bioelectron. , 15 ( 5–6 ) : 221 – 227 .
  • Yoon , H.J. , Cui , G. , Yoo , J.H. , Nam , H. and Cha , G.S. 2000 . Interference-Free Differential Thick-Film Amperometric Glucose Sensor for Point-of-Care Testing . Clin. Chem. , 46 ( 6 ) : 230 – 230 .
  • Cleeman , J.I. and Lenfant , C. 1998 . The National Cholesterol Education-Program—Progress and Prospects . JAMA J. Am. Med. Assoc. , 280 ( 2 ) : 2099 – 2104 .
  • Ansell , B.J. , Watson , K.E. and Fogelman , A.M. 1999 . An Evidence-Based Assessment of the NCEP Adult Treatment Panel-II Guidelines . JAMA J. Am. Med. Assoc. , 282 ( 21 ) : 2051 – 2057 .
  • Yang , Q.L. , Atanasov , P. and Wilkins , E. 1998 . An Integrated Needle-Type Biosensor for Intravascular Glucose and Lactate Monitoring . Electroanalysis , 10 ( 11 ) : 752 – 757 .
  • Garjonyte , R. and Malinauskas , A. 1999 . Amperometric Glucose Biosensor Based on Glucose-Oxidase Immobilized in Poly(o-phenylenediamine) Layer . Sens. Actuators B , 56 ( 1–2 ) : 85 – 92 .
  • Xu , J.-J. and Chen , H.-Y. 2000 . Amperometric Glucose Sensor-Based on Coimmobilization of Glucose-Oxidase and Poly(p-Phenylenediamine) at a Platinum Microdisk Electrode . Anal. Biochem. , 280 ( 2 ) : 221 – 226 .
  • Karalemas , I.D. , Georgiou , C.A. and Papastathopoulos , D.S. 2000 . Construction of a l-Lysine Biosensor by Immobilizing Lysine Oxidase on a Gold-Poly(o-phenylenediamine) Electrode . Talanta , 53 ( 2 ) : 391 – 402 .
  • Nakabayashi , Y. , Wakuda , M. and Imai , H. 1998 . Amperometric Glucose Sensors Fabricated by Electrochemical Polymerization of Phenols on Carbon-Paste Electrodes Containing Ferrocene as an Electron-Transfer Mediator . Anal. Sci. , 14 ( 6 ) : 1069 – 1076 .
  • Vidal , J.C. , Garcia , E. and Castillo , J.R. 1998 . Electropolymerization of Pyrrole and Immobilization of Glucose-Oxidase in a Flow System—Influence of the Operating-Conditions on Analytical Performance . Biosens. Bioelectron. , 13 ( 3–4 ) : 371 – 382 .
  • Vidal , J.C. , Garcia , E. and Castillo , J.R. 1999 . In-Situ Preparation of a Cholesterol Biosensor—Entrapment of Cholesterol Oxidase in an Overoxidized Polypyrrole Film Electrodeposited in a Flow System—Determination of Total Cholesterol in Serum . Anal. Chim. Acta , 385 ( 1–3 ) : 213 – 222 .
  • Palmisano , F. , Malitesta , C. , Centonze , D. and Zambonin , P.G. 1995 . Correlation Between Permselectivity and Chemical-Structure of Overoxidized Polypyrrole Membranes Used in Electroproduced Enzyme Biosensors . Anal. Chem. , 67 ( 13 ) : 2207 – 2211 .
  • Vidal , J.C. , Garcia , E. and Castillo , J.R. 1999 . In-Situ Preparation of Overoxidized PPy/oPPD Bilayer Biosensors for the Determination of Glucose and Cholesterol in Serum . Sens. Actuators B , 57 ( 1–3 ) : 219 – 226 .
  • Murphy , L.S. 1998 . Reduction of Interference Response at a Hydrogen-Peroxide Detecting Electrode Using Electropolymerized Films of Substituted Naphthalenes . Anal. Chem. , 70 ( 14 ) : 2928 – 2935 .
  • Ciriello , R. , Cataldi , T.R.I. , Centonze , D. and Guerrieri , A. 2000 . Permselective Behavior of an Electrosynthesized, Nonconducting Thin-Film of Poly(2-naphthol) and Its Application to Enzyme Immobilization . Electroanalysis , 12 ( 11 ) : 825 – 830 .
  • Jackowska , K. , Skompska , M. and Przyluska , E. 1996 . Electrooxidation of 1,5-Diaminonaphthalene and 1,8-Diaminonaphthalene—An RDE Study . J. Electroanal. Chem. , 418 ( 1–2 ) : 35 – 39 .
  • Kurganov , B.I. , Lobanov , A.V. , Borisov , I.A. and Reshetilov , A.N. 2001 . Criterion for Hill Equation Validity for Description of Biosensor Calibration Curves . Anal. Chim. Acta , 427 ( 1 ) : 11 – 19 .

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.