REFERENCES
- Taguchi , S. , Kasahara , I. , Fukushima , Y. and Goto , K. 1981 . An application of bis[2‐(5‐chloro‐2‐pyridylazo)‐5‐diethylaminophenolato] cobalt (III) chloride to the extraction and spectrophotometric determination of sulphonated and sulphatesurfactants . Talanta , 28 : 616 – 617 .
- Japanese Industrial Standard Committee . 1986 . JIS-K 0120 , Tokyo : Japanese Standards Association .
- Motomizu , S. , Fujiwara , S. , Fujiwara , A. and Toei , K. 1982 . Solvent extraction‐spectrophotometric determination of anionic surfactants with ethyl violet . Anal. Chem. , 54 : 392 – 397 .
- Masadome , T. , Imato , T. and Ishibashi , N. 1987 . Surfactant‐selective electrode based on plasticized poly(vinyl chloride) membrane and its application . Anal. Sci. , 3 : 121 – 124 .
- Ishibashi , N. , Masadome , T. and Imato , T. 1986 . Surfactant‐selective electrode based on poly(vinyl chloride) membrane plasticized with o‐nitrophenyl octyl ether . Anal. Sci. , 2 : 487 – 488 .
- Masadome , T. , Yang , J. G. , Imato , T. and Ishibashi , N. 1992 . Anion response characteristics of an electrode based on plasticized poly(vinyl chloride) membrane without added ion exchanger . Bunseki Kagaku , 41 : 231 – 237 .
- Masadome , T. , Imato , T. , Wakida , S. , Higashi , K. and Asano , Y. 2000 . Relationship between the hydrophobicity of cations and the cationic response of a plasticized poly(vinyl chloride) membrane electrode with no added ion‐exchanger . Anal. Sci. , 16 : 383 – 388 .
- Masadome , T. , Imato , T. , Hachiya , H. and Asano , Y. 1998 . Flow injection determination of dodecylsulfate using a dodecylsulfate‐selective plasticized poly(vinyl chloride) membrane electrode detector . J. Flow Injection Anal. , 15 : 242 – 247 .
- Masadome , T. , Imato , T. and Ishibashi , N. 1990 . Flow injection analysis of nonionic surfactants using ionic surfactant‐selective electrode detector . Anal. Sci. , 6 : 605 – 606 .
- Masadome , T. , Imato , T. and Ishibashi , N. 1990 . Flow injection analysis of nonionic surfactants with plasticized poly(vinyl chloride) membrane electrode detector . Bunseki Kagaku , 39 : 519 – 522 .
- Masadome , T. , Imato , T. and Ishibashi , N. 1991 . FIA of cationic surfactants using plasticized polyvinyl chloride membrane electrode . Bunseki Kagaku , 40 : 1 – 6 .
- Masadome , T. , Imato , T. and Ishibashi , N. 1991 . FIA of nonionic surfactants using plasticized polyvinyl chloride membrane electrode and a micro‐column packed with an ion‐exchange resin . Bunseki Kagaku , 40 : 7 – 11 .
- Takehara , K. , Takemura , H. and Ide , Y. 1994 . Electrochemical studies of the terminally substituted alkanethiol monolayers formed on a gold electrode: effects of the terminal group on the redox responses of Fe(CN)6 3− and Ru (NH3)6 3+ and ferrocenedimethanol . Electrochim. Acta , 39 : 817 – 822 .
- Takehara , K. and Takemura , H. 1995 . Electrochemical behaviors of ferrocene derivatives at an electrode modified with terminally substituted alkanethiol monolayer assemblies . Bull. Chem. Soc. Jpn. , 68 : 1289 – 1296 .
- Chen , Z. and Nagaoka , T. 2000 . Recognition of vitamin K1 with a molecularly imprinted self‐assembled monolayer film . Bunseki Kagaku , 49 : 543 – 545 .
- Gadzekpo , V. P. Y. , Xiao , K. P. , Aoki , H. , Bühlmann , P. and Umezawa , Y. 1999 . Voltammetric detection of the polycation protamine by the use of electrodes modified with self‐assembled monolayers of thioctic acid . Anal. Chem. , 71 : 5109 – 5115 .
- Gadzekpo , V. P. Y. , Bühlmann , P. , Xiao , K. P. , Aoki , H. and Umezawa , Y. 2000 . Development of an ion‐channel sensor for heparin detection . Anal. Chim. Acta , 411 : 163 – 173 .
- Wang , J. , Zeng , B. , Fang , C. and Zhou , X. 2000 . The influence of surfactants on the electron‐transfer reaction at self‐assembled thiol monolayers modifying a gold electrode . J. Electroanal. Chem. , 484 : 88 – 92 .
- Kawaguchi , T. , Yamauchi , Y. , Maeda , H. and Ohmori , H. 1992 . Amperometric determination of surfactants using a gold electrode modified with a self‐assembled monolayers of stearylthiol . Anal. Sci. , 8 : 691 – 692 .
- Kawaguchi , T. , Yamauchi , Y. , Maeda , H. and Ohmori , H. 1993 . Gold electrode modified with a self‐assembled monolayer of thiols as an electrochemical detector for ionic surfactants . Chem. Pharm. Bull. , 41 : 1601 – 1603 .
- Gerlache , M. , Kauffmann , J. M. , Quarin , G. , Vire , J. C. , Bryant , G. A. and Talbot , J. M. 1996 . Electrochemical analysis of surfactants: an overview . Talanta , 43 : 507 – 519 .
- Gerlache , M. , Senturk , Z. , Quarin , G. and Kauffmann , J. M. 1997 . Self‐assembled monolayer gold electrode for surfactant analysis . J. Solid State Electrochem. , 1 : 155 – 160 .