235
Views
18
CrossRef citations to date
0
Altmetric
Mini‐Review

The Three Generations of Flow Injection Analysis

&
Pages 345-359 | Received 01 Dec 2003, Accepted 01 Dec 2003, Published online: 22 Aug 2007

References

  • Ruzicka , J. and Hansen , E. H. 1975 . Flow injection analysis. Part I. A new concept of fast continuous flow analysis . Anal. Chim. Acta , 78 : 145 – 157 .
  • Hansen , E. H. 2003 . Flow Injection Bibliography http://www.flowinjection.com, 2003
  • Ruzicka , J. 1998 . Two anniversaries and three generations . J. Flow Injection Anal. , 15 ( 2 ) : 151 – 152 .
  • Ruzicka , J. and Marshall , G. D. 1990 . Sequential injection: a new concept for chemical sensors, process analysis and laboratory assays . Anal. Chim. Acta , 237 ( 2 ) : 329 – 343 .
  • Ruzicka , J. 2000 . Lab‐on‐valve: universal microflow analyzer based on sequential and bead injection . Analyst , 125 ( 6 ) : 1053 – 1060 .
  • Ruzicka , J. and Hansen , E. H. 1988 . Flow Injection Analysis , 2nd Ed. New York , , USA : John Wiley and Sons, Inc. .
  • Fang , Z. L. 1993 . “ Gas‐liquid separation ” . In Flow Injection Separation and Preconcentration 129 – 157 . Weinheim : VCH . Ch. 5
  • Bendtsen , A. B. and Hansen , E. H. 1991 . Spectrophotometric flow injection determination of trace amounts of thiocyanate based on its reaction with 2‐(5‐bromo‐2‐pyridylazo)‐5‐diethylaminophenol and dichromate: assay of the thiocyanate level in saliva from smokers and non‐smokers . Analyst , 116 : 647 – 651 .
  • Hansen , E. H. 1994 . Flow injection analysis: a complementary or alternative concept to biosensors . Talanta , 41 ( 6 ) : 939 – 948 .
  • Hansen , E. H. 1988 . Exploitation of gradient techniques in flow injection analysis . Fresenius' Z. Anal. Chem. , 329 : 656 – 659 .
  • Fang , Z. L. 1989 . “ Analytical methods and techniques ” . In Flow Injection Atomic Spectroscopy , Practical Spectroscopy Series Edited by: Burguera , J. L. Vol. 7 , 103 – 156 . New York : Marcel Dekker Inc . Ch. 4
  • Fang , Z. L. 1995 . “ On‐line preconcentration for flame and hydride generation of atomic absorption spectometry; and flow injection tehcnique for electrothermal atomic absorption spectometry ” . In Flow Injection Atomic Spectrometry 143 – 174 . 175 – 202 . New York : John Wiley & Sons Ltd . Chs. 8 & 9
  • Wang , J.‐H. and Hansen , E. H. 2002 . Development of an automated sequential injection on‐line solvent extraction–back extraction procedure as demonstrated for the determination of cadmium with detection by electrothermal atomic absorption spectrometry . Anal. Chim. Acta , 456 : 283 – 292 .
  • Wang , J.‐H. and Hansen , E. H. 2002 . FI/SI on‐line solvent extraction/back extraction preconcentration coupled to direct injection nebulization inductively coupled plasma mass spectrometry for determination of copper and lead . J. Anal. At. Spectrom. , 17 ( 10 ) : 1284 – 1289 .
  • Oliveira , C. C. , Sartini , R. P. and Zagatto , E. A.G. 2000 . Microwave‐assisted sample preparation in sequential injection: spectrophotometric determination of magnesium, calcium, and iron in food . Anal. Chim. Acta , 413 ( 1–2 ) : 41 – 48 .
  • van Staden , J. F. , Mashamba , M. G. and Stefan , R. I. 2002 . Determination of the total acidity in soft drinks using potentiometric sequential injection titration . Talanta , 58 ( 6 ) : 1109 – 1114 .
  • Baxter , P. J. and Christian , G. D. 1996 . Sequential injection analysis—a versatile technique for bioprocess monitoring [Review] . Acc. Chem. Res. , 29 ( 11 ) : 515 – 521 .
  • Cerda , V. , Cerda , A. , Cladera , A. , Oms , M. T. , Mas , F. , Gomez , E. , Bauza , F. , Miro , M. , Forteza , R. and Estela , J. M. 2001 . Monitoring of environmental parameters by sequential injection analysis . Trends Anal. Chem. , 20 ( 8 ) : 407 – 418 .
  • Liu , X. Z. and Fang , Z. L. 2000 . The automation of pharmaceutical analysis using sequential‐injection techniques . Lab. Rob. Autom. , 12 ( 2 ) : 60 – 66 .
  • Barnett , N. W. , Lenehan , C. E. and Lewis , S. W. 1999 . Sequential injection analysis: an alternative approach to process analytical chemistry . Trends. Anal. Chem. , 18 ( 5 ) : 346 – 353 .
  • Wu , C. H. , Scampavia , L. , Ruzicka , J. and Zamost , B. 2001 . Micro sequential injection: fermentation monitoring of ammonia, glycerol, glucose, and free iron using the novel lab‐on‐valve system . Analyst , 126 ( 3 ) : 291 – 297 .
  • Hansen , E. H. and Wang , J.‐H. 2002 . Implementation of suitable FI/SI‐sample separation/preconcentration schemes for determination of trace metal concentrations using detection by ETAAS and ICPMS . Anal. Chim. Acta , 467 : 3 – 12 .
  • Wang , J.‐H. and Hansen , E. H. 2003 . Sequential injection lab‐on‐valve: the third generation of flow injection analysis . Trends Anal. Chem. , 22 ( 4 ) : 225 – 231 .
  • Wang , J.‐H. and Hansen , E. H. 2000 . Coupling on‐line preconcentration by ion‐exchange with ETAAS. A novel flow injection approach based on the use of a renewable micro‐column as demonstrated for the determination of nickel in environmental and biological samples . Anal. Chim. Acta , 424 : 223 – 232 .
  • Wang , J.‐H. and Hansen , E. H. 2001 . Coupling sequential injection on‐line preconcentration by means of a renewable microcolumn with ion‐exchange beads with detection by electrothermal atomic absorption spectrometry. Comparing the performance of eluting the loaded beads with transporting them directly into the graphite tube, as demonstrated for the determination of nickel in environmental and biological samples . Anal. Chim. Acta , 435 : 331 – 342 .
  • Wang , J.‐H. and Hansen , E. H. 2001 . On‐line ion exchange preconcentration in a sequential injection lab‐on‐valve microsystem incorporating a renewable column with ETAAS for the trace‐level determination of bismuth in urine and river sediment . Atom. Spectrosc. , 22 ( 3 ) : 312 – 318 .
  • Miró , M. , Jończyk , S. , Wang , J.‐H. and Hansen , E. H. 2003 . Exploiting the bead‐injection approach in the integrated sequential injection lab‐on‐valve format using hydrophobic packing materials for on‐line matrix removal and preconcentration of trace levels of cadmium in environmental and biological samples via formation of non‐charged chelates prior to ETAAS detection . J. Anal. At. Spectrom. , 18 ( 2 ) : 89 – 98 .
  • Hodder , P. S. , Beeson , C. and Ruzicka , J. 2000 . Equilibrium and kinetic measurements of muscarinic receptor antagonism on living cells using bead injection spectroscopy . Anal. Chem. , 72 ( 14 ) : 3109 – 3115 .
  • Ruzicka , J. and Scampavia , L. 1999 . From flow injection to bead injection . Anal. Chem. , 71 ( 7 ) : 257A – 263A .
  • Wu , C.‐H. , Scampavia , L. and Ruzicka , J. 2002 . Microsequential injection: anion separations using ‘lab‐on‐valve’ coupled with capillary electrophoresis . Analyst , 127 ( 7 ) : 898 – 905 .

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.