1,213
Views
110
CrossRef citations to date
0
Altmetric
Original Articles

MID-INFRARED AND RAMAN SPECTROSCOPY FOR MEDICAL DIAGNOSTICS

Pages 181-237 | Published online: 27 Oct 2011

REFERENCES

  • Kalasinsky , V. F. 1996 . Biomedical applications of infrared and Raman spectroscopy . Appl. Spectrosc. Rev. , 31 ( 3 ) : 193 – 249 .
  • Carmona , P. , Navarro , R. and Hernanz , A. 1997 . Spectroscopy of biological molecules: Modern trends Dordrecht, , The Netherlands : Kluwer Academic Publishers .
  • Mantsch , H. H. and Jackson , M. , eds. 1998 . Infrared Spectroscopy: New Tool in Medicine. Proc. SPIE Vol. 3257 ,
  • Shaw , R. A. and Mantsch , H. H. 1999 . Vibrational biospectroscopy: from plants to animals to humans. A historical perspective . J. Mol. Struct. , 480/481 : 1 – 13 .
  • Schrader , B. , Dippel , B. , Erb , I. , Keller , S. , Lochte , T. , Schultz , H. , Tatsch , E. and Wessel , S. 1999 . NIR Raman spectroscopy in medicine and biology: results and aspects . J. Mol. Struct. , 480/481 : 21 – 32 .
  • Mahadevan-Jansen , A. and Puppels , G. , eds. 2000 . Biomedical Spectroscopy: Vibrational spectroscopy and other novel techniques. Proc. SPIE Vol. 3918 ,
  • Carden , A. and Morris , M. D. 2000 . Application of vibrational spectroscopy to the study of mineralized tissue (review) . J. Biomed. Optics , 5 ( 3 ) : 259 – 268 .
  • Salzer , R. , Steiner , G. , Mantsch , H. H. , Mansfield , J. and Lewis , E. N. 2000 . Infrared and Raman imaging of biological and biomimetic samples . Fresenius J. Anal. Chem. , 366 : 712 – 726 .
  • Gremlich , H.-U. and Yan , B. , eds. 2001 . Infrared and Raman Spectroscopy of Biological Materials New York : Marcel Dekker, Inc .
  • In general, however, the oscillations are only approximately harmonic and inharmonic terms lead to so-called overtones. The wavelengths of overtone oscillations are typically in the near infrared between 1 μm and 2.5 μm. Although overtone signals tend to be weaker than those observed by direct viewing of the fundamental oscillations, the spectroscopy of overtones is a vivid field of research and application. However, for the sake of simplicity this manuscript will not cover the medical application of near-infrared spectroscopy as indicated by the choice of the title
  • Schrader , B. , ed. 1995 . Infrared and Raman spectroscopy Weinheim : VCH Verlagsgesellschaft mbH .
  • Mirabell , F. M. , ed. 1998 . Modern techniques in applied molecular spectroscopy New York : John Wiley & Sons, Inc. .
  • Clarke , R. H. , Hanlon , E. H. , Isner , J. M. and Brody , H. 1987 . Laser Raman spectroscopy of calcified artheriosclerotic lesions in cardiovascular tissue . Appl. Opt. , 26 : 3175 – 3176 .
  • Clarke , R. H. , Wang , Q. and Isner , J. M. 1988 . Laser Raman spectroscopy of artherosclerotic lesions in human coronary artery segments . Appl. Opt. , 27 : 4799 – 4800 .
  • Baraga , J. J. , Feld , M. S. and Rava , R. P. 1992 . In situ optical histochemistry of human artery using near-infrared Fourier transform Raman spectroscopy . Proc.Natl.Acad.Sci. USA , 89 : 3472 – 7 .
  • Baraga , J. J. , Feld , M. S. and Rava , R. P. 1992 . Rapid near-IR Raman spectroscopy of human tissue with a spectrograph and a CCD detector . Appl. Spectrosc. , 46 : 187 – 190 .
  • Brennan , J. F. III , Romer , T. J. , Lees , R. S. , Tercyak , A. M. , Kramer , J. R. and Feld , M. S. Jr. 1997 . Determination of human coronary artery composition by Raman spectroscopy . Circulation , 96 : 99 – 105 .
  • Romer , T. J. , Brennan , J. F. III , Baker Schutt , T. C. , Wolthuis , R. , van den Hoogen , R. C.M. , Emeis , J. J. , van der Laarse , A. , Bruschke , A. V.G. and Puppels , G. J. 1998 . Raman spectroscopy for quantifying cholesterol in intact coronary artery wall . Atherosclerosis , 141 : 117 – 124 .
  • Romer , T. J. , Brennan , J. F. III , Fitzmaurice , M. , Feldstein , M. L. , Deinum , G. , Myles , J. L. , Kramer , J. R. , Lees , R. S. and Feld , M. S. 1998 . Histopathology of human coronary arteriosclerosis by quantifying its chemical composition with Raman spectroscopy . Circulation , 97 : 878 – 885 .
  • Schrader , B. , Dippel , B. , Fendel , S. , Keller , S. , Löchte , T. , Riedl , M. , Schulte , R. and Tatsch , E. 1997 . NIR FT Raman spectroscopy—a new tool in medical diagnostics . J. Mol. Struc. , 408/409 : 23 – 31 .
  • Werner , G. H. , Boecker , D. , Haar , H. P. , Kuhr , H. J. and Mischler , R. Multicomponent assay for blood substrates in human sera and hemolysed blood by mid-infrared spectroscopy , In Reference [3], pp.91–100
  • Kostrewa , S. , Paarmann , Ch. , Goemann , W. and Heise , H. M. 1998 . Multivariate determination of hematocrit in whole blood by attenuated total reflection infrared spectroscopy . Fourier Transform Spectroscopy: 11th International Conference . 1998 , New York. Edited by: de Haseth , J. A . Vol. 430 , pp. 271 – 273 . American Institute of Physics, AIP Conf. Proc. .
  • Berger , A. J. , Koo , T.-W. , Itzkan , I. , Horowitz , G. and Feld , M. S. 1999 . Multicomponent blood analysis by near-infrared Raman spectroscopy . Appl. Optics , 38 ( 13 ) : 2916 – 2926 .
  • Schultz , C. P. , Ahmed , M. K. , Dawes , C. and Mantsch , H. H. 1996 . Thiocyanate levels in human saliva: quantitation by Fourier transform infrared spectroscopy . Anal. Biochem , 240 : 7 – 12 .
  • Benedetti , E. , Bramati , E. , Papineschi , F. , Rossi , I. and Benedetti , E. 1997 . Determination of the relative amount of nucleic acids and proteins in leukemic and normal lymphocytes by means of Fourier transform infrared microspectroscopy . Appl. Spectrosc. , 51 : 792 – 797 .
  • Liu , K. Z. , Schultz , C. P. , Mohammad , R. M. , Al-Katib , A. M. , Johnston , J. B. and Mantsch , H. H. 1998 . Similarities between the sensitivity to 2-chlorodeokyadenosineof lymphocytes from CLL patients and bryostatin 1-treated WSU-CLL cells: an infrared spectroscopic study . Cancer Lett. , 127 : 185 – 193 .
  • Diem , M. , Boydston-White , S. and Chiriboga , L. 1999 . Infrared spectroscopy of cells and tissue: shining light onto a novel subject . Appl. Spectrosc. , 53 : 148A – 161A .
  • Wood , B. R. , Tait , B. and McNaugthon , D. 2000 . Fourier Transform infrared spectroscopy as a method for monitoring the molecular dynamics of lymphocyte activation . Appl. Spectrosc. , 54 : 353 – 359 .
  • Arnett , F. C , Edworthy , S. M. , Bloch , D. A. , McShane , D. J. , Fries , J. F. , Cooper , N. S. , Healy , L. A. , Kaplan , S. R. , Liang , M. H. , Luthra , H. S. , Medsger , T. A. , Mitchell , D. M. , Neustadt , D. H. , Pinals , R. S. , Schaller , J. G. , Sharp , J. T. , Wilder , R. L. and Hunder , G. G. 1988 . The American Rheumatism Association 1987 revised criteria for the classification of rheumatoid arthritis . Arthritis Rheum. , 31 : 315 – 324 .
  • Eysel , H. H. , Jackson , M. , Nikulin , A. , Somorjai , R. , Thompson , G. T.D. and Mantsch , H. H. 1997 . A novel diagnostics test for arthritis: multivariate analysis of infrared spectra of synovial fluid . Biospectrosc. , 3 : 161 – 167 .
  • Shaw , R. A. , Eysel , H. H. , Liu , K. Z. and Mantsch , H. H. 1998 . Infrared Spectroscopic Analysis of biomedical specimens using glass substrates . Anal. Biochem. , 259 : 181 – 186 .
  • Staib , A. , Dolenko , B. , Fink , D. J. , Früh , J. , Nikulin , A. E. , Otto , M. , Pessin-Minsley , M. S. , Quarder , O. , Somorjai , R. , Thienel , U. , Werner , G. and Petrich , W. 2001 . Disease pattern recognition testing for rheumatoid arthritis using infrared spectra of human serum . Clin. Chim. Acta , 308 : 79 – 98 .
  • Petrich , W. , Staib , A. , Otto , M. and Somorjai , R. in press . Correlation between the state of health of blood donors and the corresponding mid-infrared spectra of the serum . Vib. Spectrosc. ,
  • Swet , J. A. 1988 . Measuring the accuracy of diagnostic systems . Science , 240 : 1285 – 1293 .
  • Heise , H. M. and Bittner , A. 1995 . Investigation of experimental errors in the quantitative analysis of glucose in human blood plasma by ATR-spectroscopy . J. Mol. Struct. , 348 : 21 – 24 .
  • Budinova , A. , Salva , J. and Volka , K. 1997 . Application of molecular spectroscopy in the mid-infrared region to the determination of glucose and cholesterol in whole blood and in blood serum . Appl. Spectrosc. , 51 : 631 – 635 .
  • Berger , A. J. , Itzkan , I. and Feld , M. S. 1997 . Feasibility of measuring blood glucose concentration by near-infrared Raman spectroscopy . Spectrochim. Acta , 53 ( Part A ) : 287 – 292 .
  • Vonach , R. , Buschmann , J. , Falkowski , R. , Schindler , R. , Lendl , B. and Kellner , R. 1998 . Application of mid-infrared transmission spectroscopy to direct determination of glucose in whole blood . Appl. Spectrosc. , 52 ( 6 ) : 820 – 822 .
  • Heise , H. M. and Marbach , R. 1998 . Human oral mucosa studies with varying blood glucose concentration by non-invasive ATR-FT-IR spectroscopy . Cell. Mol. Biol. , 44 : 899 – 912 .
  • Gotshal , Y. , Adam , I. and Katzir , A. 1998 . Glucose measurements in solutions using fiber optic evanscent wave spectroscopy and tunable CO2 laser . Proc. SPIE , 3262 : 192 – 196 .
  • Qu , J. Y. , Wilson , B. C. and Suria , D. 1999 . Concentration measurements of multiple analytes in human sera by near-infrared laser Raman spectroscopy . Appl. Optics , 38 ( 25 ) : 5491 – 5498 .
  • Petibois , C. , Rigalleau , V. , Melin , A. M. , Perromat , A. , Cazorla , G. , Gin , H. and Deleris , G. 1999 . Determination of glucose in dried serum samples by Fourier transform infrared spectroscopy . Clin. Chem. , 45 ( 9 ) : 1530 – 1535 .
  • Petrich , W. , Dolenko , B. , Früh , J. , Ganz , M. , Greger , H. , Jacob , S. , Keller , F. , Nikulin , A. , Otto , M. , Quarder , O. , Somorjai , R. , Staib , A. , Werner , G. and Wielinger , H. 2000 . Disease pattern recognition in infrared spectra of human sera using diabetes mellitus as an example . Appl. Opt. , 39 : 3372 – 3379 .
  • Petibois , C. , Melin , A. M. , Perromat , A. , Cazorla , G. , Gin , H. and Deleris , G. 2000 . Glucose and lactate concentration determination on single microsamples by Fourier-transform infrared spectroscopy . J. Lab. Clin. Med. , 135 ( 2 ) : 210 – 215 .
  • Shaw , R. A. and Mantsch , H. H. 2000 . Multianalyte serum assays from mid-IR spectra of dry films on glass slides . Appl. Spectrosc. , 54 : 885 – 889 .
  • Shaw , R. A. , Kotovich , S. , Leroux , M. and Mantsch , H. H. 1998 . Multianalyte serum analysis using mid-infrared spectroscopy . Ann. Clin. Biochem. , 35 : 624 – 632 .
  • Heise , H. M. , Marbach , R. , Koschinsky , Th. and Gries , F. A. 1994 . Multicomponent assay for blood substrates in human plasma by mid-infrared spectroscopy and its evaluation for clinical analysis . Appl. Spectrosc. , 48 : 85 – 95 .
  • Heise , H. M. , Marbach , R. , Bittner , A. and Koschinsky , Th. 1998 . Clinical Chemistry and Near-infrared spectroscopy: multicomponent assay for human plasma and its evaluation for the determination of blood substrates . J. Near Infrared Spectrosc. , 6 : 361 – 374 .
  • Eytan , O. , Sela , B.-A. and Katzir , A. 2000 . Fiber-optic evanescent wave spectroscopy and neural networks: application to chemical blood analysis . Appl. Opt. , 39 ( 19 ) : 3357 – 3360 .
  • Petibois , C. , Cazorla , G. , Cassaigne , H. and Deleris , G. 2001 . Plasma Proteins Contents determination by FT-IR spectroscopy . Clin. Chem. , 47 : 730 – 738 .
  • Petrich , W. , Dolenko , B. , Früh , J. , Greger , H. , Jacob , S. , Keller , F. , Nikulin , A. , Otto , M. , Quarder , O. , Somorjai , R. , Staib , A. , Werner , G. and Wielinger , H. Recognition of disease-specific patterns in FT-IR spectra of human sera , In: Reference [6] pp. 91–96
  • Petrich , W. , Dolenko , B. , Fink , D. J. , Früh , J. , Greger , H. , Jacob , S. , Keller , F. , Nikulin , A. , Otto , M. , Pessin-Minsley , M. S. , Quarder , O. , Somorjai , R. , Staib , A. , Thienel , U. , Werner , G. and Wielinger , H. 2001 . Disease pattern recognition in FT-IR spectra of human sera . Proc. SPIE , 4254 : 72 – 80 .
  • More precisely, the given numbers are Spearman's correlation coefficient based on rank-ordering
  • Schultz , C. P. , Liu , K.-Z. , Salamon , E. A. , Riese , K. T. and Mantsch , H. H. 1999 . Application of FT-IR microspectroscopy in diagnosing thyroid neoplasms . J. Mol. Struct. , 480/481 : 369 – 377 .
  • Buschmann , H. P.J. , van Aken , T. , Marple , E. T. , van der Laarse , A. , Bruschke , A. V.G. and Puppels , G. J. 1999 . “ In vivo Raman spectroscopy during laparoscopy ” . In Spectroscopy of biomedical molecules: new directions Edited by: Greve , J. , Puppels , G. J. and Otto , C. 483 – 484 . Dodrecht : Kluver Academic Publ .
  • Feld , M. S. , Manoharan , R. , Salenius , J. , Orenstein-Carndona , J. , Römer , T. J. , Brennan , J. F. III , Dasari , R. R. and Wang , Y. 1995 . Proc. SPIE , 2388 : 99 – 105 .
  • Wolthuis , R. , Bakker Schutt , T. G. , Caspers , P. J. , Buschman , H. P.J. , Römer , T. J. , Bruining , H. A. and Puppels , G. J. 1999 . “ Raman spectroscopic methods for in vitro and in vivo tissue characterization ” . In Fluorescent and Luminescent Probes , 2nd edition Academic Press . ISBN 0-12-447836-0
  • Lasch , P. , Wäsche , W. , McCarthy , W. J. , Müller , G. and Naumann , D. Imaging of human colon carcinoma thin sections by FT-IR microspectroscopy , 187 – 198 . In Reference [3]
  • Lasch , P. and Naumann , D. 1998 . FT-IR microspectroscopic imaging of human carcinoma thin sections based on pattern recognition techniques . Cell. Mol. Biol. , 44 ( 1 ) : 189 – 202 .
  • Wentrup-Byrne , E. , Rintoul , L. , Smith , J. L. and Fredericks , P. M. 1995 . Comparison of vibrational spectroscopic techniques for the characterization of human gallstones . Appl. Spectrosc. , 49 : 1028 – 1036 .
  • Manoharan , R. , Wang , Y. , Dasari , R. R. , Singer , S. , Rava , R. P. and Feld , M. S. 1995 . Ultraviolet Resonance Raman spectroscopy for detection of colon cancer . Lasers Life Sci. , 6 : 217 – 221 .
  • Krieg , P. , Lendl , B. , Vonach , R. and Kellner , R. 1996 . Determination of alpha-amylase activity using Fourier-transform infrared spectroscopy . Fresenius J. Anal. Chem. , 356 : 504 – 507 .
  • Schmitt , J. and Udelhoven , T. Use of artificial neural networks in biomedical diagnosis , 379 – 419 . In Reference [9]
  • Shim , M. G. , Wong Kee , L.-M. , Song , N. , Marcon , S. , Hassaram , B. C. and Wilson . Assessment of ex-vivo and in-vivo Near-Infrared Raman Spectroscopy for the Classification of Dyslasia within Barrett's esophagus , 114 – 119 . In Reference [6]
  • Chiriboga , L. , Yee , H. and Diem , M. 2000 . Infrared Spectroscopy of Human Cells and Tissue. Part VI: A comparative study of histopathology and infrared microspectroscopy of normal, cirrhotic, and cancerous liver tissue . Appl. Spectrosc. , 54 ( 1 ) : 1 – 8 .
  • Chiriboga , L. , Yee , H. and Diem , M. 2000 . Infrared spectroscopy of human cells and tissue. Part VII: FT-IR microspectroscopy of DNAse and RNAse-treated normal, cirrhotic, and neoplastic liver tissue . Appl. Spectrosc. , 54 ( 4 ) : 480 – 485 .
  • Volmer , M. , Bolck , A. , Wolters , B. G. , de Ruiter , A. J. , Doornbos , D. A. and van der Silk , W. 1993 . Partial least-squares regression for routine analysis of urinary calculus composition with Fourier transform infrared analysis . Clin. Chem. , 39 : 948 – 954 .
  • Kontonyannis , C. G. , Bourpopoulos , N. C. and Koutsoukos , P. G. 1997 . Urinary stone layer analysis of mineral components by Raman spectrsocopy, IR spectroscopy, and x-ray powder diffraction: a comparative study . Appl. Spectrosc. , 51 : 1205 – 1209 .
  • Goodacre , R. , Timmins , É.M. , Burton , R. , Kaderbhai , N. , Woodward , A. M. , Kell , D. B. and Rooney , P. J. 1998 . Rapid identification of urinary tract infection bacteria using hyperspectral, whole organism fingerprinting and artificial neural networks . Microbiology , 144 : 1157 – 1170 .
  • Rozelle , L. T. , Hallgren , L. J. , Bransford , J. E. and Koch , R. B. 1965 . The identification of major infrared absorbing components of human urine . Appl. Spectrosc. , 4 : 120 – 124 .
  • Dou , X. , Yamaguchi , Y. , Yamamoto , H. , Doi , S. and Ozaki , Y. 1996 . Quantitative analysis of metabolites in urine using a highly precise, compact near-infrared Raman spectrometer . Vib. Spectrosc. , 13 : 83 – 89 .
  • Dou , X. , Yamaguchi , Y. , Yamamoto , H. , Doi , S. and Ozaki , Y. 1997 . Quantitative analysis of metabolites in urine by Anti-Stokes Raman Spectroscopy . Biospectrosc. , 3 : 113 – 120 .
  • Heise , H. M. , Voigt , G. , Lampen , P. , Küpper , L , Rudloff , S. and Werner , G. 2001 . Multivariate calibration for the determination of analytes in urine using mid-infrared attenuated total reflection spectroscopy . Appl. Spectrosc. , 55 ( 4 ) : 434 – 443 .
  • Shaw , R. A. , Low Ying , S. , Leroux , M. and Mantsch , H. H. 2000 . Toward reagent-free clinical analysis: quantitation of urine urea, creatine, and total protein from the mid-infrared spectra of dried urine films . Clin.Chem. , 46 : 1493 – 1495 .
  • On the other hand, reference methods are per se determined by an independent validation which usually yield not as good a value as does the leave-one-out validation
  • Markus , A. P.J.A. , Swinkels , D. W. , Jakobs , B. S. , Wevers , R. A. , Trijbels , J. M.F. and Willems , H. L. 2001 . New technique for diagnosis and monitoring of alcaptonuria: quantification of homogentisic acid in urine with mid-infrared spectroscopy . Anal. Chim. Acta , 429 : 287 – 292 .
  • Naumann , D. FT-Infrared and FT-Raman spectroscopy in biomedical research , 323 – 378 . In Reference [9]
  • Mizuno , A. , Kitajima , H. , Kawauchi , K. , Maraishi , S. and Ozaki , Y. 1994 . Near infrared Fourier transform Raman spectroscopic study of human brain tissues and tumors . J. Raman Spectrosc. , 25 : 25 – 29 .
  • Levine , S. M. and Wetzel , D. L. 1998 . Chemical analysis of multiple sclerosis lesions by FT-IR microspectroscopy . Free Radical Biol. Med. , 25 ( 1 ) : 33 – 41 .
  • Lewis , E. N. , Kidder , L. H. , Levin , I. W. , Kalasinsky , V. F. , Hanig , J. P. and Lester , D. S. 1997 . Applications of Fourier Transform infrared imaging microscopy in neurotoxicity . Ann. NY. Acad. Sci. , 820 : 234 – 247 .
  • Lester , D. S. , Kidder , L. H. , Levin , I. W. and Lewis , E. N. 1998 . Infrared microscpectroscopic imaging of the cerebellum of normal and cytarabine treated rats . Cell. Mol. Biol. , 44 : 29 – 38 .
  • Kidder , L. H. , Colarusso , P. , Steward , S. A. , Levin , I. W. , Appel , N. M. , Lester , D. S. , Pentchev , P. G. and Lewis , E. N. 1999 . Infrared spectroscopic imaging of the biochemical modifications induced in the cerebellum of the Niemann-Pick typeC mouse . J. Biomed. Optics , 4 : 7 – 13 .
  • Schaeberle , M. D. , Levin , I. W. and Lewis , E. N. Biological vibrational spectroscopic imaging , 231 – 258 . in Reference [9]
  • Wetzel , D. L. and LeVine , S. M. Biological applications of infrared microspectroscopy , 101 – 142 . In Reference [9]
  • Sajid , J. , Elhaddasoui , A. and Turrell , S. 1997 . Fourier transform vibrational spectroscopic analysis of human cerebral tissue . J. Raman Spectrosc. , 28 : 165 – 9 .
  • Fabian , H. , Choo , L.-P. , Szendrei , G. I. , Jackson , M. , Halliday , W. C. , Otvoz , L. Jr. and Mantsch , H. H. 1993 . Infrared spectroscopic characterization of Alzheimer plaques . Appl. Spectrosc. , 47 : 1513 – 18 .
  • Pizzi , N. , Choo , L. P. , Mansfield , J. , Jackson , M. , Halliday , W. C. , Mantsch , H. H. and Somorja , R. L. 1995 . Neural network classification of infrared spectra of control and Alzheimer's diseased tissue . Artificial Intell. Med. , 7 : 67 – 79 .
  • Choo , J L.-P. , Mansfield , R. , Pizzi , N. , Somorjai , R. L. , Jackson , M. , Halliday , W. C. and Mantsch , H. H. 1995 . Infrared spectra of human central nervous system tissue: Diagnosis of Alzheimer's disease by multivariate analysis . Biospectrosc. , 1 : 141 – 148 .
  • Mahadevan-Jansen , A. , Mitchell , M. F. , Ramanujam , N. , Malpica , A. , Thomsen , S. , Utzinger , U. and Richards-Kortum , R. 1998 . Near Infrared Raman spectroscopy for in vitro detection of cervical precancers . Photochem. Photobiol. , 68 : 123 – 132 .
  • Mahadevan-Jansen , A. and Richards-Kortum , R. 1996 . Raman spectroscopy for the detection of cancers and precancers . J. Biomed. Optics , 1 : 31 – 70 .
  • Note that these values were improved to 88% and 92%, respectively, if the spectra underwent a patient-specific normalization prior to the analysis. However, this normalization would always require the second, colposcopically normal biopsy from each patient, which would diminish the benefits of a Raman-spectroscopic procedure
  • Mitchell , M. F. 1994 . Accuracy of colposcopy . Consult. Obstet. Gynecol. , 6 : 70
  • Chiriboga , L. , Xie , P. , Znang , W. and Diem , M. 1997 . Infrared spectroscopy of human tissue III: Spectral differences between squamous and columnar tissue and cells from the human cervix . Biospectrosc. , 3 : 253 – 256 .
  • Chiriboga , L. , Xie , P. , Yee , H. , Zarou , D. , Zakim , D. and Diem , M. 1998 . Infrared spectroscopy of human tissue IV: Detection of dysplastic and neoplastic changes of human cervical tissue via infrared microscopy . Cell. Mol. Biol. , 44 ( 1 ) : 219 – 230 .
  • Chiriboga , L. , Xie , P. , Yee , H. , Vigorita , V. , Zarou , D. , Zakim , D. and Diem , M. 1998 . Infrared spectroscopy of human tissue I: Differentiation and maturation of epithelial cells in the human cervix . Biospectrosc. , 4 : 47 – 53 .
  • Chiriboga , L. , Xie , P. , Vigorita , V. , Zarou , D. , Zakim , D. and Diem , M. 1998 . Infrared spectroscopy of human tissue II: A comparative study of spectra of biopsies of cervical squamous epithelium and of exfoliated cervical cells . Biospectrosc. , 4 : 55 – 59 .
  • Romeo , M. , Burden , F. , Quinn , M. , Wood , B. and McNaughton , D. 1998 . Infrared microscpectroscopy and artificial neural networks in the diagnosis of cervical cancer . Cell. Mol. Biol. , 44 ( 1 ) : 179 – 188 .
  • Shaw , R. A. , Leroux , M. , Paraskevas , M. , Guijon , F. B. , Kotowich , S. and Mantsch , H. H. Discrimination and quantitation using IR spectra: Novel methods for serum analysis and for cervical dysplasia screening , 42 – 50 . In: Reference [3]
  • McNaughton , D. , Hislop , T. , Quinn , M. A. , Romeo , M. and Wood , B. R. FTIR microspectroscopy for the detection of potential confounding variables in Pap smears , 445 – 446 . In Reference [2]
  • Wood , B. R. , Quinn , M. A. , Tait , B. , Ashdown , M. , Hislop , T. , Romeo , M. and McNaughton , D. 1998 . FTIR microspectroscopic study of cell types and potential confounding variables in screening for cervical malignancies . Biospectrosc. , 4 ( 2 ) : 75 – 91 .
  • Lowry , S. R. 1998 . The analysis of exfoliated cervical cells by infrared microscopy . Cell. Mol. Biol. , 44 ( 1 ) : 169 – 177 .
  • Cohenford , M. A. and Rigas , B. 1998 . Cytologically normal cells from neoplastic cervical samples display extensive structural abnormalities on IR spectroscopy: Implications for tumor biology . Proc. Natl. Acad. Sci. USA , 95 ( 26 ) : 15327 – 15332 .
  • Alfano , R. R. , Liu , C. H. , Sha , W. L. , Akins , D. L. , Cleary , J. , Prudente , R. and Cellmer , C. 1991 . Human Breast Tissues studies by IR Fourier transform Raman spectroscopy . Lasers Life Sci. , 4 : 23 – 28 .
  • Malins , D. C. , Polissar , N. L. , Nishikida , K. , Holmes , E. H. , Gardner , H. S. and Gunselman , S. J. 1995 . The etiology and prediction of breast cancer. Fourier transform infrared spectroscopy reveals progressive alterations in breast DNA leading to a cancer-like phenotype in a high proportion of normal women . Cancer , 75 : 503 – 517 .
  • Frank , C. J. , McCreery , R. L. and Redd , D. C.B. 1995 . Raman spectra of normal and diseased human breast tissues . Anal. Chem. , 67 : 777 – 783 .
  • Dukor , R. K. , Liebmann , M. N. and Johnson , B. L. 1998 . A new, non-destructive method for analysis of clinical samples with FT-IR microspectroscopy: Breast cancer tissue as an example . Cell. Mol. Biol. , 44 ( 1 ) : 211 – 218 .
  • Meurens , M. , Wallon , J. , Tong , J. , Noel , H. and Haot , J. 1996 . Breast cancer detection by Fourier transform infrared spectrometry . Vib. Spectrosc. , 10 : 341 – 346 .
  • Yazdi , Y. , Ramanujam , N. , Lotan , R. , Mitchell , M. F. , Hittelman , W. and Richards-Kortum , R. 1999 . Resonance Raman Spectroscopy at 257 nm Excitation of Normal and malignant Cultured Breast and cervical cells . Appl. Spectrosc. , 53 : 82 – 85 .
  • Fabian , H. , Wessel , R. , Jackson , M. , Schwartz , A. , Lasch , P. , Fichtner , I. , Mantsch , H. H. and Naumann , D. IR spectroscopy and IR microscopy of human breast tumors, xenografted breast tumors, and breast tumor cell lines , 13 – 23 . In Reference [3]
  • Kidder , L. H. , Haka , A. S. , Faustino , P. J. , Lester , D. S. , Levin , I. W. and Lewis , E. N. Infrared spectroscopic imaging as a tool for pathology , 178 – 186 . In Reference [3]
  • Jackson , M. , Kim , K. , Tetteh , J. , Mansfield , J. R. , Dolenko , B. , Somorjai , R. L. , Orr , F. W. , Watson , P. H. and Mantsch , H. H. Cancer diagnosis by infrared spectroscopy: methodogical aspects , 24 – 34 . In Reference [3]
  • Since all spectra originate from the same patient and have been preprocessed exactly the same way it is not too surprising that the classification yields an accuracy of 90% and above using leave-one-out and leave-five-out cross validation
  • Liu , K. Z. , Dembinski , T. C. and Mantsch , H. H. 1998 . Rapid determination of fetal lung maturity from infrared spectra of amniotic fluid . Am. J. Obstet. Gynecol. , 178 : 234 – 241 .
  • Liu , K. Z. and Mantsch , H. H. 1999 . Simultaneous quantitation from infrared spectra of glucose concentrations, lactate concentrations, and lecithin/shingomyelin ratios in amniotic fluid . Am. J. Obstet. Gynecol. , 180 : 696 – 702 .
  • Liu , K. Z. , Dembinski , T. C. and Mantsch , H. H. 1998 . Prediction of RDS from amniotic fluid analysis: a comparison of the prognostic value of TLC and infrared spectroscopy . Prenatal Diagnosis , 18 : 1267 – 1275 .
  • Schrader , B. , Keller , S. , Löchte , T. , Fendel , S. , Moore , D. S. , Simon , A. and Sawtzki , J. 1995 . NIR-FT Raman spectroscopy in medical diagnosis . J. Mol. Struct. , 348 : 293 – 296 .
  • Edwards , H. G.M. , Williams , A. C. and Barry , B. C. 1995 . Potential applications of FT-Raman spectroscopy for dermatological diagnosis . J. Mol. Struct. , 347 : 379 – 88 .
  • Gniadecka , M. , Wulf , H. C. , Nielsen , O. F. , Christensen , D. H. and Hercogova , J. 1997 . Distinctive molecular abnormalities in benign and malignant skin lesions: studies by Raman spectroscopy . Photochem. Photobiol. , 66 : 418 – 423 .
  • Gniadecka , M. , Wulf , H. C. , Nymark , N. , Mortensen , O. , Feurskov , N. and Christensen , D. H. 1997 . Diagnosis of basal cell carcinoma by Raman spectroscopy . J. Raman Spectrosc. , 28 : 125 – 130 .
  • Lucason , G. W. , Caspers , P. J. and Puppels , G. J. 2000 . Water content and water profiles in skin measured by FT-IR and Raman spectroscopy . Proc. SPIE , 4126 : 39 – 45 .
  • Khalil , O. S. 1999 . Spectroscopic and clinical aspects of non-invasive glucose measurements . Clin. Chem , 45 : 165 – 177 .

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.