Publication Cover
Journal of Environmental Science and Health, Part A
Toxic/Hazardous Substances and Environmental Engineering
Volume 36, 2001 - Issue 3
37
Views
2
CrossRef citations to date
0
Altmetric
Original Articles

CHARACTERIZATION OF MIXING PATTERNS IN A VENTILATED AIRSPACE WITH A MULTIPLE AIRFLOW REGIONS GAMMA MODEL

&
Pages 333-353 | Received 27 Mar 2000, Published online: 06 Feb 2007

REFERENCES

  • Liao , C. M. and Feddes , J. J. R. 1990 . Mathematical analysis of a lumped-parameter model for describingthe behavior of airborne dust in animal housing . Appl. Math. Modelling , 14 : 248 – 257 .
  • Liao , C. M. and Feddes , J. J. R. 1991 . Modelling and analysis of airborne dust removal from a ventilatedairspace . Canadian Agric. Engng , 33 : 355 – 361 .
  • Liao , C. M. and Feddes , J. J. R. 1992 . A lumped-parameter model for predicting airborne dust concentrationin a ventilated airspace . Trans. ASAE , 35 ( 6 ) : 1973 – 1978 .
  • Gao , W. and Feddes , J. J. R. 1993 . Using swine dust to verify a lumped-parameter model in a ventilatedenclosure . Canadian Agric. Engng , 35 : 67 – 73 .
  • Liao , C. M. and Bundy , D. S. 1995 . Quantification of ventilation on distribution of gaseous pollutantsemitted from stored swine manure . J. Environ. Sci. Health , B30 ( 6 ) : 859 – 893 .
  • Hoff , S. J. and Bundy , D. S. 1996 . Comparison of contaminant dispersion modeling approaches forswine housing . Trans. ASAE , 39 ( 3 ) : 1151 – 1157 .
  • Nauman , E. B. and Buffham , B. A. 1983 . Mixing in Continuous Flow Systems New York : Wiley .
  • Levenspiel , O. 1999 . Chemical ReactionEngineering New York : Wiley .
  • Barber , E. M. and Ogilvie , J. R. 1982 . Incomplete mixing in ventilated airspaces. Part I: Theoreticalconsiderations . Canadian Agric. Engng , 24 ( 1 ) : 25 – 29 .
  • Chen , Y. C. , Barber , E. M. , Zhang , Y. , Besant , R. W. and Sokhansanj , S. 1999 . Methods to measure dust production and deposition rates in buildings . J. Agric. Engng Res. , 72 : 329 – 340 .
  • Choi , H. L. , Albright , L. D. , Timmons , M. B. and Warhaft , Z. 1988 . An application of the k-epsilon turbulence model to predictair distribution in a slot-ventilated enclosure . Trans. ASAE , 31 ( 6 ) : 1804 – 1814 .
  • Hoff , S. J. , Janni , K. A. and Jacosbon , L. D. 1992 . Three-dimensional buoyant turbulent flows in a scaled model,slot-ventilated, livestock confinement facility . Trans. ASAE , 35 ( 2 ) : 671 – 686 .
  • Maghirang , R. G. and Manbeck , H. B. 1993 . Modeling particle transport in slot-inlet ventilated airspaces . Trans. ASAE , 36 ( 5 ) : 1449 – 1460 .
  • Liu , Q. , Hoff , S. J. , Maxwell , G. M. and Bundy , D. S. 1996 . Comparison of three k-epsilon turbulence models for predictingventilation air jets . Trans. ASAE , 39 ( 2 ) : 689 – 698 .
  • Liao , C. M. 1997 . Use of residence time distribution for evaluation of gaseouspollutant volatilization from stored swine manure . J. Environ. Sci. Health , B32 ( 1 ) : 127 – 145 .
  • Sandberg , M. 1983 . Ventilation efficiency as a guide to design . ASHRAE Trans. , 89 ( IIb ) : 455 – 479 .
  • Freeman , J. , Gale , R. and Sandberg , M. TheEfficiency of Ventilation in a Detached House . Proceedings 3rdAIC Conference . Sept 20–23 1982 , London, England. EnergyEfficient Domestic Ventilation Systems for Achieving Acceptable Indoor AirQuality , pp. 45 – 51 . Bracknell, , Berkshire, England : Air Infiltration Centre .
  • Skarret , E. and Mathisen , H. M. 1981 . International Symposium on Indoor Air Pollution, Health and EnergyConservation 102 – 110 . Mass : Amherst .
  • Cholette , A. and Cloutier , L. 1959 . Mixing efficiency determinations for continuous flow systems . The Canadian J. Chem. Engng , 37 : 105 – 112 .
  • Jennings , B. H. and Armstrong , J. A. 1971 . Ventilation theory and practice . ASHRAE Trans. , 77 ( I ) : 50 – 60 .
  • Buffham , B. A. and Gibilaro , L. G. 1968 . A generalization of the tanks-in-series mixing model . AIChE J. , 14 ( 5 ) : 805 – 806 .
  • Wadpole , R. E. and Myers , R. H. 1985 . Probability and Statistics for Engineersand Scientists , 4th Ed. New York : Macmillan .
  • Ahn , I. S. , Lion , L. W. and Shuler , M. L. 1999 . Validation of a hybrid two-site gamma model for naphthalenedesorption kinetics . Environ. Sci. Tech. , 33 : 3241 – 3248 .
  • Culver , T. B. , Hallisey , S. P. , Sahoo , D. , Deitsch , J. J. and Smith , J. A. 1997 . Modeling the desorption of organic contaminants from long-termcontaminated soil using distributed mass transfer rates . Environ. Sci. Tech. , 31 : 1581 – 1588 .
  • Grot , R. A. and Lagus , P. L. 1991 . Application of Tracer Gas Analysis toIndustrial Hygiene Investigations 1 – 21 . San Diego, CA : Lagus Applied Technology, Inc. .
  • Liao , C. M. , Wang , T. S. and Liu , C. M. 1991 . A lumped-parameter model describing the behavior of carbon dioxideconcentrations in a slot-ventilated airspace. Part II: Model verification . J. Soc. Agr. Structure, Japan , 22 ( 1 ) : 17 – 24 .

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.