0
Views
29
CrossRef citations to date
0
Altmetric
Original Article

Repeatability of the phenol‐red thread and tear thinning time tests for tear film function

, MSc MBCO FBDO & , PhD FAAO
Pages 64-68 | Received 23 Apr 2009, Accepted 29 Nov 1993, Published online: 15 Apr 2021

References

  • Golding TR. Evaluation of tear film impairment in dry eye and hydrophilic contact lens wear. PhD thesis, University of Melbourne 1992.
  • Hamano H., Hori M., Hamano T., Mitsunaga S., Maeshima J, Kojima S., Kawabe H., Hamano T.. A new method for measuring tears. CLAOJ 1983; 9: 281–289.
  • Hamano T., Mitsunuga S., Kotani S., Hamano T., Hamano K., Hamano H., Sakamoto R., Tamura H.. Tear volume in relation to contact lens wear and age. CLAOJ 1990; 16: 57–61.
  • Clinch TE, Dominick AB, Felberg NT, Laibson PR. Schirmer's test, a closer look. Arch Ophthalmol 1983; 101: 1383–1386.
  • Patel S., Murray D., Mckenzie A., Shearer DS, Mcgrath BD. Effect of fluorescein on the tear film break‐up time and TTT. Am J Optom Physiol Opt 1985; 62: 188–200.
  • Patel S., Bevan R. Farrell JC. Diurnal variation in pre‐corneal tear film stability. Am J Optom Physiol Opt 1988; 65: 151–154.
  • Mengher LS, Bron AJ, Tonge SR, Gilbert DJ. A non‐invasive instrument for clinical assessment of the pre‐corneal tear film stability. Curr Eye Res 1985; 4: 1–7.
  • Cho P., Brown B., Chan I., Conway R., Yap M.. Reliability of the tear breakup time technique of assessing tear stability and the locations of the tear break‐up in Hong Kong Chinese. Optom Vis Sci 1992; 69: 879–885.
  • Patel S. Farrell JC. Age‐related changes in precorneal tear film stability. Optom Vis Sci 1989; 66: 175–178.
  • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 307–310.
  • Brown B., Cho P.. Non‐invasive tear break‐up time within and between subjects. Invest Ophthalmol Vis Sci 1993; 34: 14–70.
  • Bennett ES, Henry VA, Sakamoto R., Paragina S., Morgan BW, Nelson JM. Phenol red thread test. Contact Lens Spectrum 1992; 7: 31–32.
  • Sakamoto R., Bennett ES, Henry VL. The phenol red thread test. A cross‐cultural study. Invest Ophthalmol Vis Sci 1993; 34: 3510–3514.
  • Reeves BC, Wood JM, Hill AR. Vistech VCTS 6500 charts – within and between‐session reliability. Optom Vis Sci 1991; 68: 728–737.
  • Brown B., Yap MKH. Variability in repeated contrast sensitivity measures: implications for the individual patient. Clin Exp Optom 1991; 74: 151–155.
  • Brown B., Lovie‐kitchin JE. Repeated visual acuity measurement: establishing the patient's own criterion for change. Optom Vis Sci 1993; 70: 45–53.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.