References
- O’Higgins EA, Kirschen RH, Lee RT: The influence of maxillary incisor inclination on arch length.Br J Orthod., 1999; 26: 97–102.
- Gioka C, Eliades T: Materials‐induced variations in the torque expression of preadjusted appliances.Am J Orthod 2004; 125: 323–28.
- Fischer‐Brandies H, Orthuber W, Es‐Souni M, Meyer S: Torque transmission between square wire and bracket as a function of measurement, form and hardness parameters.J Orofac Orthop; 2000; 61: 258–64.
- Miethke RR, Melsen B: Effect of variation in tooth morphology and bracket position on first and third order correction with preadjusted appliances. Am J Orthod; 1999; 116: 329–35.
- Sebanc J, Brantley WA, Pincsak JJ, Conover JP: Variability of effective torque as a function of edge bevel on orthodontic arch wires. Am J Orthod; 1984; 86: 43–51.
- Meling TR, Odegaard J, Meling E: A theoretical evaluation of the influence of variation in bracket slot height and wire rounding on the amount of torsional play between bracket and wire. Kieferorthop Mitt 1993; 7: 41–48.
- Meling TR, Odegaard J: On the mechanical properties of square and rectangular stainless steel wires tested in torsion. Am J Orthod 1997; 111: 310–20.
- Kusy RP, Whitley JQ: Assessment of second‐order clearences between orthodontic archwires and bracket slot via the critical contact angle for binding. Angle Orthod 1999; 69: 71–80.
- Kusy RP: ‘Two’ much of a good thing? Then let's pick one slot size and make it metric. Am J Orthod 2002; 121: 337–38.
- Peck S: Orthodontic slot size: it's time to retool. Angle Orthod 2001; 71: 329–30.
- Siatkowski RE: Loss of anterior torque control due to variations in bracket slot and archwire dimensions. J Clin Orthod 1999; 33: 508–10.
- Cash AC, Good SA, Curtis RV, McDonald F: An evaluation of slot size in orthodontic brackets‐are standards as expected? Angle Orthod 2004; 74: 450–53.
- Morina E, Eliades T, Pandis N, Jäger A, Bourauel C: Torque expression of self‐ligating brackets compared with conventional metallic, ceramic, and plastic brackets. Eur J Orthod 2008; 30: 233–38.
- Meling TR, Odegaard J, Segner D: On bracket slot height: a methodologic study. Am J Orthod 1998; 113: 387–93.
- Badawi HM, Toogood RW, Carey J, Heo G, Major PW: Torque expression of self ligating brackets. Am J Orthod 2008; 133: 721–28.
- Sernetz F: Qualität und Normung orthodontischer Produkte. Kieferorthop Mitt 1993; 7: 13–26.
- Sernetz F: Normung kieferorthopädischer Produkte‐Macht das Sinn? J Orofac Orthop 2005; 66: 307–18.
- Deutsches Institut für Normung e.V. DIN 13971: 1998‐01 Zahnheilkunde‐ Kieferorthopädische Drähte.
- Deutsches Institut für Normung e.V. DIN 13971‐2: 2000‐01 Kieferorthopädische Produkte.
- Rauch DE: Torque and its application to orthodontics Am J Orthod 1959; 45: 817–30.