833
Views
44
CrossRef citations to date
0
Altmetric
Review

HPLC-MS/MS in drug metabolism and pharmacokinetic screening

Pages 93-101 | Published online: 21 Dec 2007

Bibliography

  • White RE. High-throughput screening in drug metabolism and pharmacokinetic support of drug discovery. Ann Rev Pharmacol Toxicol 2000;40:133-57
  • Hsieh Y, Korfmacher WA. Increasing speed and throughput when using HPLC-MS/MS systems for drug metabolism and pharmacokinetic screening. Curr Drug Metab 2006;7(5):479-89
  • Hsieh Y, Fukuda E, Wingate J, et al. Fast mass spectrometry-based methodologies for pharmaceutical analyses. Comb Chem High Throughput Screen 2006;9(1):3-8
  • Korfmacher WA. Principles and applications of LC-MS in new drug discovery. Drug Discov Today 2005;10(20):1357-67
  • Nissen WMA. Editor. The Encyclopedia of Mass Spectrometry. (Volume 8) Elsevier Ltd. 2006
  • Masuda Y, Kanayama N, Manita S, et al. Development and validation of bioanalytical methods for Imidafenacin (KRP-197/ONO-8025) and its metabolites in human plasma by liquid chromatography-tandem mass spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci 2007;853(1-2):70-9
  • Hsieh Y, Duncan CJ, Lee S, et al. Comparison of fast liquid chromatography/tandem mass spectrometric methods for simultaneous determination of cladribine and clofarabine in mouse plasma. J Pharm Biomed Anal 2007;44(2):492-7
  • Shou WZ, Jiang X, Naidong W. Development and validation of a high-sensitivity liquid chromatography/tandem mass spectrometry (LC/MS/MS) method with chemical derivatization for the determination of ethinyl estradiol in human plasma. Biomed Chromatogr 2004;18(7):414-21
  • Hsieh Y, Chintala M, Mei H, et al. Quantitative screening and matrix effect studies of drug discovery compounds in monkey plasma using fast-gradient liquid chromatography/tandem mass spectrometry. Rapid Commun Mass Spectrom 2001;15(24):2481-7
  • Hsieh Y, Brisson JM, Wang G, et al. Simultaneous fast HPLC-MS/MS analysis of drug candidates and hydroxyl metabolites in plasma. J Pharm Biomed Anal 2003;33(2):251-61
  • Borges V, Yang E, Dunn J, et al. High-throughput liquid chromatography-tandem mass spectrometry determination of bupropion and its metabolites in human, mouse and rat plasma using a monolithic column. J Chromatogr B Analyt Technol Biomed Life Sci 2004;804(2):277-87
  • Hsieh Y, Wang G, Wang Y, et al. Direct plasma analysis of drug compounds using monolithic column liquid chromatography and tandem mass spectrometry. Anal Chem 2003;75(8):1812-18
  • Peng SX, Barbone AG, Ritchie DM. High-throughput cytochrome p450 inhibition assays by ultrafast gradient liquid chromatography with tandem mass spectrometry using monolithic columns. Rapid Commun Mass Spectrom 2003;17(6):509-18
  • Hsieh Y, Wang G, Wang Y, et al. Simultaneous determination of a drug candidate and its metabolite in rat plasma samples using ultrafast monolithic column high-performance liquid chromatography/tandem mass spectrometry. Rapid Commun Mass Spectrom 2002;16(10):944-50
  • Wu JT, Zeng H, Deng Y, et al. High-speed liquid chromatography/tandem mass spectrometry using a monolithic column for high-throughput bioanalysis. Rapid Commun Mass Spectrom 2001;15(13):1113-19
  • Volmer DA, Brombacher S, Whitehead B. Studies on azaspiracid biotoxins. I. Ultrafast high-resolution liquid chromatography/mass spectrometry separations using monolithic columns. Rapid Commun Mass Spectrom 2002;16(24):2298-305
  • Hsieh Y, Merkle K, Wang G. Zirconia-based column high-performance liquid chromatography/atmospheric pressure photoionization tandem mass spectrometric analyses of drug molecules in rat plasma. Rapid Commun Mass Spectrom 2003;7(15):1775-80
  • Wang H, Edom RW, Kumar S, et al. Separation and quantification of two diastereomers of a Drug Candidate in rat plasma by ultra-high pressure liquid chromatography/mass spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci 2007;854(1-2):26-34
  • Li KY, Zhou YG, Ren HY, et al. Ultra-performance liquid chromatography-tandem mass spectrometry for the determination of atypical antipsychotics and some metabolites in in vitro samples. J Chromatogr B Analyt Technol Biomed Life Sci 2007;850(1-2):581-5
  • Ma Y, Qin F, Sun X, et al. Determination and pharmacokinetic study of amlodipine in human plasma by ultra performance liquid chromatography-electrospray ionization mass spectrometry. J Pharm Biomed Anal 2007;43(4):1540-5
  • O'Connor D, Mortishire-Smith R, Morrison D, et al. Ultra-performance liquid chromatography coupled to time-of-flight mass spectrometry for robust, high-throughput quantitative analysis of an automated metabolic stability assay, with simultaneous determination of metabolic data. Rapid Commun Mass Spectrom 2006;20(5):851-7
  • Wang G, Hsieh Y, Cui X, et al. Ultra-performance liquid chromatography/tandem mass spectrometric determination of testosterone and its metabolites in in vitro samples. Rapid Commun Mass Spectrom 2006;20(14):2215-21
  • Hsieh Y, Duncan CJ, Brisson JM. Fused-core silica column high-performance liquid chromatography/tandem mass spectrometric determination of rimonabant in mouse plasma. Anal Chem 2007;79(15):5668-73
  • Stanley SM, Wee WK, Lim BH, et al. Direct-injection screening for acidic drugs in plasma and neutral drugs in equine urine by differential-gradient LC-LC coupled MS/MS. J Chromatogr B Analyt Technol Biomed Life Sci 2007;848(2):292-302
  • Zang X, Luo R, Song N, et al. A novel on-line solid-phase extraction approach integrated with a monolithic column and tandem mass spectrometry for direct plasma analysis of multiple drugs and metabolites. Rapid Commun Mass Spectrom 2005;19(22):3259-68
  • Xue YJ, Turner KC, Meeker JB, et al. Quantitative determination of pioglitazone in human serum by direct-injection high-performance liquid chromatography mass spectrometry and its application to a bioequivalence study. J Chromatogr B Analyt Technol Biomed Life Sci 2003;795(2):215-26
  • Kollroser M, Schober C. Direct-injection high performance liquid chromatography ion trap mass spectrometry for the quantitative determination of olanzapine, clozapine and N-desmethylclozapine in human plasma. Rapid Commun Mass Spectrom 2002;16(13):1266-72
  • Hsieh Y, Brisson JM, Ng K, et al. Direct simultaneous determination of drug discovery compounds in monkey plasma using mixed-function column liquid chromatography/tandem mass spectrometry. J Pharm Biomed Anal 2002;27(1-2):285-93
  • Hsieh Y, Brisson JM, Ng K, et al. Direct simultaneous analysis of plasma samples for a drug discovery compound and its hydroxyl metabolite using mixed-function column liquid chromatography-tandem mass spectrometry. Analyst 2001;126(12):2139-43
  • Wang G, Hsieh Y, Lau Y, et al. Semi-automated determination of plasma stability of drug discovery compounds using liquid chromatography-tandem mass spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci 2002;780(2):451-7
  • Korfmacher WA, Veals J, Dunn-Meynell K, et al. Demonstration of the capabilities of a parallel high performance liquid chromatography tandem mass spectrometry system for use in the analysis of drug discovery plasma samples, Rapid Commun Mass Spectrom 1999;13(20):1991-8
  • Jemal M. Increased throughput in quantitative bioanalysis using parallel-column liquid chromatography with mass spectrometric detection. Rapid Commun Mass Spectrom 2001;15(12):994-9
  • Van Pelt CK, Corso TN, Schultz GA, et al. A four-column parallel chromatography system for isocratic or gradient LC/MS analyses. Anal Chem 2001;73(3):582-8
  • Lindqvist A, Hilke S, Skoglund E, et al. Generic three-column parallel LC-MS/MS system for high-throughput in vitro screens. J Chromatogr A 2004;1058(1-2):121-6
  • Briem S, Pettersson B, Skoglund E. Description and validation of a four-channel staggered LC-MS/MS system for high-throughput in vitro screens. Anal Chem 2005;77(6):1905-10
  • Cai Y, Kingery D, McConnell O, et al. Advantages of atmospheric pressure photoionization mass spectrometry in support of drug discovery. Rapid Commun Mass Spectrom 2005;19(12):1717-24
  • Hsieh Y, Merkle K, Wang G, et al. High-performance liquid chromatography-atmospheric pressure photoionization/tandem mass spectrometric analysis for small molecules in plasma. Anal Chem 2003;75(13):3122-7
  • Yang C, Henion J. Atmospheric pressure photoionization liquid chromatographic-mass spectrometric determination of idoxifene and its metabolites in human plasma. J Chromatogr A 2002;970(1-2):155-65
  • Cai SS, Hanold KA, Syage JA. Comparison of atmospheric pressure photoionization and atmospheric pressure chemical ionization for normal-phase LC/MS chiral analysis of pharmaceuticals. Anal Chem 2007;79(6):2491-8
  • Bos SJ, Van Leeuwen SM, Karst U. From fundamentals to applications: recent developments in atmospheric pressure photoionization mass spectrometry. Anal Bioanal Chem 2006;384(1):85-99
  • Gallagher RT, Balogh MP, Davey P, et al. Combined electrospray ionization-atmospheric pressure chemical ionization source for use in high-throughput LC-MS applications. Anal Chem 2003;75(4):973-7
  • Short LC, Hanold KA, Cai SS, et al. Electrospray ionization/atmospheric pressure photoionization multimode source for low-flow liquid chromatography/mass spectrometric analysis. Rapid Commun Mass Spectrom 2007;21(10):1561-6
  • Hsieh Y, Chen J. Simultaneous determination of nicotinic acid and its metabolites using hydrophilic interaction chromatography with tandem mass spectrometry. Rapid Commun Mass Spectrom 2005;19(21):3031-6
  • Martens-Lobenhoffer J, Postel S, et al. Determination of ornithine in human plasma by hydrophilic interaction chromatography-tandem mass spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci 2007;855(2):271-5
  • Xu RN, Fan L, Rieser MJ, et al. Recent advances in high-throughput quantitative bioanalysis by LC-MS/MS. J Pharm Biomed Anal 2007;44(2):342-55
  • Jemal M, Xia YQ. LC-MS development strategies for quantitative bioanalysis. Curr Drug Metab 2006;7(5):491-502
  • Ji HY, Jeong DW, Kim YH, et al. Hydrophilic interaction liquid chromatography-tandem mass spectrometry for the determination of levofloxacin in human plasma. J Pharm Biomed Anal 2006;41(2):622-7
  • Hsieh Y, Duncan CJ, Brisson JM. Porous graphitic carbon chromatography/tandem mass spectrometric determination of cytarabine in mouse plasma. Rapid Commun Mass Spectrom 2007;21(5):629-34
  • Xia YQ, Jemal M, Zheng N, et al. Utility of porous graphitic carbon stationary phase in quantitative liquid chromatography/tandem mass spectrometry bioanalysis: quantitation of diastereomers in plasma. Rapid Commun Mass Spectrom 2006;20(12):1831-7
  • Hsieh Y, Duncan CJ. An ion-pairing liquid chromatography/tandem mass spectrometric method for the determination of cytarabine in mouse plasma. Rapid Commun Mass Spectrom 2007;21(4):573-8
  • Gao S, Bhoopathy S, Zhang ZP, et al. Evaluation of volatile ion-pair reagents for the liquid chromatography-mass spectrometry analysis of polar compounds and its application to the determination of methadone in human plasma. J Pharm Biomed Anal 2006;40(3):679-88
  • Hsieh Y, Duncan CJ, Liu M. A mixed-mode liquid chromatography-tandem mass spectrometric method for the determination of cytarabine in mouse plasma. J Chromatogr B Analyt Technol Biomed Life Sci 2007;854(1-2):8-12
  • Chen J, Korfmacher WA, Hsieh Y. Chiral liquid chromatography-tandem mass spectrometric methods for stereoisomeric pharmaceutical determinations. J Chromatogr B Analyt Technol Biomed Life Sci 2005;820(1):1-8
  • Kelly T, Doble P, Dawson M. Chiral analysis of methadone and its major metabolites (EDDP and EMDP) by liquid chromatography-mass spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci 2005;814(2):315-23
  • Desai MJ, Armstrong DW. Transforming chiral liquid chromatography methodologies into more sensitive liquid chromatography–electrospray ionization mass spectrometry without losing enantioselectivity. J Chromatogr A 2004;1035(2):203-10
  • Ramos L, Bakhtiar R, Majumdar T, et al. Liquid chromatography/atmospheric pressure chemical ionization tandem mass spectrometry enantiomeric separation of dl-threo-methylphenidate, (Ritalin) using a macrocyclic antibiotic as the chiral selector. Rapid Commun Mass Spectrom 1999;13(20):2054-62
  • Nikolai LN, McClure EL, Macleod SL, et al. Stereoisomer quantification of the beta-blocker drugs atenolol, metoprolol, and propranolol in wastewaters by chiral high-performance liquid chromatography-tandem mass spectrometry. J Chromatogr A 2006;1131(1-2):103-9
  • De La Puente ML. Highly sensitive and rapid normal-phase chiral screen using high-performance liquid chromatography-atmospheric pressure ionization tandem mass spectrometry (HPLC/MS). J Chromatogr A 2004;1055(1-2):55-62
  • Heinemann U, Blaschke G, Knebel N. Simultaneous enantioselective separation of azelastine and three of its metabolites for the investigation of the enantiomeric metabolism in rats. I. Liquid chromatography-ionspray tandem mass spectrometry and electrokinetic capillary chromatography. J Chromatogr B Analyt Technol Biomed Life Sci 2003;793(2):389-404
  • Goda R, Murayama N, Fujimaki Y, et al. Simple and sensitive liquid chromatography-tandem mass spectrometry method for determination of the S(+)- and R(-)-enantiomers of baclofen in human plasma and cerebrospinal fluid. J Chromatogr B Analyt Technol Biomed Life Sci 2004;801(2):257-64
  • Wu ST, Xing J, Apedo A, et al. High-throughput chiral analysis of albuterol enantiomers in dog plasma using on-line sample extraction/polar organic mode chiral liquid chromatography with tandem mass spectrometric detection. Rapid Commun Mass Spectrom 2004;18(21):2531-6
  • Korfmacher W. Using mass spectrometry for drug metabolism studies. Chapter 9, CRC Press. 2005
  • Evans DC, Baillie TA. Minimizing the potential for metabolic activation as an integral part of drug design. Curr Opin Drug Discov Devel 2005;8(1):44-50
  • Anari MR, Baillie TA. Bridging cheminformatic metabolite prediction and tandem mass spectrometry. Drug Discov Today 2005;10(10):711-17
  • Ma S, Subramanian R. Detecting and characterizing reactive metabolites by liquid chromatography/tandem mass spectrometry. J Mass Spectrom 2006;41(9):1121-39
  • Nassar AE, Lee DY. Novel approach to performing metabolite identification in drug metabolism. J Chromatogr Sci 2007;45(3):113-19
  • Li F, Hsieh Y, Duncan C, et al. Higher-throughput metabolite profiling of lead compounds in plasma samples using ultra performance liquid chromatography/quadrupole-linear ion trap mass spectrometric methods. 2007; in preparation
  • Li AC, Gohdes MA, Shou WZ. ‘N-in-one’ strategy for metabolite identification using a liquid chromatography/hybrid triple quadrupole linear ion trap instrument using multiple dependent product ion scans triggered with full mass scan. Rapid Commun Mass Spectrom 2007;21(8):1421-30
  • Peterman SM, Duczak N Jr, Kalgutkar AS, et al. Application of a linear ion trap/orbitrap mass spectrometer in metabolite characterization studies: examination of the human liver microsomal metabolism of the non-tricyclic anti-depressant nefazodone using data-dependent accurate mass measurements. J Am Soc Mass Spectrom 2006;17(3):363-75
  • Shou WZ, Magis L, Li AC, et al. A novel approach to perform metabolite screening during the quantitative LC-MS/MS analyses of in vitro metabolic stability samples using a hybrid triple-quadrupole linear ion trap mass spectrometer. J Mass Spectrom 2005;40(10):1347-56
  • Mei H, Hsieh Y, Nardo C, et al. Investigation of matrix effects in bioanalytical high-performance liquid chromatography/tandem mass spectrometric assays: application to drug discovery. Rapid Commun Mass Spectrom 2003;17(1):97-103
  • Chen J, Hsieh Y, Cook J, et al. Supercritical fluid chromatography-tandem mass spectrometry for the enantioselective determination of propranolol and pindolol in mouse blood by serial sampling. Anal Chem 2006;78(4):1212-17
  • Bakhtiar R, Majumdar TK. Tracking problems and possible solutions in the quantitative determination of small molecule drugs and metabolites in biological fluids using liquid chromatography-mass spectrometry. J Pharmacol Toxicol Methods 2007;55(3):262-78
  • De Nardi C, Bonelli F. Moving from fast to ballistic gradient in liquid chromatography/tandem mass spectrometry pharmaceutical bioanalysis: matrix effect and chromatographic evaluations. Rapid Commun Mass Spectrom 2006;20(18):2709-16
  • Matuszewski BK, Constanzer ML, Chavez-Eng CM. Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS/MS. Anal Chem 2003;75(13):3019-30

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.