22
Views
3
CrossRef citations to date
0
Altmetric
Case Report

Complications of fetal scalp electrode placement: a case report, literature review and summary of case reports

, &
Pages 113-120 | Published online: 10 Jan 2014

References

  • Paul RH, Hon EH. A clinical fetal monitor. Obstet. Gynecol. 35, 161–169 (1970).
  • Paul RH, Hon EH. Clinical fetal monitoring. A survey of current usage. Obstet. Gynecol. 37, 779–784 (1971).
  • Paul RH, Hon EH. Clinical fetal monitoring. IV. Experience with a spiral electrode. Obstet. Gynecol. 41, 777–780 (1973).
  • Cordero L, Anderson CW, Zuspan FP. Scalp abscess: a benign and infrequent complication of fetal monitoring. Am. J. Obstet. Gynecol. 146, 126–130 (1983).
  • Okada DM, Chow AW, Bruce VT. Neonatal scalp abscess and fetal monitoring: factors associated with infection. Am. J. Obstet. Gynecol. 129, 185–189 (1977).
  • Ashkenazi S, Metzker A, Merlob P, Ovadia J, Reisner SH. Scalp changes after fetal monitoring. Arch. Dis. Child. 60, 267–269 (1985).
  • Wagener MM, Rycheck RR, Yee RB, McVay JF, Buffenmyer CL, Harger JH. Septic dermatitis of the neonatal scalp and maternal endomyometritis with intrapartum internal fetal monitoring. Pediatrics 74, 81–85 (1984).
  • Scanlon JW, Walkley EI. Neonatal blood loss as a complication of fetal monitoring. Pediatrics 50, 934–936 (1972).
  • Duenhoelter JH. Survival of twins after acute fetal hemorrhage from ruptured vasa previa. Obstet. Gynecol. 73, 866–867 (1989).
  • Freedman RM, Baltimore R. Fatal Streptococcus viridans septicemia and meningitis: relationship to fetal scalp electrode monitoring. J. Perinatol. 10, 272–274 (1990).
  • Hohenauer L, Wilk F. [Severe infections in the newborn after direct cardiototography during delivery]. Z. Geburtshilfe Perinatol. 181, 55–58 (1977).
  • Jonkhoff-Slok TW, Weyerman ME. Scalp electrode associated neonatal Escherichia coli meningitis – a case report. J. Perinat. Med. 19, 217–219 (1991).
  • Kaye EM, Dooling EC. Neonatal herpes simplex meningoencephalitis associated with fetal monitor scalp electrodes. Neurology 31, 1045–1047 (1981).
  • Sauter M, Stoll W, Fricker HS, Wintsch K. [Fetal scalp phlegmon with septicemia and meningitis caused by group A hemolytic Streptococcus after internal fetal monitoring]. Gynakol. Rundsch. 20(Suppl. 1), 106–107 (1980).
  • Sola A, Bednarek FJ, Davidson R, Griffin BE. Meningitis, ventriculitis, and hydrocephalus: a complication of fetal monitoring. Obstet. Gynecol. 56, 663–665 (1980).
  • Turbeville DF, McCaffree MA. Fetal scalp electrode complications: cerebrospinal fluid leak. Obstet. Gynecol. 54, 469–470 (1979).
  • Goldkrand JW. Intrapartum inoculation of herpes simplex virus by fetal scalp electrode. Obstet. Gynecol. 59, 263–265 (1982).
  • Parvey LS, Ch’ien LT. Neonatal herpes simplex virus infection introduced by fetal-monitor scalp electrodes. Pediatrics 65, 1150–1153 (1980).
  • Amann ST, Fagnant RJ, Chartrand SA, Monif GR. Herpes simplex infection associated with short-term use of a fetal scalp electrode. A case report. J. Reprod. Med. 37, 372–374 (1992).
  • Driscoll DJ, Raab K. Herpes scalp infection associated with fetal electrode placement. Wis. Med. J. 75, 9–10 (1976).
  • Golden SM, Merenstein GB, Todd WA, Hill JM. Disseminated herpes simplex neonatorum: a complication of fetal monitoring. Am. J. Obstet. Gynecol. 129, 917–918 (1977).
  • Guill MA, Aton JK, Rogers RB. Neonatal herpes simplex associated with fetal scalp monitor. J. Am. Acad. Dermatol. 7, 408–409 (1982).
  • Katz M, Greco MA, Antony L, Young BK. Neonatal herpesvirus sepsis following internal monitoring. Int. J. Gynaecol. Obstet. 17, 631–633 (1980).
  • Adams G, Puroth D, Bada H. Neonatal infection by herpesvirus hominis type 2: a complication of intrapartum fetal monitoring. Pediatr. Res. 9, 377 (1975).
  • Goodlin RC, Harrod JR. Complications of fetal spiral electrodes. Lancet 1, 559 (1973).
  • Nieburg P, Gross SJ. Cerebrospinal fluid leak in a neonate associated with fetal scalp electrode monitoring. Am. J. Obstet. Gynecol. 147, 839–840 (1983).
  • Sharp DS, Couriel JM. Penetration of the subarachnoid space by fetal scalp electrode. Br. Med. J. (Clin. Res. Ed.) 291, 1169 (1985).
  • Sorokin Y, Weintraub Z, Rothschild A, Abramovici H, Iancu TC. Cerebrospinal fluid leak in the neonate – complication of fetal scalp electrode monitoring. Case report and review of the literature. Isr. J. Med. Sci. 26, 633–635 (1990).
  • Onyeama CO, Srinivasan H, Lotke M, Vickers DL. Subgaleal abscess and E. coli septicemia following scalp electrode in a preterm newborn: a case report. J. Matern. Fetal Neonatal Med. 22, 1201–1203 (2009).
  • Thadepalli H, Rambhatla K, Maidman JE, Arce JJ, Davidson EC Jr. Gonococcal sepsis secondary to fetal monitoring. Am. J. Obstet. Gynecol. 126, 510–512 (1976).
  • Overturf GD, Balfour G. Osteomyelitis and sepsis: severe complications of fetal monitoring. Pediatrics 55, 244–247 (1975).
  • Brook I. Osteomyelitis and bacteremia caused by Bacteroides fragilis: a complication of fetal monitoring. Clin. Pediatr. (Phila.) 19, 639–640 (1980).
  • McGregor JA, McFarren T. Neonatal cranial osteomyelitis: a complication of fetal monitoring. Obstet. Gynecol. 73, 490–492 (1989).
  • Yasunaga S. Complications of fetal monitoring: scalp abscess and osteomyelitis. IMJ III Med. J. 150, 41–43 (1976).
  • Handrick W, Huckel D, Spencker FB, Kuhnert C. [Infected scalp hematoma]. Zentralbl. Gynakol. 105, 1011–1013 (1983).
  • Siddiqi SF, Taylor PM. Necrotizing fasciitis of the scalp. A complication of fetal monitoring. Am. J. Dis. Child. 136, 226–228 (1982).
  • Hegde HR. Infected cephalhematoma associated with placement of scalp electrode. Can. Med. Assoc. J. 19, 122, 876–878 (1980).
  • Lauer AK, Rimmer SO. Eyelid laceration in a neonate by fetal monitoring spiral electrode. Am. J. Ophthalmol. 125, 715–717 (1998).
  • Miyashiro MJ, Mintz-Hittner HA. Penetrating ocular injury with a fetal scalp monitoring spiral electrode. Am. J. Ophthalmol. 128, 526–528 (1999).
  • Thomas G, Blackwell RJ. A hazard associated with the use of spiral fetal scalp electrodes. Am. J. Obstet. Gynecol. 121, 1118–1119 (1975).
  • Davey C, Moore AM. Necrotizing fasciitis of the scalp in a newborn. Obstet. Gynecol. 107, 461–463 (2006).
  • Koot RW, Reedijk B, Tan WF, De Sonnaville-De Roy Van Zuide. Neonatal brain abscess: complication of fetal monitoring. Obstet. Gynecol. 93, 857 (1999).
  • Freud E, Orvieto R, Merlob P. Neonatal labioperineal tear from fetal scalp electrode insertion. A case report. J. Reprod. Med. 38, 647–649 (1993).
  • Fernandez CM. Complications of fetal scalp electrodes: a case report. Am. J. Obstet. Gynecol. 145, 891 (1983).
  • Thoulon JM, Gonnet C. [Accidents that can occur during fetal direct electro-cardiographic recording. Concerning a fracture of the scalp electrode]. J. Gynecol. Obstet. Biol. Reprod. (Paris) 7, 1257–1260 (1978).
  • Akhter MS. An unusual complication of intrapartum fetal monitoring. Am. J. Obstet. Gynecol. 124, 657–658 (1976).
  • Turbeville DF, Heath RE Jr, Bowen FW Jr, Killam AP. Complications of fetal scalp electrodes: a case report. Am. J. Obstet. Gynecol. 122, 530–531 (1975).
  • Alfirevic Z, Devane D, Gyte GM. Continuous cardiotocography (CTG) as a form of electronic fetal monitoring (EFM) for fetal assessment during labour. Cochrane Database Syst. Rev. 19, CD006066 (2006).
  • Haverkamp AD, Orleans M. An assessment of electronic fetal monitoring. Women Health 7, 115–134 (1982).
  • Devane D, Lalor JG, Daly S, McGuire W, Smith V. Cardiotocography versus intermittent auscultation of fetal heart on admission to labour ward for assessment of fetal wellbeing. Cochrane Database Syst. Rev. 2, CD005122 (2012).
  • Clifford G, Sameni R, Ward J, Robinson J, Wolfberg AJ. Clinically accurate fetal ECG parameters acquired from maternal abdominal sensors. Am. J. Obstet. Gynecol. 205, 47.e1–47.e5 (2011).
  • Cohen WR, Ommani S, Hassan S et al. Accuracy and reliability of fetal heart rate monitoring using maternal abdominal surface electrodes. Acta Obstet. Gynecol. Scand. 91, 1306–1313 (2012).
  • Becker JH, Bax L, Amer-Wahlin I et al. ST analysis of the fetal electrocardiogram in intrapartum fetal monitoring: a meta-analysis. Obstet. Gynecol. 119, 145–154 (2012).
  • Neilson JP. Fetal electrocardiogram (ECG) for fetal monitoring during labour. Cochrane Database Syst. Rev. 4, CD000116 (2012).
  • Euliano TY, Nguyen MT, Darmanjian S et al. Monitoring uterine activity during labor: a comparison of 3 methods. Am. J. Obstet. Gynecol. 208, 66 (2013).

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.