489
Views
27
CrossRef citations to date
0
Altmetric
Review

A wearable artificial kidney: technical requirements and potential solutions

, , , , , , & show all
Pages 567-579 | Published online: 09 Jan 2014

References

  • Ronco C, Davenport A, Gura V. Toward the wearable artificial kidney. Hemodial. Int.12(Suppl. 1), S40–S47 (2008).
  • Kjellstrand CM, Rosa AA, Shideman JR, Rodrigo F, Davin T, Lynch RE. Optimal dialysis frequency and duration: the ‘unphysiology hypothesis’. Kidney Int. Suppl. (8), S120–S124 (1978).
  • Heidenheim AP, Muirhead N, Moist L, Lindsay RM. Patient quality of life on quotidian hemodialysis. Am. J. Kidney Dis.42(1 Suppl.), 36–41 (2003).
  • Nesrallah G, Suri R, Moist L, Kortas C, Lindsay RM. Volume control and blood pressure management in patients undergoing quotidian hemodialysis. Am. J. Kidney Dis.42(1 Suppl.), 13–17 (2003).
  • Blaney TL, Lindan O, Sparks RE. Adsorption: a step toward a wearable artificial kidney. Trans. Am. Soc. Artif. Intern. Organs12, 7–12 (1966).
  • Blackshear PL Jr. Two new concepts that might lead to a wearable artificial kidney. Kidney Int. Suppl.8, S133–S137 (1978).
  • Jacobsen SC, Stephen RL, Bulloch EC, Luntz RD, Kolff WJ. A wearable artificial kidney: functional description of hardware and clinical results. Proc. Clin. Dial. Transplant. Forum5, 65–71 (1975).
  • Stephens RL, Jacobsen SC, Atkin-thor E, Kolff W. Portable/wearable artificial kidney (WAK) – initial evaluation. Proc. Eur. Dial. Transplant. Assoc.12, 511–518 (1976).
  • Brown CE, Kramer NC. Factors in membrane design and selection as a step toward a wearable artificial kidney. Trans. Am. Soc. Artif. Intern. Organs14, 36–42 (1968).
  • Neff MS, Sadjadi S, Slifkin R. A wearable artificial glomerulus. Trans. Am. Soc. Artif. Intern. Organs25, 71–73 (1979).
  • Bazzato G, Coli U, Landini S et al. A bag-filter model as machineless artificial kidney. Trans. Am. Soc. Artif. Intern. Organs29, 657–661 (1983).
  • Kolff WJ. Exponential growth and future of artificial organs. Artif. Organs1(1), 8–18 (1977).
  • Shaldon S, Beau MC, Claret G. Sorbent regeneration of ultrafiltrate as a long-term treatment of end-stage renal failure. Artif. Organs2(4), 343–347 (1978).
  • Shettigar UR, Kablitz C, Stephen R, Kolff WJ. A portable hemodialysis/hemofiltration system independent of dialysate and infusion fluid. Artif. Organs7(2), 254–256 (1983).
  • Murisasco A, Reynier JP, Ragon A et al. Continuous arterio-venous hemofiltration in a wearable device to treat end-stage renal disease. Trans. Am. Soc. Artif. Intern. Organs32(1), 567–571 (1986).
  • Popovich RP, Moncrief JW, Nolph KD, Ghods AJ, Twardowski ZJ, Pyle WK. Continuous ambulatory peritoneal dialysis. Ann. Intern. Med.88(4), 449–456 (1978).
  • Roberts M, Ash SR, Lee DBN. Innovative peritoneal dialysis: flow-thru and dialysate regeneration. ASAIO J.45(5), 372–378 (1999).
  • Lukowicz P, Kirstein T, Troster G. Wearable systems for health care applications. Methods Inf. Med.43(3), 232–238 (2004).
  • Rubel P, Fayn J, Simon-Chautemps L et al. New paradigms in telemedicine: ambient intelligence, wearable, pervasive and personalized. Stud. Health Technol. Inform.108, 123–132 (2004).
  • Gura V, Ronco C, Davenport A. The wearable artificial kidney, why and how: from holy grail to reality. Semin. Dial.22(1), 13–17 (2009).
  • Polaschegg HD. What is required for a WAK? Presented at: World Conference on Portable-Wearable and Miniaturized Systems for Dialysis and Ultrafiltration. Vicenza Italy, 30th September–1st October 2010.
  • Fissell WH, Roy S. The implantable artificial kidney. Semin. Dial.22(6), 665–670 (2009).
  • Morti SM, Zydney AL. Protein–membrane interactions during hemodialysis: effects on solute transport. ASAIO J.44(4), 319–326 (1998).
  • Huang Z, Gao D, Letteri JJ, Clark WR. Blood–membrane interactions during dialysis. Semin. Dial.22(6), 623–628 (2009).
  • Ronco C, Davenport A, Gura V. The future of the artificial kidney: moving towards wearable and miniaturized devices. Nefrologia31(1), 9–16 (2011).
  • Kim JC, Garzotto F, Cruz DN et al. Enhancement of solute removal in a hollow-fiber hemodialyzer by mechanical vibration. Blood Purif.31(4), 227–234 (2011).
  • Kim JC, Garzotto F, Chung SG, Ronco C. Effects of ambulation on hemodynamics of hollow-fiber hemodialyzer in the wearable artificial kidney. Presented at: World Conference on Portable-Wearable and Miniaturized Systems for Dialysis and Ultrafiltration. Vicenza, Italy, 30 September–1 October 2010.
  • Humes HD, MacKay SM, Funke AJ, Buffington DA. Tissue engineering of a bioartificial renal tubule assist device: in vitro transport and metabolic characteristics. Kidney Int.55(6), 2502–2514 (1999).
  • Humes HD, Weitzel WF, Bartlett RH et al. Initial clinical results of the bioartificial kidney containing human cells in ICU patients with acute renal failure. Kidney Int.66(4), 1578–1588 (2004).
  • Haase M, Bellomo R, Baldwin I et al. β2-microglobulin removal and plasma albumin levels with high cut-off hemodialysis. Int. J. Artif. Organs30(5), 385–392 (2007).
  • Leonard EF, West AC, Shapley NC, Larsen MU. Dialysis without membranes: how and why? Blood Purif.22(1), 92–100 (2004).
  • Nissenson AR, Ronco C, Pergamit G, Edelstein M, Watts R. The human nephron filter: Toward a continuously functioning, implantable artificial nephron system. Blood Purif.23(4), 269–274 (2005).
  • Weinberg E, Kaazempur-Mofrad M, Borenstein J. Concept and computational design for a bioartificial nephron-on-a-chip. Int. J. Artif. Organs31(6), 508–514 (2008).
  • Humes HD, Fissell WH, Tiranathanagul K. The future of hemodialysis membranes. Kidney Int.69(7), 1115–1119 (2006).
  • Fissell WH, Dubnisheva A, Eldridge AN, Fleischman AJ, Zydney AL, Roy S. High-performance silicon nanopore hemofiltration membranes. J. Memb. Sci.326(1), 58–63 (2009).
  • Chouard T. Structural biology: breaking the protein rules. Nature471(7337), 151–153 (2011).
  • Striemer CC, Gaborski TR, McGrath JL, Fauchet PM. Charge- and size-based separation of macromolecules using ultrathin silicon membranes. Nature445(7129), 749–753 (2007).
  • Gu Y, Miki N. Multilayered microfilter using a nanoporous PES membrane and applicable as the dialyzer of a wearable artificial kidney. J. Micromech. Microeng.19(6), 065031 (2009).
  • Gordon A, Better OS, Greenbaum MA, Marantz LB, Gral T, Maxwell MH. Clinical maintenance hemodialysis with a sorbent-based, low-volume dialysate regeneration system. Trans. Am. Soc. Artif. Intern. Organs17, 253–258 (1971).
  • Blagg CR, Vizzo JE, Jensen WB, Cole JJ. Experience with a sorbent-based dialysate regeneration system for hemodialysis. Prog. Biochem. Pharmacol.9, 239–248 (1974).
  • Blumenkrantz MJ, Gordon A, Roberts M. Applications of the Redy® sorbent system to hemodialysis and peritoneal dialysis. Artif. Organs3(3), 230–236 (1979).
  • Agar JWM. Review: understanding sorbent dialysis systems. Nephrology (Carlton)15(4), 406–411 (2010).
  • Giordano C, Esposito R, Bello P. Cold carbon apparatus for hemodialysis. J. Dial.1(2), 165–179 (1976).
  • Kim JH, Kim JC, Moon JH et al. Development of a cold dialysate regeneration system for home hemodialysis. Blood Purif.28(2), 84–92 (2009).
  • Tada Y, Horiuchi T, Ohta Y, Dohi T. A new approach for the filtrate regeneration system in the wearable artificial kidney. Artif. Organs14(6), 405–409 (1990).
  • Giordano C, Esposito R, Bello P, Quarto E. A resin-sorbent system for dialysate regeneration. Kidney Int.13(Suppl. 8), S138–S144 (1978).
  • Weber C, Rajnoch C, Loth F, Schima H, Falkenhagen D. The microspheres based detoxification system (MDS): a new extracorporeal blood purification technology based on recirculated microspherical adsorbent particles. Int. J. Artif. Organs17(11), 595–602 (1994).
  • Ash SR. Sorbents in treatment of uremia: a short history and a great future. Semin. Dial.22(6), 615–622 (2009).
  • Gura V, Macy AS, Beizai M, Ezon C, Golper TA. Technical breakthroughs in the wearable artificial kidney (WAK). Clin. J. Am. Soc. Nephrol.4(9), 1441–1448 (2009).
  • Gura V, Beizai M, Ezon C, Polaschegg HD. Continuous renal replacement therapy for end-stage renal disease. The wearable artificial kidney (WAK). Contrib. Nephrol.149, 325–333 (2005).
  • Boehm DA, Gottlieb PA, Hua SZ. On-chip microfluidic biosensor for bacterial detection and identification. Sens. Actuators B Chem.126(2), 508–514 (2007).
  • Walter A, Marz A, Schumacher W, Rosch P, Popp J. Towards a fast, high specific and reliable discrimination of bacteria on strain level by means of SERS in a microfluidic device. Lab Chip11(6), 1013–1021 (2011).
  • Vanholder R, Ringoir S. Pitfalls of wearable artificial kidney. Int. J. Artif. Organs13(11), 715–719 (1990).
  • Verhallen AM, Kooistra MP, van Jaarsveld BC. Cannulating in haemodialysis: rope-ladder or buttonhole technique? Nephrol. Dial. Transplant.22(9), 2601–2604 (2007).
  • Struthers J, Allan A, Peel RK, Lambie SH. Buttonhole needling of ateriovenous fistulae: a randomized controlled trial. ASAIO J.56(4), 319–322 (2010).
  • Trakarnvanich T, Chirananthavat T, Maneerat P, Chabsuwan S, Areeyakulnimit S. Is single-needle hemodialysis still a good treatment in end-stage renal disease? Blood Purif.25(5–6), 490–496 (2007).
  • Rostoker G, Griuncelli M, Loridon C, Bourlet T, Welsch K, Benmaadi A. Improving the efficiency of short-term single-needle hemodialysis. Ren. Fail.31(4), 261–266 (2009).
  • Beathard GA, Posen GA. Initial clinical results with the LifeSite Hemodialysis Access System. Kidney Int.58(5), 2221–2227 (2000).
  • Rosenblatt M, Caridi JG, Hakki FZ et al. Efficacy and safety results with the LifeSite hemodialysis access system versus the Tesio-Cath hemodialysis catheter at 12 months. J. Vasc. Interv. Radiol.17(3), 497–504 (2006).
  • Canaud B, My H, Morena M et al. Dialock: a new vascular access device for extracorporeal renal replacement therapy. Preliminary clinical results. Nephrol. Dial. Transplant.14(3), 692–698 (1999).
  • Quarello F, Forneris G, Formica M et al. Dialock® subcutaneous port for hemodialysis: a twelve-month experience in a single center. J. Vasc. Access2(2), 73–79 (2001).
  • Lee BH, Nam HY, Kwon T et al. Paclitaxel-coated expanded polytetrafluoroethylene haemodialysis grafts inhibit neointimal hyperplasia in porcine model of graft stenosis. Nephrol. Dial. Transplant.21(9), 2432–2438 (2006).
  • Avci-Adali M, Ziemer G, Wendel HP. Induction of EPC homing on biofunctionalized vascular grafts for rapid in vivo self-endothelialization – a review of current strategies. Biotechnol. Adv.28(1), 119–129 (2010).
  • Gould WR, Leadley RJ. Recent advances in the discovery and development of direct coagulation factor Xa inhibitors. Curr. Pharm. Des.9(28), 2337–2347 (2003).
  • Kubitza D, Becka M, Wensing G, Voith B, Zuehlsdorf M. Safety, pharmacodynamics, and pharmacokinetics of BAY 59–7939 – an oral, direct Factor Xa inhibitor – after multiple dosing in healthy male subjects. Eur. J. Clin. Pharmacol.61(12), 873–880 (2005).
  • Astapova EV, Stachura ME, Chernecky C, Rosenkoetter MM. Low-end videoconferencing for vascular access device site assessment in homecare. J. Assoc. Vasc. Access13(3), 135–138 (2008).
  • Eloot S, Dhondt A, Hoeben H, Vanholder R. Comparison of different methods to assess fistula flow. Blood Purif.30(2), 89–95 (2010).
  • Zeman HD, Lovhoiden G, Vrancken C. The clinical evaluation of vein contrast enhancement. Conf. Proc. IEEE Eng. Med. Biol. Soc.2, 1203–1206 (2004).
  • Kikuchi M, Hosokawa K. Visualized sclerotherapy of varicose veins. Dermatol. Surg.36(Suppl. 2), 1050–1055 (2010).
  • Heidenheim AP, Leitch R, Kortas C, Lindsay RM. Patient monitoring in the London Daily/Nocturnal Hemodialysis Study. Am. J. Kidney Dis.42(1 Suppl.), 61–65 (2003).
  • Gatzoulis L, Iakovidis I. Wearable and portable eHealth systems. Technological issues and opportunities for personalized care. IEEE Eng. Med. Biol. Mag.26(5), 51–56 (2007).
  • Lymberis A, Olsson S. Intelligent biomedical clothing for personal health and disease management: state of the art and future vision. Telemed. J. E. Health.9(4), 379–386 (2003).
  • Zheng JW, Zhang ZB, Wu TH, Zhang Y. A wearable mobihealth care system supporting real-time diagnosis and alarm. Med. Biol. Eng. Comput.45(9), 877–885 (2007).
  • Giansanti D, Macellari V, Maccioni G. Telemonitoring and telerehabilitation of patients with Parkinson’s disease: health technology assessment of a novel wearable step counter. Telemed. J. E. Health14(1), 76–83 (2008).
  • Connolly P, Cotton C, Morin F. Opportunities at the skin interface for continuous patient monitoring: a reverse iontophoresis model tested on lactate and glucose. IEEE Trans. Nanobioscience1(1), 37–41 (2002).
  • Sixsmith A, Hine N, Neild I, Clarke N, Brown S, Garner P. Monitoring the well-being of older people. Top. Geriatr. Rehabil.23(1), 9–23 (2007).
  • Hayes TL, Abendroth F, Adami A, Pavel M, Zitzelberger TA, Kaye JA. Unobtrusive assessment of activity patterns associated with mild cognitive impairment. Alzheimers Dement.4(6), 395–405 (2008).
  • Baek HJ, Lee HB, Kim JS, Choi JM, Kim KK, Park KS. Nonintrusive biological signal monitoring in a car to evaluate a driver’s stress and health state. Telemed. J. E. Health15(2), 182–189 (2009).
  • Rasouli M, Phee LSJ. Energy sources and their development for application in medical devices. Expert Rev. Med. Devices7(5), 693–709 (2010).
  • Takeuchi ES, Leising RA, Spillman DM et al. Lithium batteries for medical applications. In: Lithium Batteries: Science and Technology. Nazri G-A, Pistoia G (Eds). Springer, NY, USA, 686–700 (2003).
  • Peng B, Cheng F, Tao Z, Chen J. Lithium transport at silicon thin film: barrier for high-rate capability anode. J. Chem. Phys.133(3), 034701 (2010).
  • Nishide H, Oyaizu K. Materials science. Toward flexible batteries. Science319(5864), 737–738 (2008).
  • Davenport A, Gura V, Ronco C, Beizai M, Ezon C, Rambod E. A wearable haemodialysis device for patients with end-stage renal failure: a pilot study. Lancet370(9604), 2005–2010 (2007).
  • Kooman JP, Van Der Sande FM, Leunissen KML. The long road to wearable blood-cleansing devices. Blood Purif.25(4), 377–382 (2007).
  • Ronco C, Fecondini L. The vicenza wearable artificial kidney for peritoneal dialysis (ViWAK PD). Blood Purif.25(4), 383–388 (2007).
  • Lee DBN, Roberts M. A peritoneal-based automated wearable artificial kidney. Clin. Exp. Nephrol.12(3), 171–180 (2008).
  • Gura V, Ronco C, Nalesso F et al. A wearable hemofilter for continuous ambulatory ultrafiltration. Kidney Int.73(4), 497–502 (2008).
  • Fissell WH, Fleischman AJ, Humes HD, Roy S. Development of continuous implantable renal replacement: past and future. Transl. Res.150(6), 327–336 (2007).
  • Handley HH, Gorsuch R, Peters H et al. Slow continuous intravenous plasmapheresis (SCIP): clinical applications and hemostability of extracorporeal ultrafiltration. Contrib. Nephrol.149, 334–342 (2005).

Patents

  • Henne W. Artificial kidney. US 42127381978 (1980).
  • Gura V, Rambod E. Dual-ventricle pump cartridge, pump and method of use in a wearable continuous renal replacement therapy device. US 7855718 (2011).

Website

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.