146
Views
0
CrossRef citations to date
0
Altmetric
Original Research

Apexoconnection: A Novel Technique to Determine Working Length

ORCID Icon, , ORCID Icon, ORCID Icon &
Pages 353-360 | Published online: 17 Aug 2021

References

  • Vier-Pelisser FV, Meng A, Netto LCB, Só MVR. Influence of the instrumentation technique and apical preparation diameter on calcium hydroxide filling in simulated curved canals. Indian J Dental Res. 2012;23(6):784. doi:10.4103/0970-9290.111260
  • Dinapadu S, Pasari S, Admala SR, Marukala NR, Gurram S, Peddi R. Accuracy of electronic apex locator in enlarged root canals with different root canal irrigants: an in vitro study. J Contemp Dent Pract. 2013;14(4):649. doi:10.5005/jp-journals-10024-1379
  • Chaudhary S, Gharti A, Adhikari B. An in vivo comparison of accuracy of two electronic apex locators in determining working length using stainless steel and nickel titanium files. Clin Cosmet Investig Dent. 2018;10:75. doi:10.2147/CCIDE.S158882
  • Golvankar K, Kader MA, Latheef AA, Ali ABM, Abullais SS, Sibagathullah M. Comparison of accuracy in determining the root canal working length by using two generations of apex locators–an in vitro study. Open Access Macedonian j Med Sci. 2019;7(19):3276. doi:10.3889/oamjms.2019.696
  • Ricucci D, Langeland K. Apical limit of root canal instrumentation and obturation, part 2. A histological study. Int Endod J. 1998;31(6):394–409. doi:10.1046/j.1365-2591.1998.00183.x
  • Nekoofar M, Ghandi M, Hayes S, Dummer P. The fundamental operating principles of electronic root canal length measurement devices. Int Endod J. 2006;39(8):595–609. doi:10.1111/j.1365-2591.2006.01131.x
  • Burch JG, Hulen S. The relationship of the apical foramen to the anatomic apex of the tooth root. Oral Surg Oral Med Oral Pathol. 1972;34(2):262–268. doi:10.1016/0030-4220(72)90418-5
  • Saraswathi V, Kedia A, Purayil TP, Ballal V, Saini A. Comparative evaluation of the accuracy of two electronic apex locators in determining the working length in teeth with simulated apical root resorption: an in vitro study. J Conserv Dent. 2016;19(5):402–405. doi:10.4103/0972-0707.190002
  • Chugal NM, Clive JM, Spångberg LS. Endodontic infection: some biologic and treatment factors associated with outcome. Oral Surgery Oral Med Oral Pathol Oral Radiol Endodontol. 2003;96(1):81–90. doi:10.1016/S1079-2104(02)91703-8
  • Cianconi L, Angotti V, Felici R, Conte G, Mancini M. Accuracy of three electronic apex locators compared with digital radiography: an ex vivo study. J Endod. 2010;36(12):2003–2007. doi:10.1016/j.joen.2010.08.036
  • Guise GM, Goodell GG, Imamura GM. In vitro comparison of three electronic apex locators. J Endod. 2010;36(2):279–281. doi:10.1016/j.joen.2009.09.016
  • Karamifar K, Tondari A, Saghiri MA. Endodontic periapical lesion: an overview on the etiology, diagnosis and current treatment Modalities. Eur Endodontic J. 2020;5(2):54.
  • Seltzer S. Long-term radiographic and histological observations of endodontically treated teeth. J Endod. 1999;25(12):818–822. doi:10.1016/S0099-2399(99)80305-7
  • Santhosh L, Raiththa P, Aswathanarayana S, Panchajanya S, Reddy JT, Susheela SR. Influence of root canal curvature on the accuracy of an electronic apex locator: an in vitro study. J Conserv Dent. 2014;17(6):583–586. doi:10.4103/0972-0707.144610
  • Ravanshad S, Adl A, Anvar J. Effect of working length measurement by electronic apex locator or radiography on the adequacy of final working length: a randomized clinical trial. J Endod. 2010;36(11):1753–1756. doi:10.1016/j.joen.2010.08.017
  • ElAyouti A, Weiger R, Löst C. Frequency of overinstrumentation with an acceptable radiographic working length. J Endod. 2001;27(1):49–52. doi:10.1097/00004770-200101000-00018
  • ElAyouti A, Weiger R, Löst C. The ability of root ZX apex locator to reduce the frequency of overestimated radiographic working length. J Endod. 2002;28(2):116–119. doi:10.1097/00004770-200202000-00017
  • Vieyra J, Acosta J. Comparison of working length determination with radiographs and four electronic apex locators. Int Endod J. 2011;44(6):510–518. doi:10.1111/j.1365-2591.2011.01855.x
  • Dummer PM, Mcginn JH, Rees DG. The position and topography of the apical canal constriction and apical foramen. Int Endod J. 1984;17(4):192–198. doi:10.1111/j.1365-2591.1984.tb00404.x
  • Khattak O, Raidullah E, Francis ML. A comparative assessment of the accuracy of electronic apex locator (Root ZX) in the presence of commonly used irrigating solutions. J Clin Exp Dent. 2014;6(1):e41–6. doi:10.4317/jced.51230
  • Abdelsalam N, Hashem N. Impact of Apical patency on accuracy of electronic apex locators: in vitro study. J Endod. 2020;46(4):509–514. doi:10.1016/j.joen.2020.01.010
  • Plotino G, Grande N, Brigante L, Lesti B, Somma F. Ex vivo accuracy of three electronic apex locators: root ZX, elements diagnostic unit and apex locator and propex. Int Endod J. 2006;39(5):408–414. doi:10.1111/j.1365-2591.2006.01095.x
  • Stein TJ, Corcoran JF. Radiographic “working length” revisited. Oral Surgery Oral Med Oral Pathol. 1992;74(6):796–800. doi:10.1016/0030-4220(92)90412-J
  • Hassanien EE, Hashem A, Chalfin H. Histomorphometric study of the root apex of mandibular premolar teeth: an attempt to correlate working length measured with electronic and radiograph methods to various anatomic positions in the apical portion of the canal. J Endod. 2008;34(4):408–412. doi:10.1016/j.joen.2007.12.013
  • Regan JE. Endodontic file with a metallic conductor as part of the plastic handle to facilitate use of electronic apex locators. Google Patents. 2005.
  • Langbein S, Storch R. Apex locator attachment. Google Patents. 2019.
  • Morita J, Corp K. DentaPort zx operation instructions. 2018.
  • Uğur Aydin Z, Göller Bulut D. Determination of root canal length up to perforation area using different electronic apex locators and cbct images obtained at different voxel sizes: a comparative ex vivo study. Chin J Dent Res. 2021;24(1):49–54. doi:10.3290/j.cjdr.b1105877
  • de Camargo EJ, Zapata RO, Medeiros PL, et al. Influence of preflaring on the accuracy of length determination with four electronic apex locators. J Endod. 2009;35(9):1300–1302. doi:10.1016/j.joen.2009.05.030
  • Baldi JV, Victorino FR, Bernardes RA, et al. Influence of embedding media on the assessment of electronic apex locators. J Endod. 2007;33(4):476–479. doi:10.1016/j.joen.2006.12.024
  • Swapna DV, Krishna A, Patil AC, Rashmi K, Pai VS, Ranjini MA. Comparison of third generation versus fourth generation electronic apex locators in detecting apical constriction: an in vivo study. J Conserv Dent. 2015;18(4):288–291. doi:10.4103/0972-0707.159726
  • Guerreiro-Tanomaru JM, Croti HR, Silva GF, Faria G, Tanomaru-Filho M. Tooth embedding medium influences the accuracy of electronic apex locator. Acta Odontol Latinoam. 2012;25(2):214–217.
  • Ebrahim AK, Yoshioka T, Kobayashi C, Suda H. The effects of file size, sodium hypochlorite and blood on the accuracy of Root ZX apex locator in enlarged root canals: an in vitro study. Aust Dent J. 2006;51(2):153–157. doi:10.1111/j.1834-7819.2006.tb00419.x