56
Views
8
CrossRef citations to date
0
Altmetric
Original Research

Central corneal thickness and anterior chamber depth measurement by Sirius® Scheimpflug tomography and ultrasound

, , &
Pages 417-422 | Published online: 26 Feb 2013

References

  • ParafitaMAGonzalez-MeijomeJMDiaz-ReyJACorneal thickness mapping by topographical ultrasonic pachymetryInt Contact Lens Clin2000271221
  • ParafitaMYebra-PimentelEGiraldezMJFurther information on the knowledge of topographical corneal thicknessInt Contact Lens Clin19992612813711166139
  • CervinoAGonzalez-MeijomeJMFerrer-BlascoTDetermination of corneal volume from anterior topography and topographic pachymetry: application to healthy and keratoconic eyesOphthalmic Physiol Opt20092965266019821928
  • ReinsteinDZArcherTJGobbeMStromal thickness in the normal cornea: three-dimensional display with Artemis very high-frequency digital ultrasoundJ Refract Surg20092577678619772263
  • WadaIUltrasound biomicroscopic corneal thickness measurement for corneal thickness mappingJpn J Ophthalmol19974112189147182
  • Gonzalez-MeijomeJMCervinoAYebra-PimentelEParafitaMACentral and peripheral corneal thickness measurement with Orbscan II and topographical ultrasound pachymetryJ Cataract Refract Surg20032912513212551679
  • YaziciATBozkurtEAlagozCCentral corneal thickness, anterior chamber depth, and pupil diameter measurements using Visante OCT, Orbscan, and PentacamJ Refract Surg20102612713320163077
  • Gonzalez-PerezJGonzalez-MeijomeJMRodriguez AresMTParafitaMACentral corneal thickness measured with three optical devices and ultrasound pachometryEye Contact Lens201137667021301351
  • LacknerBSchmidingerGPiehSRepeatability and reproducibility of central corneal thickness measurement with Pentacam, Orbscan, and ultrasoundOptom Vis Sci20058289289916276321
  • HoTChengACRaoSKCentral corneal thickness measurements using Orbscan II, Visante, ultrasound, and Pentacam pachymetry after laser in situ keratomileusis for myopiaJ Cataract Refract Surg2007331177118217586372
  • Gonzalez-PerezJGonzalez-MeijomeJMRodriguez AresMTParafitaMATopographic paracentral corneal thickness with pentacam and orbscan: effect of acoustic factorEye Contact Lens20113734835321983548
  • AlfonsoJFFerrer-BlascoTGonzalez-MeijomeJMPupil size, white-to-white corneal diameter, and anterior chamber depth in patients with myopiaJ Refract Surg20102689189820027985
  • HashemiHYazdaniKMehravaranSFotouhiAAnterior chamber depth measurement with a-scan ultrasonography, Orbscan II, and IOLMasterOptom Vis Sci20058290090416276322
  • SaviniGBarboniPCarbonelliMHofferKJRepeatability of automatic measurements by a new Scheimpflug camera combined with Placido topographyJ Cataract Refract Surg2011371809181621852068
  • SaviniGCarbonelliMSbregliaAComparison of anterior segment measurements by 3 Scheimpflug tomographers and 1 Placido corneal topographerJ Cataract Refract Surg2011371679168521855765
  • MillaMPineroDPAmparoFAlioJLPachymetric measurements with a new Scheimpflug photography-based system: intraobserver repeatability and agreement with optical coherence tomography pachymetryJ Cataract Refract Surg20113731031621241914
  • DuTRVegaJAFonnDSimpsonTDiurnal variation of corneal sensitivity and thicknessCornea20032220520912658083
  • BlandJMAltmanDGStatistical methods for assessing agreement between two methods of clinical measurementLancet198613073102868172
  • NamSMImCYLeeHKKimEKKimTISeoKYAccuracy of RTVue optical coherence tomography, Pentacam, and ultrasonic pachymetry for the measurement of central corneal thicknessOphthalmology20101172096210320557940
  • HashemiHMehravaranSRezvanFChanges in corneal thickness, curvature, and anterior chamber depth during the menstrual cycleCan J Ophthalmol201045677020130714
  • ModisLSzalaiENémethGBertaAReliability of the corneal thickness measurements with the Pentacam HR imaging system and ultrasound pachymetryCornea20113056156621139499
  • NemethGVajasAKolozsvariBBertaAModisLAnterior chamber depth measurements in phakic and pseudophakic eyes: Pentacam versus ultrasound deviceJ Cataract Refract Surg2006321331133516863970