References
- HofferKJShammasHJSaviniGComparison of 2 laser instruments for measuring axial lengthJ Cataract Refract Surg201036464464820362858
- OlsenTSources of error in intraocular lens power calculationJ Cataract Refract Surg19921821251291564648
- DrexlerWFindlOMenapaceRPartial coherence interferometry: a novel approach to biometry in cataract surgeryAm J Ophthalmol199812645245349780097
- KissBFindlOMenapaceRBiometry of cataractous eyes using partial coherence interferometry: clinical feasibility study of a commercial prototype IJ Cataract Refract Surg200228222422911821200
- KissBFindlOMenapaceRRefractive outcome of cataract surgery using partial coherence interferometry and ultrasound biometry: clinical feasibility study of a commercial prototype IIJ Cataract Refract Surg200228223023411821201
- ConnorsRBosemanPOlsonRJAccuracy and reproducibility of biometry using partial coherence interferometryJ Cataract Refract Surg200228223523811821202
- RajanMSKeilhornIBellJAPartial coherence laser interferometry vs conventional ultrasound biometry in intraocular lens power calculationsEye (Lond)200216555255612194067
- EleftheriadisHIOLMaster biometry: refractive results of 100 consecutive casesBr J Ophthalmol200387896096312881334
- OlsenTImproved accuracy of intraocular lens power calculation with the Zeiss IOLMasterActa Ophthalmol Scand2007851848717244216
- VogelADickHBKrummenauerFReproducibility of optical biometry using partial coherence interferometry: intraobserver and interobserver reliabilityJ Cataract Refract Surg200127121961196811738911
- NémethJFeketeOPesztenlehrerNOptical and ultrasound measurement of axial length and anterior chamber depth for intraocular lens power calculationJ Cataract Refract Surg2003291858812551672
- LamAKChanRPangPCThe repeatability and accuracy of axial length and anterior chamber depth measurements from the IOLMasterOphthalmic Physiol Opt200121647748311727876
- FindlOKriechbaumKSacuSInfluence of operator experience on the performance of ultrasound biometry compared to optical biometry before cataract surgeryJ Cataract Refract Surg200329101950195514604716
- SiahmedKMuraineMBrasseurGOptic biometry in intraocular lense calculation for cataract surgery. Comparison with usual methodsJ Fr Ophtalmol2001249922926 French11912834
- PackerMFineIHHoffmanRSCoffmanPGBrownLKImmersion A-scan compared with partial coherence interferometry: outcomes analysisJ Cataract Refract Surg200228223924211821203
- ShammasHJChanSPrecision of biometry, keratometry, and refractive measurements with a partial coherence interferometry-keratometry deviceJ Cataract Refract Surg20103691474147820692557
- RabsilberTMJepsenCAuffarthGUHolzerMPIntraocular lens power calculation: clinical comparison of 2 optical biometry devicesJ Cataract Refract Surg201036223023420152602
- BuckhurstPJWolffsohnJSShahSNarooSADaviesLNBerrowEJA new optical low coherence reflectometry device for ocular biometry in cataract patientsBr J Ophthalmol200993794995319380310
- HolzerMPMamusaMAuffarthGUAccuracy of a new partial coherence interferometry analyser for biometric measurementsBr J Ophthalmol200993680781019289385
- HillWAngelesROtaniTEvaluation of a new IOLMaster algorithm to measure axial lengthJ Cataract Refract Surg200834692092418498996
- ChylackLTWolfeJKSingerDMThe Lens Opacities Classification System III. The Longitudinal Study of Cataract Study GroupArch Ophthalmol199311168318368512486
- TehraniMKrummenauerFBlomEDickHBEvaluation of the practicality of optical biometry and applanation ultrasound in 253 eyesJ Cataract Refract Surg200329474174612686242
- FreemanGPesudovsKThe impact of cataract severity on measurement acquisition with the IOLMasterActa Ophthalmol Scand200583443944216029267