3,850
Views
80
CrossRef citations to date
0
Altmetric
Review

New developments in prosthetic arm systems

, &
Pages 31-39 | Published online: 07 Jul 2016

References

  • NiskaRBhuiyaFXuJNational Hospital Ambulatory Medical Care Survey: 2007 emergency department summaryNatl Health Stat Report. 201026131 Available from: http://www.ncbi.nlm.nih.gov/pubmed/20726217Accessed June 1, 2016
  • OotesDLambersKTRingDCThe epidemiology of upper extremity injuries presenting to the emergency department in the United StatesHand (N Y)201271182223449400
  • LarsenCFMulderSJohansenAMStamCThe epidemiology of hand injuries in the Netherlands and DenmarkEur J Epidemiol200419432332715180102
  • U.S. Department of Labor, Bureau of Labor StatisticsWork Related Hand Injuries and Upper Extremity Amputation0073Washington, DCU.S. Department of Labor1982 Bulletin 2
  • KahnAPThe Encyclopedia of Work-Related Hand Injuries and Upper Extremity AmputationsNew York, NYFacts on File2004
  • RettigACAthletic injuries of the wrist and handAm J Sports Med200432126227314754754
  • GrunertBKSmithrJSDevineCAEarly psychological aspects of severe hand injuryJ Hand Surg Am198813-B2177180
  • GrobMPapadopulosNAZimmermannABiemerEKovacsLThe psychological impact of severe hand injuryJ Hand Surg Eur Vol200833335836218450795
  • PuttiVHistorical ProsthesesJ Hand Surg200530310325
  • MerrillDRLockhartJTroykPRWeirRFHankinDLDevelopment of an implantable myoelectric sensor for advanced prosthesis controlArtif Organs201135324925221371058
  • ChildressDHistorical aspects of powered limb prosthesesClin Prosthet Orthot198591213
  • MarquardtEThe Heidelberg pneumatic arm prosthesisJ Bone Jt1965473425
  • BiddissEChauTUpper-limb prosthetics: critical factors in device abandonmentAm J Phys Med Rehabil2007861297798718090439
  • PylatiukCSchulzSDöderleinLResults of an Internet survey of myoelectric prosthetic hand usersProsthet Orthot Int200731436237018050007
  • EgermannMKastenPThomsenMMyoelectric hand prostheses in very young childrenInt Orthop20093341101110518636257
  • McFarlandLVHubbard WinklerSLHeinemannAWJonesMEsquenaziAUnilateral upper-limb loss: satisfaction and prosthetic-device use in veterans and servicemembers from Vietnam and OIF/OEF conflictsJ Rehabil Res Dev201047429931620803400
  • ØstlieKLesjøIMFranklinRJGarfeltBSkjeldalOHMagnusPProsthesis rejection in acquired major upper-limb amputees: a population-based surveyDisabil Rehabil Assist Technol20127429430322112174
  • SilcoxHRooksMVogelRRFlemingLLMyoelectric prostheses. A long-term follow-up and a study of the use of alternate prosthesesJ Bone Joint Surg Am19937512178117898258548
  • BurroughSFBrookJAPatterns of acceptance and rejection of upper limb prosthesesOrthot Prosthet19853924047
  • GlynnMGalwayHHunterGSauterWManagement of the upper-limb-deficient child with a powered prosthetic deviceCurr Orthop Pract1986209202205
  • JonesJWGruberSABarkerJHBreidenbachWCSuccessful hand transplantation one-year follow-upN Engl J Med2000343746847310950668
  • SalmingerSSturmaARocheA[Hand function after hand transplant and prosthetic reconstruction] Handfunktion nach Handtransplantation und prothetischer Rekonstruktion38 Seminar – Surgery meets Biomedical Engineering. Austrian Society for Surgical ResearchWagrain, Austria2014
  • Vincent Systems [webpage on the Internet]Vincent Evolution 22016 Available from: www.vincentsystems.de/en/prosthetics/vincent-evolution-2/Accessed June 21, 2016
  • ResnikLKlingerSLEtterKThe DEKA arm: its features, functionality, and evolution during the veterans affairs study to optimize the DEKA armProsthet Orthot Int201438649250424150930
  • ResnikLKlingerSLEtterKUser and clinician perspectives on DEKA arm: results of VA study to optimize DEKA armJ Rehabil Res Dev2014511273824805891
  • SearsHHIversenEArcherSJacobsTWrist innovations to improve function of electric terminal devicesProc 2008 MyoElectric Control Prosthetics Symp20081316
  • BennettDAMitchellJGoldfarbMDesign and characterization of a powered elbow prosthesis2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC). IEEE201524582461
  • LipschutzRDKuikenTAMillerLADumanianGAStubblefieldKAOtrLShoulder disarticulation externally powered prosthetic fitting following targeted muscle reinnervation for improved myoelectric controlProsthet Orthot Int2006182245253
  • FDA [webpage on the Internet]FDA allows marketing of first prosthetic arm that translates signals from person’s muscles to perform complex tasks Available from: http://www.fda.gov/NewsEvents/Newsroom/PressAnnouncements/ucm396688.htmAccessed February 24, 2016
  • LakeCThe evolution of upper limb prosthetic socket designJPO J Prosthet Orthot200820385
  • DalyWVooLRosenbaum-ChouTArabianABooneDSocket pressure and discomfort in upper-limb prostheses: a preliminary studyJPO J Prosthet Orthot201426299106
  • BiddissEAChauTTUpper limb prosthesis use and abandonment: a survey of the last 25 yearsProsthet Orthot Int200731323625717979010
  • HeppOKuhnGGUpper extremity prosthesesProsthetics International, Proceedings of the Second International Prosthetics Course. Committee on Prosthetics, Braces, and Technical Aids, International Society for the Welfare of CripplesCopenhagen, Denmark1960133181
  • BillockJNThe Northwestern University supracondylar suspension technique for below-elbow amputationsOrthot Prosthet19722641623
  • UellendahlJERamdialSCustom silicone sockets for myoelectric prosthesesMEC ’05 Intergrating Prosthetics and Medicine Proceedings of the 2005 MyoElectric Controls/Powered Prosthetics SymposiumFredericton, NB20052124
  • AlleyRDAdvancement of upper extremity prosthetic interface and frameMEC ’02 The Next Generation Proceedings of the 2002 MyoElectric Controls/Powered Prosthetics SymposiumFredericton, NB2002
  • BranemarkPIOsseointegration and its experimental backgroundJ Prosthet Dent19835033994106352924
  • BrånemarkRBrånemarkP-IRydevikBMyersRROsseointegration in skeletal reconstruction and rehabilitation: a reviewJ Rehabil Res Dev200138217518111392650
  • TjellstromALindstromJHallenOAlbrektssonTBrånemarkP-IOsseointegrated titanium implants in the temporal bone. A clinical study on bone-anchored hearing aidsAm J Otol1981243043106894824
  • BrånemarkP-IChienSThe Osseointegration Book: From Calvarium to CalcaneusHanover Park, ILQuintessence Publishing Company2005
  • JönssonSCaine-WinterbergerKBrånemarkROsseointegration amputation prostheses on the upper limbs: methods, prosthetics and rehabilitationProsthet Orthot Int201135219020021697201
  • GallagherPDesmondDMacLachlanMPsychoprostheticsBerlinSpringer-Verlag2007
  • KlinebergIMurrayGOsseoperception: sensory function and proprioceptionAdv Dent Res19991312012911276734
  • ZuoKJOlsonJLThe evolution of functional hand replacement: from iron prostheses to hand transplantationCan J Plast Surg20142214451
  • SheltonTJBeckPJBloebaumRDBachusKNPercutaneous Osseo-integrated prostheses for amputees: limb compensation in a 12-month ovine modelJ Biomech201144152601260621920525
  • WeirRFFTroykPRRDeMicheleGKuikenTKuTImplantable myoelectric sensors (IMES) for upper-extremity prosthesis control-preliminary workProc 25th Annu Int Conf IEEE Eng Med Biol Soc. IEEECancun, Mexico2003215621565
  • WeirRTroykPDemicheleGKernsDTechnical details of the implantable myoelectric sensor (IMES) system for multifunction prosthesis controlConf Proc IEEE Eng Med Biol Soc200577337734017281975
  • MuceliSPoppendieckWNegroFAccurate and representative decoding of the neural drive to muscles in humans with multi-channel intramuscular thin-film electrodesJ Physiol2015593173789380426174910
  • CiprianiCSegilJLBirdwellJAWeirRFDexterous control of a prosthetic hand using fine-wire intramuscular electrodes in targeted extrinsic musclesIEEE Trans Neural Syst Rehabil Eng201422482883624760929
  • FarnsworthBDTalyorDMTrioloRJYoungDJWireless in vivo EMG sensor for intelligent prosthetic controlTRANSDUCERS 2009 – 15th Int Conf Solid-State Sensors, Actuators Microsystems. IEEEDenver, CO, USA2009358361
  • MiceraSNavarroXCarpanetoJOn the use of longitudinal intrafascicular peripheral interfaces for the control of cybernetic hand prostheses in amputeesIEEE Trans Neural Syst Rehabil Eng200816545347218990649
  • ScottRNParkerPAMyoelectric prostheses: state of the artJ Med Eng Technol19881241431513057209
  • SteeperRSLBeBionic v3 Product BrochureLeedsRSL Steeper2013
  • Otto Bock Healthcare GmbHFDA 510(k) Premarket Notification: Summary Axon-Bus Prosthetic SystemSilver Spring, MDOtto Bock Healthcare GmbH2014 20993-0002
  • WilliamsTW3rdPractical methods for controlling powered upper-extremity prosthesesAssist Technol19902131810149040
  • SteeperRSLUpper Limb Prosthetic Components – Technical Product BrochureLeedsRSL Steeper2014
  • Touch Bionics [webpage on the Internet]How the i-limb works Available from: http://www.touchbionics.com/products/how-i-limb-worksAccessed April 29, 2016
  • Touch BionicsBiosim-i My i-limb DatasheetMansfield, MATouch Bionics2014
  • Otto Bock Healthcare GmbHMichelangelo Technican Product BrochureDuderstadtOtto Bock Healthcare GmbH2013
  • Touch Bionics [webpage on the Internet]i-limb QR codes Available from: http://www.touchbionics.com/resources/qr-codesAccessed April 29, 2016
  • Touch BionicsGrip Chips – Product OverviewMansfield, MATouch Bionics2015
  • HudginsBParkerPScottRNA new strategy for multifunction myoelectric controlIEEE Trans Biomed Eng199340182948468080
  • GraupeDSalahiJKohnKHMultifunctional prosthesis and orthosis control via microcomputer identification of temporal pattern differences in single-site myoelectric signalsJ Biomed Eng19824117227078136
  • Coapt LLC [homepage on the Internet]Coapt Engineering2016 Available from: http://www.coaptengineering.com/Accessed April 29, 2016
  • YoungAJHargroveLJKuikenTAThe effects of electrode size and orientation on the sensitivity of myoelectric pattern recognition systems to electrode shiftIEEE Trans Biomed Eng20115892537254421659017
  • HargroveLEnglehartKHudginsBA training strategy to reduce classification degradation due to electrode displacements in pattern recognition based myoelectric controlBiomed Signal Process Control200832175180
  • StangoANegroFFarinaDSpatial correlation of high density EMG signals provides features robust to electrode number and shift in pattern recognition for myocontrolIEEE Trans Neural Syst Rehabil Eng201523218919825389242
  • Ortiz-CatalanMBrånemarkRHåkanssonBDelbekeJOn the viability of implantable electrodes for the natural control of artificial limbs: review and discussionBiomed Eng Online20121113322715940
  • RocheADRehbaumHFarinaDAszmannOCProsthetic myoelectric control strategies: a clinical perspectiveCurr Surg Rep20142344
  • JiangNDosenSFarinaD webpage on the InternetMyoelectric control of artificial limbs: is there the need for a change of focus?IEEE Signal Process Mag20121215 Available from: http://www.lifesciences.ieee.org/articles/174-myoelectric-control-of-artificial-limbs-is-there-a-need-to-change-focusAccessed June 27, 2013
  • JiangNEnglehartKBParkerPAExtracting simultaneous and proportional neural control information for multiple-DOF prostheses from the surface electromyographic signalIEEE Trans Biomed Eng20095641070108019272889
  • JiangNRehbaumHVujaklijaIGraimannBFarinaDIntuitive, online, simultaneous, and proportional myoelectric control over two degrees-of-freedom in upper limb amputeesIEEE Trans Neural Syst Rehabil Eng201422350151023996582
  • JiangNVujaklijaIRehbaumHGraimannBFarinaDIs accurate mapping of EMG signals on kinematics needed for precise online myoelectric control?IEEE Trans Neural Syst Rehabil Eng201422354955824235278
  • HofmannDJiangNVujaklijaIFarinaDBayesian filtering of surface EMG for accurate simultaneous and proportional prosthetic controlIEEE Trans Neural Syst Rehabil Eng Epub201511201
  • IsonMVujaklijaIWhitsellBFarinaDArtemiadisPHigh-density electromyography and motor skill learning for robust long-term control of a 7-DoF robot armIEEE Trans Neural Syst Rehabil Eng201624442443325838524
  • AmsuessSVujaklijaIGobelPContext-dependent upper limb prosthesis control for natural and robust useIEEE Trans Neural Syst Rehabil Eng Epub2015791
  • RocheADVujaklijaIAmsuessSStructured rehabilitation training for improved multifunctional prosthetic control : a case studyJ Vis Exp2015105e52968
  • DederichRPlastic treatment of the muscles and bone in amputation surgery a method designed to produce physiological conditions in the stumpJ Bone Joint Surg Am196345B6066
  • LieberRLSkeletal muscel architecture implications for muscle function and surgical tendon transferJ Hand Ther1993621051138343877
  • CooneyWPLinscheidRLAnKNOpposition of the thumb: an anatomic and biomechanical study of tendon transfersJ Hand Surg Am1984967777866512185
  • MayJWGordonLPalm of hand free flap for forearm length preservation in nonreplantable forearm amputation: a case reportJ Hand Surg Am1980543773807419882
  • UlusalBGLinY-TUlusalAELinC-HFree lateral arm flap for 1-stage reconstruction of soft tissue and composite defects of the hand: a retrospective analysis of 118 casesAnn Plast Surg200758217317817245144
  • BrandtKKhouriRKUptonJFree flaps as flow-through vascular conduits for simultaneous coverage and revascularization of the hand or digitPlast Reconstr Surg19969823213278764721
  • NeumeisterMHeggeTAmalfiASauerbierMThe reconstruction of the mutilated handSemin Plast Surg20102417710221286307
  • BlairVPByarsLTToe to finger transplantAnn Surg194011228729017857641
  • MorrisonWAO’BrienBMacLeodAMRing finger transfer in reconstruction of transmetacarpal amputationsJ Hand Surg Am19849A14116693742
  • FoucherGMossALHMicrovascular second toe to finger transfer: a statistical analysis of 55 transfersBr J Plast Surg199144287902018911
  • CantyTJBleckEESplit-thickness skin grafting of amputation stumpsPlast Reconstr Surg195210299115
  • WoodMRHunterGAMillsteinSGThe value of stump split skin grafting following amputation for trauma in adult upper and lower limb amputeesProsthet Orthot Int198711271743309883
  • KuikenTADumanianGALipschutzRDMillerLAStubblefieldKAThe use of targeted muscle reinnervation for improved myoelectric prosthesis control in a bilateral shoulder disarticulation amputeeProsthet Orthot Int200428324525315658637
  • HofferJLoebGImplantable electrical and mechanical interfaces with nerve and muscleAnn Biomed Eng1980843513607027837
  • KuikenTALiGLockBATargeted muscle reinnervation for real-time myoelectric control of multifunction artificial armsJAMA2009301661962819211469
  • AszmannOCRocheADSalmingerSBionic reconstruction to restore hand function after brachial plexus injury : a case series of three patientsLancet201538599832183218925724529
  • Hosmer Dorrance CorporationHosmer Upper Extremity Product Catalog2012 Available from: http://hosmer.com/products/PDFs/Fil-lauer Product Catalog.pdfAccessed June 1, 2016
  • Hosmer Dorrance CorporationHooks, Hands, and Wrists – Product Brochure2003158 Available from: http://hosmer.com/products/book3/pdfs/2-HooksHandsWrists.pdfAccessed June 1, 2016
  • Otto Bock Healthcare GmbHUpper Limb Prosthetics Catalog4DuderstadtOtto Bock Healthcare GmbH2014177184
  • Liberating Technologies IncSelect Electric Hands for Adults Product CatalogHolliston, MALiberating Technologies Inc2013
  • Liberating Technologies Inc [homepage on the Internet]Select Electric Hands & Gloves Data Sheet2010 Available from: http://www.liberatingtech.com/products/documents/LTI_Data_Sheet_-_Electric_Hands_&_Wrists.pdfAccessed June 21, 2016
  • Touch Bionicsi-Limb Quantum Clinician ManualMansfield, MATouch Bionics2015MA 01333 Issue No 1
  • Touch Bionicsi-Limb Quantum User Manual201511121 Available from: http://www.touchbionics.com/sites/default/files/files/i-limb quantum user manual July 2015.pdfAccessed June 1, 2016
  • Touch Bionicsi-Limb Quantum Product SheetMansfield, MATouch Bionics201512
  • Touch BionicsFlexion Wrist Product SheetMansfield, MATouch Bionics201512
  • FillauerUtah Arm 3 Plus Sales SheetChattanooga, TNFillauer2012
  • HussainIMasoodAIqbalJKhanUSDesign of high torque elbow joint for above elbow prosthesisInt J Mech Aerosp Ind Mechatron Eng2011511318321
  • Boston DigitalBoston Digital Arm System CatalogAucklandBoston Digital2013
  • Otto Bock Healthcare GmbHElbow Components – At a GlanceDuderstadtOtto Bock Healthcare GmbH2014
  • Hosmer Dorrance Corporation Externally Powered Systems Product CatalogCampbell, CA201518 Available at: http://hosmer.com/products/book3/pdfs/4-ExternallyPoweredSystems.pdfAccessed June 21, 2016